Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Order No. | 6GK5 788-1AA60-2AA0 | 6GK5 788-2AA60-2AA0 | 6GK5 788-1AA60-6AA0 | 6GK5 788-2AA60-6AA0 |
6GK5 788-1AA60-2AB01) | 6GK5 788-2AA60-2AB01) | 6GK5 788-1AA60-6AB01) | 6GK5 788-2AA60-6AB01) | |
Product type designation | SCALANCE W788-1PRO | SCALANCE W788-2PRO | SCALANCE W788-1RR | SCALANCE W788-2RR |
Transmission rate | ||||
Transmission rate | ||||
| 54 Mbit/s | 54 Mbit/s | 54 Mbit/s | 54 Mbit/s |
| 10 … 100 Mbit/s | 10 … 100 Mbit/s | 10 … 100 Mbit/s | 10 … 100 Mbit/s |
| Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces | ||||
Number of electrical connections | ||||
| 1 | 1 | 1 | 1 |
| 1 | 1 | 1 | 1 |
| 1 | 1 | 1 | 1 |
Design of electrical connection | ||||
| Hybrid socket, RJ45 integrated | Hybrid socket, RJ45 integrated | Hybrid socket, RJ45 integrated | Hybrid socket, RJ45 integrated |
| M12 interface (4-pole, A-coded), hybrid socket, PoE | M12 interface (4-pole, A-coded), hybrid socket, PoE | M12 interface (4-pole, A-coded), hybrid socket, PoE | M12 interface (4-pole, A-coded), hybrid socket, PoE |
design of the removable storage C-PLUG | Yes | Yes | Yes | Yes |
Interfaceswireless | ||||
Number of radio cards permanently installed | 1 | 2 | 1 | 2 |
Number of electrical connections for external antenna(s) | 2 | 4 | 2 | 4 |
Design of the electrical connection for external antenna(s) | R-SMA female (socket) | R-SMA female (socket) | R-SMA female (socket) | R-SMA female (socket) |
Supply voltage, current consumption, power loss | ||||
Type of voltage of supply voltage | DC | DC | DC | DC |
Supply voltage | ||||
| 24 V | 24 V | 24 V | 24 V |
| 48 V | 48 V | 48 V | 48 V |
| 24 V | 24 V | 24 V | 24 V |
| 48 V | 48 V | 48 V | 48 V |
| 48 V | 48 V | 48 V | 48 V |
Current consumed | ||||
| 0.25 A | 0.295 A | 0.25 A | 0.295 A |
| 0.125 A | 0.15 A | 0.125 A | 0.15 A |
| 0.125 A | 0.15 A | 0.125 A | 0.15 A |
Effective power loss | ||||
| 7 W | 7 W | 7 W | 9 W |
| 7 W | 7 W | 7 W | 9 W |
| 7 W | 7 W | 7 W | 9 W |
Permitted ambient conditions | ||||
Ambient temperature | ||||
| -20 … +60 °C | -20 … +60 °C | -20 … +60 °C | -20 … +60 °C |
| -40 … +70 °C | -40 … +70 °C | -40 … +70 °C | -40 … +70 °C |
| -40 … +70 °C | -40 … +70 °C | -40 … +70 °C | -40 … +70 °C |
Relative humidity at 25 °C without condensation during operating maximum | 100 % | 100 % | 100 % | 100 % |
Protection class IP | IP65 | IP65 | IP65 | IP65 |
Ambient condition for (standard) operation mode | When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. | When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. | When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. | When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529. |
Design, dimensions and weight | ||||
Width of enclosure without antenna | 125 mm | 125 mm | 125 mm | 125 mm |
Height of enclosure without antenna | 88 mm | 88 mm | 88 mm | 88 mm |
Depth of enclosure without antenna | 108 mm | 108 mm | 108 mm | 108 mm |
Net weight | 1.05 kg | 1.05 kg | 1.05 kg | 1.05 kg |
Type of mounting | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Wireless frequencies | ||||
Radio frequency | ||||
| 2.41 … 2.48 GHz | 2.41 … 2.48 GHz | 2.41 … 2.48 GHz | 2.41 … 2.48 GHz |
| 4.9 … 5.8 GHz | 4.9 … 5.8 GHz | 4.9 … 5.8 GHz | 4.9 … 5.8 GHz |
Product properties, functions, componentsgeneral | ||||
Number of SSIDs | 8 | 16 | 8 | 16 |
Product function | ||||
| No | No | Yes | Yes |
| No | No | Yes | Yes |
| No | No | Yes | Yes |
| No | No | No | Yes |
Number of iPCF-capable radio modules | 0 | 0 | 1 | 1 |
Product functionsmanagement, configuration | ||||
Number of manageable IP addresses in client | 8 | 8 | 8 | 8 |
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Protocol is supported | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Identification & maintenance | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Product functionsDiagnosis | ||||
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Product functionsVLAN | ||||
Product function function VLAN with IWLAN | Yes | Yes | Yes | Yes |
Product functionsDHCP | ||||
Product function DHCP client | Yes | Yes | Yes | Yes |
Product functionsRedundancy | ||||
Protocol is supported STP/RSTP | Yes | Yes | Yes | Yes |
Product functionsSecurity | ||||
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Protocol is supported SSH | Yes | Yes | Yes | Yes |
Product functionsTime | ||||
Protocol is supported SNTP | Yes | Yes | Yes | Yes |
Standards, specifications, approvals | ||||
Standard | ||||
| FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
| EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
| UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 |
| ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 | ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 | ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 | ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 |
Certificate of suitability | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Standard for wireless communication | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
Wireless approval | ||||
Marine classification association | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Marine classification association / Polski Rejestr Statkow (PRS) | Yes | Yes | Yes | Yes |
Accessories | ||||
Accessories | 2 antennas, hybrid connector included in scope of delivery | 2 antennas, hybrid connector included in scope of delivery | 2 antennas, hybrid connector included in scope of delivery | 2 antennas, hybrid connector included in scope of delivery |
1) Wireless approval in the USA
Order No. | 6GK5 786-1BA60-2AA0 | 6GK5 786-1AA60-2AA0 | 6GK5 786-1BB60-2AA0 | 6GK5 786-1AB60-2AA0 |
6GK5 786-1BA60-2AB01) | 6GK5 786-1AA60-2AB01) | 6GK5 786-1BB60-2AB01) | 6GK5 786-1AB60-2AB01) | |
Product type designation | SCALANCE W786-1PRO | SCALANCE W786-1PRO | SCALANCE W786-1PRO | SCALANCE W786-1PRO |
Transmission rate | ||||
Transmission rate | ||||
| 54 Mbit/s | 54 Mbit/s | 54 Mbit/s | 54 Mbit/s |
| 10 … 100 Mbit/s | 10 … 100 Mbit/s | 10 … 100 Mbit/s | 10 … 100 Mbit/s |
| Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces | ||||
Number of electrical connections | ||||
| 1 | 1 | - | - |
| 1 | 1 | 1 | 1 |
| 1 | 1 | 1 | 1 |
Design of electrical connection | ||||
| RJ45 socket | RJ45 socket | - | - |
| 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) | 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) | 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) | 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
Number of optical interfaces for optical waveguide at 100 Mbit/s | - | - | 1 | 1 |
Design of optical interface for optical waveguide at 100 Mbit/s | - | - | Duplex multimode FOC (ST) | Duplex multimode FOC (ST) |
design of the removable storage C-PLUG | Yes | Yes | Yes | Yes |
Interfaceswireless | ||||
Number of radio cards permanently installed | 1 | 1 | 1 | 1 |
Number of internal antennas | 2 | - | 2 | - |
Number of electrical connections for external antenna(s) | - | 2 | - | 2 |
Design of the electrical connection for external antenna(s) | - | R-SMA female (socket) | - | R-SMA female (socket) |
Supply voltage, current consumption, power loss | ||||
Type of voltage of supply voltage | DC | DC | DC | DC |
Supply voltage | ||||
| 48 V | 48 V | 48 V | 48 V |
| - | - | - | - |
| 48 V | 48 V | 48 V | 48 V |
| ||||
| 100 … 240 V | 100 … 240 V | 100 … 240 V | 100 … 240 V |
| 12 … 24 V | 12 … 24 V | 12 … 24 V | 12 … 24 V |
Current consumed | ||||
| 0.28 A | 0.28 A | 0.34 A | 0.34 A |
| 0.14 A | 0.14 A | 0.17 A | 0.17 A |
| 0.03 A | 0.03 A | 0.04 A | 0.04 A |
| 0.14 A | 0.14 A | 0.34 A | 0.34 A |
Effective power loss | ||||
| 6.5 W | 6.5 W | 8 W | 8 W |
| 6.5 W | 6.5 W | 8 W | 8 W |
| 6.5 W | 6.5 W | 8 W | 8 W |
| 6.5 W | 6.5 W | 8 W | 8 W |
Permitted ambient conditions | ||||
Ambient temperature | ||||
| -40 … +70 °C | -40 … +70 °C | -40 … +70 °C | -40 … +70 °C |
| -40 … +85 °C | -40 … +85 °C | -40 … +85 °C | -40 … +85 °C |
| -40 … +85 °C | -40 … +85 °C | -40 … +85 °C | -40 … +85 °C |
Relative humidity at 25 °C without condensation during operating maximum | 100 % | 100 % | 100 % | 100 % |
Protection class IP | IP65 | IP65 | IP65 | IP65 |
Ambient condition for (standard) operation mode | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
Design, dimensions and weight | ||||
Width of enclosure without antenna | 251 mm | 251 mm | 251 mm | 251 mm |
Height of enclosure without antenna | 251 mm | 251 mm | 251 mm | 251 mm |
Depth of enclosure without antenna | 72 mm | 72 mm | 72 mm | 72 mm |
Net weight | 2.24 kg | 2.24 kg | 2.24 kg | 2.24 kg |
Type of mounting | ||||
| - | - | - | - |
| Yes | Yes | Yes | Yes |
Type of mounting | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
Wireless frequencies | ||||
Radio frequency | ||||
| 2.41 … 2.48 GHz | 2.41 … 2.48 GHz | 2.41 … 2.48 GHz | 2.41 … 2.48 GHz |
| 4.9 … 5.8 GHz | 4.9 … 5.8 GHz | 4.9 … 5.8 GHz | 4.9 … 5.8 GHz |
Product properties, functions, componentsgeneral | ||||
Number of SSIDs | 8 | 8 | 8 | 8 |
Product function | ||||
| No | No | No | No |
| No | No | No | No |
| No | No | No | No |
| No | No | No | No |
Number of iPCF-capable radio modules | 0 | 0 | 0 | 0 |
Product functionsmanagement, configuration | ||||
Number of manageable IP addresses in client | 8 | 8 | 8 | 8 |
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Protocol is supported | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Identification & maintenance | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Product functionsDiagnosis | ||||
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Product functionsVLAN | ||||
Product function function VLAN with IWLAN | Yes | Yes | Yes | Yes |
Product functionsDHCP | ||||
Product function DHCP client | Yes | Yes | Yes | Yes |
Product functionsRedundancy | ||||
Protocol is supported STP/RSTP | Yes | Yes | Yes | Yes |
Product functionsSecurity | ||||
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Protocol is supported SSH | Yes | Yes | Yes | Yes |
Product functionsTime | ||||
Protocol is supported SNTP | Yes | Yes | Yes | Yes |
Standards, specifications, approvals | ||||
Standard | ||||
| FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
| EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
| UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 |
| UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 | UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 | UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 | UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
Certificate of suitability | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Standard for wireless communication | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
Wireless approval | You can find the current list of countries at: www.siemens.com/simatic-net/ik-info | |||
Marine classification association | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Marine classification association / Polski Rejestr Statkow (PRS) | No | No | No | No |
Accessories | ||||
Accessories | 48 V DC screw terminal included in scope of delivery | 48 V DC screw terminal included in scope of delivery | 48 V DC screw terminal included in scope of delivery | 48 V DC screw terminal included in scope of delivery |
1) Wireless approval in the USA
Order No. | 6GK5 786-2BA60-2AA0 | 6GK5 786-2AA60-2AA0 | 6GK5 786-2BB60-2AA0 | 6GK5 786-2AB60-2AA0 |
6GK5 786-2BA60-2AB01) | 6GK5 786-2AA60-2AB01) | 6GK5 786-2BB60-2AB01) | 6GK5 786-2AB60-2AB01) | |
Product type designation | SCALANCE W786-2PRO | SCALANCE W786-2PRO | SCALANCE W786-2PRO | SCALANCE W786-2PRO |
Transmission rate | ||||
Transmission rate | ||||
| 54 Mbit/s | 54 Mbit/s | 54 Mbit/s | 54 Mbit/s |
| 10 … 100 Mbit/s | 10 … 100 Mbit/s | 10 … 100 Mbit/s | 10 … 100 Mbit/s |
| Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces | ||||
Number of electrical connections | ||||
| 1 | 1 | - | - |
| 1 | 1 | 1 | 1 |
| 1 | 1 | 1 | 1 |
Design of electrical connection | ||||
| RJ45 socket | RJ45 socket | - | - |
| 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) | 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) | 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) | 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
Number of optical interfaces for optical waveguide at 100 Mbit/s | - | - | 1 | 1 |
Design of optical interface for optical waveguide at 100 Mbit/s | - | - | Duplex multimode FOC (ST) | Duplex multimode FOC (ST) |
design of the removable storage C-PLUG | Yes | Yes | Yes | Yes |
Interfaceswireless | ||||
Number of radio cards permanently installed | 2 | 2 | 2 | 2 |
Number of internal antennas | 4 | - | 4 | - |
Number of electrical connections for external antenna(s) | - | 4 | - | 4 |
Design of the electrical connection for external antenna(s) | - | R-SMA female (socket) | - | R-SMA female (socket) |
Supply voltage, current consumption, power loss | ||||
Type of voltage of supply voltage | DC | DC | DC | DC |
Supply voltage | ||||
| 48 V | 48 V | 48 V | 48 V |
| - | - | - | - |
| 48 V | 48 V | 48 V | 48 V |
| ||||
| 100 … 240 V | 100 … 240 V | 100 … 240 V | 100 … 240 V |
| 12 … 24 V | 12 … 24 V | 12 … 24 V | 12 … 24 V |
Current consumed | ||||
| 0.34 A | 0.34 A | 0.4 A | 0.4 A |
| 0.17 A | 0.17 A | 0.2 A | 0.2 A |
| 0.04 A | 0.04 A | 0.05 A | 0.05 A |
| 0.34 A | 0.34 A | 0.2 A | 0.2 A |
Effective power loss | ||||
| 8 W | 8 W | 9.5 W | 9.5 W |
| 8 W | 8 W | 9.5 W | 9.5 W |
| 8 W | 8 W | 9.5 W | 9.5 W |
| 8 W | 8 W | 9.5 W | 9.5 W |
Permitted ambient conditions | ||||
Ambient temperature | ||||
| -40 … +70 °C | -40 … +70 °C | -40 … +70 °C | -40 … +70 °C |
| -40 … +85 °C | -40 … +85 °C | -40 … +85 °C | -40 … +85 °C |
| -40 … +85 °C | -40 … +85 °C | -40 … +85 °C | -40 … +85 °C |
Relative humidity at 25 °C without condensation during operating maximum | 100 % | 100 % | 100 % | 100 % |
Protection class IP | IP65 | IP65 | IP65 | IP65 |
Ambient condition for (standard) operation mode | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
Design, dimensions and weight | ||||
Width of enclosure without antenna | 251 mm | 251 mm | 251 mm | 251 mm |
Height of enclosure without antenna | 251 mm | 251 mm | 251 mm | 251 mm |
Depth of enclosure without antenna | 72 mm | 72 mm | 72 mm | 72 mm |
Net weight | 2.24 kg | 2.24 kg | 2.24 kg | 2.24 kg |
Type of mounting | ||||
| - | - | - | - |
| Yes | Yes | Yes | Yes |
Type of mounting | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
Wireless frequencies | ||||
Radio frequency | ||||
| 2.41 … 2.48 GHz | 2.41 … 2.48 GHz | 2.41 … 2.48 GHz | 2.41 … 2.48 GHz |
| 4.9 … 5.8 GHz | 4.9 … 5.8 GHz | 4.9 … 5.8 GHz | 4.9 … 5.8 GHz |
Product properties, functions, componentsgeneral | ||||
Number of SSIDs | 16 | 16 | 16 | 16 |
Product function | ||||
| No | No | No | No |
| No | No | No | No |
| No | No | No | No |
| No | No | No | No |
Number of iPCF-capable radio modules | 0 | 0 | 0 | 0 |
Product functionsmanagement, configuration | ||||
Number of manageable IP addresses in client | 8 | 8 | 8 | 8 |
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Protocol is supported | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Identification & maintenance | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Product functionsDiagnosis | ||||
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Product functionsVLAN | ||||
Product function function VLAN with IWLAN | Yes | Yes | Yes | Yes |
Product functionsDHCP | ||||
Product function DHCP client | Yes | Yes | Yes | Yes |
Product functionsRedundancy | ||||
Protocol is supported STP/RSTP | Yes | Yes | Yes | Yes |
Product functionsSecurity | ||||
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Protocol is supported SSH | Yes | Yes | Yes | Yes |
Product functionsTime | ||||
Protocol is supported SNTP | Yes | Yes | Yes | Yes |
Standards, specifications, approvals | ||||
Standard | ||||
| FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
| EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
| UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 |
| UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 | UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 | UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 | UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
Certificate of suitability | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Standard for wireless communication | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
Wireless approval | ||||
Marine classification association | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) | No | No | No | No |
Accessories | ||||
Accessories | 48 V DC screw terminal included in scope of delivery | 48 V DC screw terminal included in scope of delivery | 48 V DC screw terminal included in scope of delivery | 48 V DC screw terminal included in scope of delivery |
1) Wireless approval in the USA
Order No. | 6GK5 786-3AA60-2AA0 | 6GK5 786-3AB60-2AA0 | 6GK5 786-2BA60-6AA0 | 6GK5 786-2AA60-6AA0 |
6GK5 786-3AA60-2AB01) | 6GK5 786-3AB60-2AB01) | 6GK5 786-2BA60-6AB01) | 6GK5 786-2AA60-6AB01) | |
Product type designation | SCALANCE W786-3PRO | SCALANCE W786-3PRO | SCALANCE W786-2RR | SCALANCE W786-2RR |
Transmission rate | ||||
Transmission rate | ||||
| 54 Mbit/s | 54 Mbit/s | 54 Mbit/s | 54 Mbit/s |
| 10 … 100 Mbit/s | 10 … 100 Mbit/s | 10 … 100 Mbit/s | 10 … 100 Mbit/s |
| Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces | ||||
Number of electrical connections | ||||
| 1 | - | 1 | 1 |
| 1 | 1 | 1 | 1 |
| 1 | 1 | 1 | 1 |
Design of electrical connection | ||||
| RJ45 socket | - | RJ45 socket | RJ45 socket |
| 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) | 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) | 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) | 2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC) |
Number of optical interfaces for optical waveguide at 100 Mbit/s | - | 1 | - | - |
Design of optical interface for optical waveguide at 100 Mbit/s | - | Duplex multimode FOC (ST) | - | - |
design of the removable storage C-PLUG | Yes | Yes | Yes | Yes |
Interfaceswireless | ||||
Number of radio cards permanently installed | 3 | 3 | 2 | 2 |
Number of internal antennas | - | - | 4 | - |
Number of electrical connections for external antenna(s) | 6 | 6 | - | 4 |
Design of the electrical connection for external antenna(s) | R-SMA female (socket) | R-SMA female (socket) | - | R-SMA female (socket) |
Supply voltage, current consumption, power loss | ||||
Type of voltage of supply voltage | DC | DC | DC | DC |
Supply voltage | ||||
| 48 V | 48 V | 48 V | 48 V |
| - | - | - | - |
| 48 V | 48 V | 48 V | 48 V |
| ||||
| 100 … 240 V | 100 … 240 V | 100 … 240 V | 100 … 240 V |
| 12 … 24 V | 12 … 24 V | 12 … 24 V | 12 … 24 V |
Current consumed | ||||
| 0.4 A | 0.46 A | 0.34 A | 0.34 A |
| 0.2 A | 0.23 A | 0.17 A | 0.17 A |
| 0.05 A | 0.05 A | 0.04 A | 0.04 A |
| 0.2 A | 0.23 A | 0.34 A | 0.34 A |
Effective power loss | ||||
| 9.5 W | 11 W | 8 W | 8 W |
| 9.5 W | 11 W | 8 W | 8 W |
| 9.5 W | 11 W | 8 W | 8 W |
| 9.5 W | 11 W | 8 W | 8 W |
Permitted ambient conditions | ||||
Ambient temperature | ||||
| -40 … +70 °C | -40 … +70 °C | -40 … +70 °C | -40 … +70 °C |
| -40 … +85 °C | -40 … +85 °C | -40 … +85 °C | -40 … +85 °C |
| -40 … +85 °C | -40 … +85 °C | -40 … +85 °C | -40 … +85 °C |
Relative humidity at 25 °C without condensation during operating maximum | 100 % | 100 % | 100 % | 100 % |
Protection class IP | IP65 | IP65 | IP65 | IP65 |
Ambient condition for (standard) operation mode | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible | When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible |
Design, dimensions and weight | ||||
Width of enclosure without antenna | 251 mm | 251 mm | 251 mm | 251 mm |
Height of enclosure without antenna | 251 mm | 251 mm | 251 mm | 251 mm |
Depth of enclosure without antenna | 72 mm | 72 mm | 72 mm | 72 mm |
Net weight | 2.24 kg | 2.24 kg | 2.24 kg | 2.24 kg |
Type of mounting | ||||
| - | - | - | - |
| Yes | Yes | Yes | Yes |
Type of mounting | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required | For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required |
Wireless frequencies | ||||
Radio frequency | ||||
| 2.41 … 2.48 GHz | 2.41 … 2.48 GHz | 2.41 … 2.48 GHz | 2.41 … 2.48 GHz |
| 4.9 … 5.8 GHz | 4.9 … 5.8 GHz | 4.9 … 5.8 GHz | 4.9 … 5.8 GHz |
Product properties, functions, componentsgeneral | ||||
Number of SSIDs | 24 | 24 | 16 | 16 |
Product function | ||||
| No | No | Yes | Yes |
| No | No | Yes | Yes |
| No | No | Yes | Yes |
| No | No | Yes | Yes |
Number of iPCF-capable radio modules | 0 | 0 | 1 | 1 |
Product functionsmanagement, configuration | ||||
Number of manageable IP addresses in client | 8 | 8 | 8 | 8 |
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Protocol is supported | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Identification & maintenance | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Product functionsDiagnosis | ||||
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Product functionsVLAN | ||||
Product function function VLAN with IWLAN | Yes | Yes | Yes | Yes |
Product functionsDHCP | ||||
Product function DHCP client | Yes | Yes | Yes | Yes |
Product functionsRedundancy | ||||
Protocol is supported STP/RSTP | Yes | Yes | Yes | Yes |
Product functionsSecurity | ||||
Product function | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Protocol is supported SSH | Yes | Yes | Yes | Yes |
Product functionsTime | ||||
Protocol is supported SNTP | Yes | Yes | Yes | Yes |
Standards, specifications, approvals | ||||
Standard | ||||
| FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
| EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
| UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 |
| UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 | UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 | UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 | UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 |
Certificate of suitability | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Standard for wireless communication | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
Wireless approval | ||||
Marine classification association | ||||
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| No | No | No | No |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) | No | No | No | No |
Accessories | ||||
Accessories | 48 V DC screw terminal included in scope of delivery | 48 V DC screw terminal included in scope of delivery | 48 V DC screw terminal included in scope of delivery | 48 V DC screw terminal included in scope of delivery |
1) Wireless approval in the USA
Order No. | 6GK5 784-1AA30-2AA0 | 6GK5 784-1AA30-6AA0 |
6GK5 784-1AA30-2AB01) | 6GK5 784-1AA30-6AB01) | |
Product type designation | SCALANCE W784-1 | SCALANCE W784-1RR |
Transmission rate | ||
Transmission rate | ||
| 54 Mbit/s | 54 Mbit/s |
| 10 … 100 Mbit/s | 10 … 100 Mbit/s |
| Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) | Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode) |
Interfaces | ||
Number of electrical connections | ||
| 1 | 1 |
| 1 | 1 |
| 1 | 1 |
Design of electrical connection | ||
| RJ45 socket | RJ45 socket |
| 4-pole screw terminal, PoE | 4-pole screw terminal, PoE |
design of the removable storage C-PLUG | Yes | Yes |
Interfaceswireless | ||
Number of radio cards permanently installed | 1 | 1 |
Number of electrical connections for external antenna(s) | 2 | 2 |
Design of the electrical connection for external antenna(s) | R-SMA female (socket) | R-SMA female (socket) |
Supply voltage, current consumption, power loss | ||
Type of voltage of supply voltage | DC | DC |
Supply voltage | ||
| 24 V | 24 V |
| 48 V | 48 V |
| 48 V | 48 V |
Current consumed | ||
| 0.23 A | 0.23 A |
| 0.12 A | 0.12 A |
| 0.12 A | 0.12 A |
Effective power loss | ||
| 6 W | 6 W |
| 6 W | 6 W |
| 6 W | 6 W |
Permitted ambient conditions | ||
Ambient temperature | ||
| -20 … +60 °C | -20 … +60 °C |
| -40 … +70 °C | -40 … +70 °C |
| -40 … +70 °C | -40 … +70 °C |
Relative humidity at 25 °C without condensation during operating maximum | 90 % | 90 % |
Protection class IP | IP30 | IP30 |
Ambient condition for (standard) operation mode | - | - |
Design, dimensions and weight | ||
Width of enclosure without antenna | 100 mm | 100 mm |
Height of enclosure without antenna | 205 mm | 205 mm |
Depth of enclosure without antenna | 20 mm | 20 mm |
Net weight | 0.29 kg | 0.29 kg |
Type of mounting | ||
| - | - |
| Yes | Yes |
Type of mounting | For mounting on 35 mm DIN and S7-300 mounting rail, an additional adapter plate is required | For mounting on 35 mm DIN and S7-300 mounting rail, an additional adapter plate is required |
Wireless frequencies | ||
Radio frequency | ||
| 2.41 … 2.48 GHz | 2.41 … 2.48 GHz |
| 4.9 … 5.8 GHz | 4.9 … 5.8 GHz |
Product properties, functions, componentsgeneral | ||
Number of SSIDs | 8 | 8 |
Product function | ||
| No | Yes |
| No | Yes |
| No | Yes |
| No | No |
Number of iPCF-capable radio modules | 0 | 1 |
Product functionsmanagement, configuration | ||
Number of manageable IP addresses in client | 8 | 8 |
Product function | ||
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| No | No |
| No | No |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Protocol is supported | ||
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Identification & maintenance | ||
| Yes | Yes |
| Yes | Yes |
Product functionsDiagnosis | ||
Product function | ||
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Product functionsVLAN | ||
Product function function VLAN with IWLAN | Yes | Yes |
Product functionsDHCP | ||
Product function DHCP client | Yes | Yes |
Product functionsRedundancy | ||
Protocol is supported STP/RSTP | Yes | Yes |
Product functionsSecurity | ||
Product function | ||
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Protocol is supported SSH | Yes | Yes |
Product functionsTime | ||
Protocol is supported SNTP | Yes | Yes |
Standards, specifications, approvals | ||
Standard | ||
| FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 | FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4 |
| EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X (only approved in combination with an enclosure with degree of protection of at least IP 54) | EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X (only approved in combination with an enclosure with degree of protection of at least IP 54) |
| UL 60950-1 CSA C22.2 No. 60950-1 | UL 60950-1 CSA C22.2 No. 60950-1 |
| ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 (only approved in combination with an enclosure with degree of protection of at least IP 54) | ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 (only approved in combination with an enclosure with degree of protection of at least IP 54) |
Certificate of suitability | ||
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| No | No |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Standard for wireless communication | ||
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| No | No |
Wireless approval | ||
Marine classification association | ||
| Yes | Yes |
| Yes | Yes |
| No | No |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) | No | No |
Accessories | ||
Accessories | 24 V DC screw terminal included in scope of delivery | 24 V DC screw terminal included in scope of delivery |
1) Wireless approval in the USA