Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Servomotor |
|
1PH4 |
|
Cooling |
Water cooling |
Coolant inlet temperature |
Because of the formation of condensation, we recommend a coolant inlet temperature of approx. 30 °C (86 °F), depending on the ambient conditions. |
Cooling water pressure at inlet, max. |
7 bar |
Temperature monitoring |
2 KTY 84 temperature sensors in the stator winding, |
Insulation of the stator winding in accordance with EN 60034 1 (IEC 60034 1) |
Temperature class 155 (F) for a coolant inlet temperature of up to 30 °C (86 °F) |
Encoder system, built-in |
|
|
|
|
|
Type of construction in accordance with EN 60034 7 (IEC 60034 7) |
IM B35 (IM V15, IM V35) |
Terminal box location
|
Top, rotatable 4 90° |
Terminal box connection type |
|
|
Terminals in terminal box |
|
12-pin/17-pin circular socket (without mating connector) or DRIVE-CLiQ |
Bearing version on DE2) |
Duplex bearing for belt or coupling output (minimum cantilever force required) |
Vibration magnitude in accordance with EN 60034 14 (IEC 60034 14) |
Grade R (reduced) |
Shaft and flange accuracy in accordance with DIN 42955 (IEC 60072 1)3) |
Tolerance N (normal) |
Shaft extension DE in accordance with DIN 748 3 (IEC 60072 1) |
Full-key balancing with keyway |
Degree of protection in accordance with EN 60034 5 (IEC 60034 5) |
IP65, IP55 on shaft exit |
Sound pressure level
L
pA
(1 m) in accordance with EN ISO 1680
|
|
|
69 dB |
|
71 dB |
Paint finish |
Anthracite |
Approvals, according to |
cURus |
S/R = signals/revolution
Refer to Liquid cooling for a list of heat exchanger manufacturers.
1) DE is the drive end with shaft. NDE is the non-drive end.
2) For maximum permissible load, see the 1PH4 Motors Configuration Manual.
3) Shaft extension run-out, concentricity of centering ring and shaft, and perpendicularity of flange to shaft.