General information
Fields of application
  • Measurement for boiler control in incineration plants
  • Emission measurements in incineration plants
  • Measurement in the automotive industry (test benches)
  • Process gas concentrations in chemical plants
  • Trace measurements in pure gas processes
  • Environmental protection
  • TLV (Threshold Limit Value) monitoring at places of work
  • Quality monitoring
Special versions
  • Special applications
    Besides the standard combinations, special applications concerning material in the gas path, material in the sample cells (e.g. Titan, Hastelloy C22) and sample components are also available on request.
  • TUV version/QAL
    TUV-approved versions of the ULTRAMAT/OXYMAT 6 are available for measurement of CO, NO, SO2 and O2 according to 13th and 17th BlmSchV and TA Luft.
    Smallest TUV-approved and permitted measuring ranges:
    • 1-component analyzer
      CO: 0 to 50 mg/m3
      NO: 0 to 100 mg/m3
      SO2: 0 to 75 mg/m3
    • 2-component analyzer (series connection)
      CO: 0 to 75 mg/m3
      NO: 0 to 200 mg/m3

All larger measuring ranges are also approved.

Furthermore, the TUV-approved versions of the ULTRAMAT/OXYMAT 6 comply with the requirements of EN 14956 and QAL 1 according to EN 14181. Conformity of the devices with both standards is TUV-certified.

Determination of the analyzer drift according to EN 14181 (QAL 3) can be carried out manually or also with a PC using the SIPROM GA maintenance and servicing software. In addition, selected manufacturers of emission evaluation computers offer the possibility for downloading the drift data via the analyzer's serial interface and to automatically record and process it in the evaluation computer.

  • Flow-type reference compartment
    • The flow through the reference compartment should be adapted to the sample gas flow
    • The gas supply of the reduced flow-type reference compartment should have an upstream pressure of 3 000 to 5 000 hPa (abs.). Then a restrictor will automatically adjust the flow to approximately 8 hPa






















































Каталог оборудования
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Контрольно-измерительные приборы Анализаторы процесса Непрерывные анализаторы газов Непрерывные анализаторы газов, эктрактивные Введение ULTRAMAT 23 ULTRAMAT 6 ULTRAMAT/OXYMAT 6 General information 19" rack unit Documentation Suggestions for spare parts OXYMAT 6 OXYMAT 61 OXYMAT 64 CALOMAT 6 CALOMAT 62 FIDAMAT 6 Непрерывный газовый анализ, in-situ Промышленные газовые хроматографы Analytical Application Sets General information Технологии взвешивания Датчики зрения Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо