Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Order No. |
6GK5 408-2FD00-2AA2 |
6GK5 414-3FC00-2AA2 |
Product type designation |
SCALANCE X408-2 |
SCALANCE X414-3E |
Transmission rate |
||
Transfer rate 1 |
10 Mbit/s |
10 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
100 Mbit/s |
Transfer rate 3 |
1 000 Mbit/s |
1 000 Mbit/s |
Interfaces |
||
Number of electrical/optical connections for network components or terminal equipment maximum |
12 |
26 |
Number of electrical connections for operator console |
1 |
1 |
Design of electrical connection for operator console |
RS232 port |
RS232 port |
Number of electrical connections |
||
|
8 |
14 |
|
- |
8 |
|
1 |
1 |
|
2 |
3 |
|
1 |
1 |
|
1 |
1 |
Design of electrical connection |
||
|
RJ45 port (4 x 1GE, 4 x FE) |
RJ45 port (2 x 1GE, 12 x FE) |
|
- |
RJ45 port via EM495-8 |
|
4-pole terminal block |
4-pole terminal block |
|
4-pole terminal block |
4-pole terminal block |
Number of optical interfaces for optical waveguide |
||
|
4 |
4 |
|
4 |
2 |
|
- |
8 |
Design of optical interface for optical waveguide |
||
|
BFOC or SC ports via media modules MM491-2, MM491-2LD, MM491-2LH+ |
BFOC or SC ports via media modules MM491-2, MM491-2LD, MM491-2LH+ |
|
SC ports via media modules MM492-2, MM492-2LD, MM492-2LH, MM492-2LH+ |
SC ports via media modules MM492-2, MM492-2LD, MM492-2LH, MM492-2LH+ |
|
- |
BFOC or SC ports via media modules MM491-2, MM491-2LD, MM491-2LH+, MM492-2, MM492-2LD, MM492-2LH, MM492-2LH+ |
Connectable optical power relative to 1 mW |
||
|
- - |
- - |
|
- |
- |
Optical sensitivity relative to 1 mW of the receiver input minimum |
- |
- |
Attenuation of fiber-optic cable transmission link minimum necessary |
- |
- |
Range at the optical interface depending on the optical fiber used |
- - |
- - |
Number of extender expansion interfaces |
- |
1 |
design of the extender extension interface |
- |
EM495-8 or EM496-4 |
design of the removable storage C-PLUG |
Yes |
Yes |
Inputs/outputs |
||
Operating current of signaling contacts at AC maximum |
- |
- |
Operating voltage of signaling contacts at DC rated value |
24 V |
24 V |
Operating current of signaling contacts at DC maximum |
0.1 A |
0.1 A |
Number of digital inputs |
- |
2 |
Number of electrical connections for digital input signals |
- |
2 |
Design of electrical connection for digital input signals |
- |
5-pole terminal block |
Supply voltage, current consumption, power loss |
||
Type of voltage of supply voltage |
DC |
DC |
Supply voltage external |
24 V |
24 V |
|
20.4 V |
20.4 V |
|
28.8 V |
28.8 V |
Product component fusing at power supply input |
Yes |
Yes |
Type of fusing at input for supply voltage |
||
Consumed current maximum |
0.7 A |
2 A |
Active power loss |
||
|
8 W |
15 W |
|
48 W |
48 W |
Permitted ambient conditions |
||
Ambient temperature |
||
|
0 … 60 °C |
-40 … +70 °C |
|
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
Protection class IP |
IP20 |
IP20 |
Design, dimensions and weight |
||
Design |
Modular |
Modular |
Width |
242 mm |
344 mm |
Height |
145 mm |
145 mm |
Depth |
117 mm |
117 mm |
Net weight |
1.9 kg |
3.07 kg |
Type of mounting |
||
|
Yes |
Yes |
|
No |
No |
|
Yes |
Yes |
Type of mounting |
- |
- |
Product properties, functions, componentsgeneral |
||
Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s |
50 |
50 |
Cascading in cases of star structuring |
Any (depending only on signal propagation time) |
Any (depending only on signal propagation time) |
Product functionsmanagement, configuration |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
- |
- |
|
Yes |
Yes |
|
Yes |
Yes |
Protocol is supported |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Identification & maintenance |
||
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsDiagnosis |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsVLAN |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
Number of VLANs maximum |
64 |
64 |
Number of VLANs - dynamic maximum |
64 |
64 |
Protocol is supported GVRP |
Yes |
Yes |
Product functionsDHCP |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsRouting |
||
Product function |
||
|
No |
Yes |
|
No |
Yes |
Protocol is supported |
||
|
No |
Yes |
|
No |
Yes |
|
No |
Yes |
Product functionsRedundancy |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Protocol is supported |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsSecurity |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Protocol is supported SSH |
Yes |
Yes |
Product functionsTime |
||
Product function SICLOCK support |
Yes |
Yes |
Protocol is supported |
||
|
No |
No |
|
Yes |
Yes |
Standards, specifications, approvals |
||
Standard |
||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T4 A, Class 1, Zone 2, Group IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4 A, Class 1, Zone 2, Group IIC, T4 |
|
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
|
UL 60950-1, CSA C22.2 No. 60950-1-03 |
UL 60950-1, CSA C22.2 No. 60950-1-03 |
|
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
|
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
|
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
Verification of suitability |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
|
Yes |
Yes |
|
Yes |
Yes |
Marine classification association |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Order No. |
6GK5 492-2AL00-8AA2 |
6GK5 492-2AM00-8AA2 |
6GK5 492-2AN00-8AA2 |
6GK5 492-2AP00-8AA2 |
6GK5 492-2AQ00-8AA2 |
Product type designation |
MM492-2 |
MM492-2LD |
MM492-2LH |
MM492-2LH+ |
MM492-2ELH |
Transmission rate |
|||||
Transfer rate 1 |
1 000 Mbit/s |
1 000 Mbit/s |
1 000 Mbit/s |
1 000 Mbit/s |
1 000 Mbit/s |
Transfer rate 2 |
- |
- |
- |
- |
- |
Transfer rate 3 |
- |
- |
- |
- |
- |
Interfaces |
|||||
Number of electrical/optical connections for network components or terminal equipment maximum |
2 |
2 |
2 |
2 |
2 |
Number of electrical connections |
|||||
|
- |
- |
- |
- |
- |
|
- |
- |
- |
- |
- |
Design of electrical connection |
|||||
|
- |
- |
- |
- |
- |
|
- |
- |
- |
- |
- |
Number of optical interfaces for optical waveguide |
|||||
|
- |
- |
- |
- |
- |
|
2 |
2 |
2 |
2 |
2 |
Design of optical interface for optical waveguide |
|||||
|
- |
- |
- |
- |
- |
|
SC port (multimode up to 0.75 km) |
SC port (singlemode up to 10 km) |
SC port (singlemode up to 40 km) |
SC port (singlemode up to 70 km) |
SC port (singlemode up to 120 km) |
design of the optical connection for fibre optic cable at 10 Gbit/s |
- |
- |
- |
- |
- |
Connectable optical power relative to 1 mW |
|||||
|
-9.5 … -4 dB |
-9.5 … -3 dB |
-6 … +0 dB |
0 … 5 dB |
0 … 5 dB |
|
-3 dB |
-3 dB |
-3 dB |
-3 dB |
-3 dB |
Optical sensitivity relative to 1 mW of the receiver input minimum |
-17 dB |
-21 dB |
-23 dB |
-23 dB |
-30 dB |
Attenuation of fiber-optic cable transmission link minimum necessary |
0 dB |
0 dB |
3 dB |
8 dB |
8 dB |
Range at the optical interface depending on the optical fiber used |
0 … 0.75 km |
0 … 10 km |
8 … 40 km |
30 … 70 km |
37 … 120 km |
Permitted ambient conditions |
|||||
Ambient temperature |
|||||
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
95 % |
95 % |
95 % |
Protection class IP |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
Design, dimensions and weight |
|||||
Design |
Media module |
Media module |
Media module |
Media module |
Media module |
Width |
35 mm |
35 mm |
35 mm |
35 mm |
35 mm |
Height |
145 mm |
145 mm |
145 mm |
145 mm |
145 mm |
Depth |
90 mm |
90 mm |
90 mm |
90 mm |
90 mm |
Net weight |
0.25 kg |
0.25 kg |
0.25 kg |
0.25 kg |
0.25 kg |
Type of mounting Installation in media module slot |
Yes |
Yes |
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
- |
- |
Standards, specifications, approvals |
|||||
Standard |
|||||
|
- |
- |
- |
- |
- |
|
FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
|
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
|
UL 60950-1, CSA C22.2 No. 60950-1-03 |
UL 60950-1, CSA C22.2 No. 60950-1-03 |
UL 60950-1, CSA C22.2 No. 60950-1-03 |
UL 60950-1, CSA C22.2 No. 60950-1-03 |
UL 60950-1, CSA C22.2 No. 60950-1-03 |
|
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
|
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
|
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
Verification of suitability |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
|
Yes |
Yes |
Yes |
Yes |
- |
|
Yes |
Yes |
Yes |
Yes |
- |
|
- |
- |
- |
- |
- |
Marine classification association |
|||||
|
Yes |
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Yes |
Yes |
Order No. |
6GK5 491-2AB00-8AA2 |
6GK5 491-2AC00-8AA2 |
6GK5 491-2AE00-8AA2 |
Product type designation |
MM491-2 |
MM491-2LD |
MM491-2LH+ |
Transmission rate |
|||
Transfer rate 1 |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
Transfer rate 2 |
- |
- |
- |
Transfer rate 3 |
- |
- |
- |
Interfaces |
|||
Number of electrical/optical connections for network components or terminal equipment maximum |
2 |
2 |
2 |
Number of electrical connections |
|||
|
- |
- |
- |
|
- |
- |
- |
Design of electrical connection |
|||
|
- |
- |
- |
|
- |
- |
- |
Number of optical interfaces for optical waveguide |
|||
|
2 |
2 |
2 |
|
- |
- |
- |
Design of optical interface for optical waveguide |
|||
|
BFOC sockets (multimode up to 5 km) |
BFOC port (singlemode up to 26 km) |
SC port (singlemode up to 70 km) |
Connectable optical power relative to 1 mW |
|||
|
-19 … -14 dB |
-15 … -8 dB |
-5 … +0 dB |
|
-3 dB |
-3 dB |
-3 dB |
|
- |
- |
- |
design of the optical connection for fibre optic cable at 10 Gbit/s |
- |
- |
- |
Optical sensitivity relative to 1 mW of the receiver input minimum |
-32 dB |
-34 dB |
-34 dB |
Attenuation of fiber-optic cable transmission link minimum necessary |
0 dB |
0 dB |
3 dB |
Range at the optical interface depending on the optical fiber used |
0 … 5 km |
0 … 26 km |
12 … 70 km |
Permitted ambient conditions |
|||
Ambient temperature |
|||
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
95 % |
Protection class IP |
IP20 |
IP20 |
IP20 |
Design, dimensions and weight |
|||
Design |
Media module |
Media module |
Media module |
Width |
35 mm |
35 mm |
35 mm |
Height |
145 mm |
145 mm |
145 mm |
Depth |
90 mm |
90 mm |
90 mm |
Net weight |
0.26 kg |
0.26 kg |
0.26 kg |
Type of mounting Installation in media module slot |
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
Standards, specifications, approvals |
|||
Standard |
|||
|
- |
- |
- |
|
FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
|
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
|
UL 60950-1, CSA C22.2 No. 60950-1-03 |
UL 60950-1, CSA C22.2 No. 60950-1-03 |
UL 60950-1, CSA C22.2 No. 60950-1-03 |
|
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
|
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
|
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
Verification of suitability |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
- |
- |
- |
Marine classification association |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Order No. |
6GK5 495-8BA00-8AA2 |
6GK5 496-4MA00-8AA2 |
Product type designation |
EM495-8 |
EM496-4 |
Transmission rate |
||
Transfer rate 1 |
10 Mbit/s |
100 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
- |
Transfer rate 3 |
- |
- |
Interfaces |
||
Number of electrical/optical connections for network components or terminal equipment maximum |
8 |
8 |
Number of electrical connections |
||
|
8 |
- |
|
- |
4 |
Design of electrical connection |
||
|
RJ45 port |
- |
Number of optical interfaces for optical waveguide |
||
|
- |
- |
|
- |
- |
Design of optical interface for optical waveguide |
||
|
- |
Dependent on selected media modules |
|
- |
Dependent on selected media modules |
Permitted ambient conditions |
||
Ambient temperature |
||
|
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
Protection class IP |
IP20 |
IP20 |
Design, dimensions and weight |
||
Design |
Extender module |
Extender module |
Width |
112.4 mm |
112.4 mm |
Height |
86 mm |
154 mm |
Depth |
145 mm |
145 mm |
Net weight |
0.56 kg |
0.98 kg |
Type of mounting |
||
|
- |
- |
|
- |
- |
|
- |
- |
Type of mounting |
- |
- |
Standards, specifications, approvals |
||
Standard |
||
|
- |
- |
|
FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 |
|
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
|
UL 60950-1, CSA C22.2 No. 60950-1-03 |
UL 60950-1, CSA C22.2 No. 60950-1-03 |
|
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
|
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
|
EN 61000-6-2:2001 |
EN 61000-6-2:2001 |
Verification of suitability |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
|
Yes |
Yes |
|
Yes |
Yes |
Marine classification association |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |