Differentiation of cases: Ex zones/danger through flammable sample gas
|
Gas type |
Sample gas non-flammable below the lower explosive limit (LEL) |
Sample gas is flammable and/or is rarely, and then only briefly, above the LEL |
Sample gas is flammable and/or is occasionally above the LEL |
|
---|---|---|---|---|---|
Category ATEX II 1G (zone 0) |
Individual acceptance test (on request) |
Individual acceptance test (on request) |
Individual acceptance test (on request) |
||
Category ATEX II 2G (zone 1) Operating mode "Leakage compensation" |
Analyzer |
|
|
|
|
Gas path |
|
|
|
||
Flame arrester |
— |
— |
Flame arrester in sample gas inlet and outlet |
||
Monitoring |
|
|
|
||
Pressure switch |
— |
|
|
||
Category ATEX II 2G Operating mode "Continuous purging" |
Analyzer |
|
|
|
|
Gas path |
|
|
|
||
Flame arrester |
— |
— |
Flame arrester in sample gas inlet and outlet |
||
Monitoring |
|
|
|
||
Pressure switch |
— |
— |
— |
||
Category ATEX II 3G (zone 2) |
Analyzer |
|
|
|
|
Gas path |
|
|
|
||
Flame arrester |
— |
— |
|
||
Monitoring |
— |
|
|
||
Non-hazardous zone |
Analyzer |
|
|
|
|
Gas path |
|
|
|
||
Flame arrester |
— |
— |
|
||
Monitoring |
— |
— |
|
Ex configurations – principle selection criteria
Signal line routing |
|||
---|---|---|---|
Within zone 1 |
From zone 1 to zone 2 |
From zone 1 to non-hazardous zone |
|
Ex i isolation amplifier |
Required |
Conditional use (when energy feedback cannot be excluded) |
Conditional use (when energy feedback cannot be excluded) |
Isolating relay |
Required |
Conditional use (when energy feedback cannot be excluded) |
Conditional use (when energy feedback cannot be excluded) |
Additional units, selection criteria (ATEX 2G)
Use of OXYMAT 6 in hazardous area and/or for measurement of flammable gases
Certification (short codes) |
Additional unit |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Order No. |
Gas |
Dust |
Gas warning unit |
Purging unit |
Flame arrestor |
Pressure switch |
Ex i isolation amplifier |
Ex i isolating relay |
|||
Category |
Operating mode |
Ex zone |
Ex zone |
Non-heated |
Heated |
7MB8000- |
7MB8000- |
7MB8000- |
7MB8000- |
7MB8000- |
|
ATEX II 2G |
Leakage compensation |
7MB2011-***0*-2*** |
X |
— |
E31 |
E31 + E38 |
2BB |
6BA/6BB1) |
5AA1) |
3AA1) |
4AB1) |
7MB2011-***0*-3*** |
X |
— |
E31 |
E31 + E39 |
2BA |
6BA/6BB1) |
5AA1) |
3AA1) |
4AA1) |
||
Continuous purging |
7MB2011-***0*-6*** |
X |
— |
E32 |
E32 + E38 |
2CB |
6BA/6BB1) |
o |
3AA1) |
4AB1) |
|
7MB2011-***0*-7*** |
X |
— |
E32 |
E32 + E39 |
2CA |
6BA/6BB1) |
o |
3AA1) |
4AA1) |
||
ATEX II 3G |
Flammable gases |
7MB2011-***0*-0*** |
E12 |
— |
E33 |
E33 + E38 |
2CB |
6BA/6BB1) |
o |
o |
o |
7MB2011-***0*-1*** |
E12 |
— |
E33 |
E33 + E39 |
2CA |
6BA/6BB1) |
o |
o |
o |
||
7MB2011-***0*-0*** |
E42 |
— |
— |
2CB |
6BA/6BB1) |
o |
o |
o |
|||
7MB2011-***0*-1*** |
E42 |
— |
— |
2CA |
6BA/6BB1) |
o |
o |
o |
|||
Non-flammable gases |
7MB2011-***0*-0*** |
E11 |
— |
E33 |
E33 + E38 |
o |
o |
o |
o |
o |
|
7MB2011-***0*-1*** |
E11 |
— |
E33 |
E33 + E39 |
o |
o |
o |
o |
o |
||
7MB2011-***0*-0*** |
E41 |
— |
— |
o |
o |
o |
o |
o |
|||
7MB2011-***0*-1*** |
E41 |
— |
— |
o |
o |
o |
o |
o |
|||
Non-hazardous zone |
Non-hazardous gas zone |
7MB2011-***0*-0*** |
E40 |
— |
— |
o |
o |
o |
o |
o |
|
7MB2011-***0*-1*** |
E40 |
— |
— |
o |
o |
o |
o |
o |
|||
7MB2011-***0*-0*** |
— |
— |
E30 |
E30 + E38 |
o |
o |
o |
o |
o |
||
7MB2011-***0*-1*** |
— |
— |
E30 |
E30 + E39 |
o |
o |
o |
o |
o |
||
7MB2021-****0-**** |
X |
— |
E30 |
— |
o |
o |
o |
o |
o |
||
CLASS 1 Div 2 |
Flammable and non-flammable gases |
7MB2011-***0*-0*** |
E20 |
— |
— |
— |
1AA |
6BA/6BB |
o |
o |
o |
7MB2021-*****-****2) |
— Combination not allowed
X Possible combination, no additional data required
o Not required
Ex configurations, possible combinations
1) Conditionally required: see table of Ex configurations, selection criteria
2) Installation in additional enclosure required
Use of ULTRAMAT 6 in hazardous area and/or for measurement of flammable gases
Certification and short codes |
Additional unit |
||||||||
---|---|---|---|---|---|---|---|---|---|
Order No. |
Gas |
Dust |
Purging unit |
Flame arrestor |
Pressure switch |
Ex i isolation amplifier |
Ex i isolating relay |
||
Category |
Operating mode |
7MB2111- |
Ex zone |
Ex zone |
7MB8000- |
7MB8000- |
7MB8000- |
7MB8000- |
7MB8000- |
ATEX II 2G |
Leakage compensation |
*****-2*A* |
X |
— |
2BB |
6BA/6BB1) |
5AA1) |
3AA1) |
4AB1) |
*****-3*A* |
X |
— |
2BA |
6BA/6BB1) |
5AA1) |
3AA1) |
4AA1) |
||
Continuous purging |
*****-6*A* |
X |
— |
2CB |
6BA/6BB1) |
o |
3AA1) |
4AB1) |
|
*****-7*A* |
X |
— |
2CA |
6BA/6BB1) |
o |
3AA1) |
4AA1) |
||
ATEX II 3G |
Flammable gases |
*****-0*A* |
E42 |
2CB |
6BA/6BB1) |
o |
o |
o |
|
*****-1*A* |
E42 |
2CA |
6BA/6BB1) |
o |
o |
o |
|||
*****-0*A* |
E12 |
— |
2CB |
o |
o |
o |
o |
||
*****-1*A* |
E12 |
— |
2CA |
o |
o |
o |
o |
||
Non-flammable gases |
*****-0*A* |
E41 |
o |
o |
o |
o |
o |
||
*****-1*A* |
E41 |
o |
o |
o |
o |
o |
|||
*****-0*A* |
E11 |
— |
o |
o |
o |
o |
o |
||
*****-1*A* |
E11 |
— |
o |
o |
o |
o |
o |
||
Non-hazardous zone |
Non-hazardous gas zone |
*****-0*A* |
X |
E40 |
o |
o |
o |
o |
o |
*****-1*A* |
X |
E40 |
o |
o |
o |
o |
o |
||
CLASS 1 Div 2 |
Flammable and non-flammable gases |
7MB2111-*****-0*A*, 7MB2111-*****-1*A* 7MB212*-*****-****2) |
E20 |
— |
1AA |
6BA/6BB |
o |
o |
o |
— Combination not allowed
X Possible combination, no additional data required
o Not required
1) Conditionally required; see table of Ex configurations, selection criteria.
2) Installation in additional enclosure required
Use of CALOMAT 6 in hazardous area and/or for measurement of flammable gases
Certification |
Additional unit |
||||||||
---|---|---|---|---|---|---|---|---|---|
Order No. |
Gas |
Dust |
Purging unit |
Flame arrester |
Pressure switch |
Ex i isolation amplifier |
Ex i isolating relay |
||
Category |
Operating mode |
7MB8000- |
7MB8000- |
7MB8000- |
7MB8000- |
7MB8000- |
|||
ATEX II 2G |
Leakage compensation |
7MB2511-***0*-0AE* |
X |
— |
2BB |
6BA/6BB1) |
5AA1) |
3AA1) |
4AB1) |
7MB2511-***0*-1AE* |
X |
— |
2BA |
6BA/6BB1) |
5AA1) |
3AA1) |
4AA1) |
||
Continuous purging |
7MB2511-***0*-0AF* |
X |
— |
2CB |
6BA/6BB1) |
o |
3AA1) |
4AB1) |
|
7MB2511-***0*-1AF* |
X |
— |
2CA |
6BA/6BB1) |
o |
3AA1) |
4AA1) |
||
ATEX II 3G |
Flammable gases |
7MB2511-***0*-*AJ* |
X |
X |
2CA/2CB |
6BA/6BB1) |
o |
o |
o |
7MB2511-***0*-*AC* |
X |
— |
2CA/2CB |
6BA/6BB1) |
o |
o |
o |
||
7MB2521-***0*-*AB* |
X |
— |
acc. to Certificate |
6BA/6BB1) |
o |
o |
o |
||
Non-flammable gases |
7MB2511-***0*-*AH* |
X |
X |
o |
o |
o |
o |
o |
|
7MB2511-***0*-*AB* |
X |
— |
o |
o |
o |
o |
o |
||
7MB2521-***0*-*AB* |
X |
— |
o |
o |
o |
o |
o |
||
Non-hazardous zone |
Non-hazardous gas zone |
7MB2511-***0*-*AG* |
— |
X |
o |
o |
o |
o |
o |
CLASS 1 Div 2 |
Flammable and non-flammable gases |
7MB2511-***0*-0AD*, 7MB2511-***0*-1AD* 7MB2521-***D*-**D* 7MB2521-***D*-**B* |
X |
— |
7MB8000-1AA |
6BA/6BB |
o |
o |
o |
X Possible combination, no additional data required
— Combination not allowed
o Not required
Ex configurations, possible combinations
1) Conditionally required; see table of Ex configurations; selection criteria
Use of ULTRAMAT 23 in hazardous area and/or for measurement of flammable gases
Certification and short codes |
Additional unit |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|
Order No. |
Gas |
Dust |
Purging unit |
Gas path |
Flame arrestor |
Pressure switch |
Ex i isolation amplifier |
Ex i isolating relay |
||
Category |
Operating mode |
7MB233*- |
Ex zone |
Ex zone |
7MB8000- |
7MB8000- |
7MB8000- |
7MB8000- |
7MB8000- |
|
ATEX II 3G |
Flammable gases1) |
*****-**** |
X |
— |
2CB |
Metal |
6AA/6AB |
o |
o |
o |
*****-**** |
X |
— |
2CA |
Metal |
6AA/6AB |
o |
o |
o |
||
Non-flammable gases1) |
*****-**** |
X |
— |
o |
Metal2) |
o |
o |
o |
o |
|
*****-**** |
X |
— |
o |
Metal2) |
o |
o |
o |
o |
||
Non-hazardous zone |
Class 1 Div 2 |
*****-**** |
X |
— |
1AA |
o |
o |
o |
o |
o |
*****-**** |
X |
— |
o |
o |
o |
o |
o |
o |
— Combination not allowed
X Possible combination, no additional data required
o Not required / not defined
1) Depends on the gas side, installation in IP54 enclosure necessary, see "FM Approval report" or ATEX approval.
2) Required