Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/new/cat.php on line 184
Mode of operation |
|
Measuring principle |
Disruption of magnetic field by ferrous target |
Typical application |
Monitors absence or presence of motion in harsh conditions |
Output |
|
Contact |
1 SPDT Form C dry relay contact, rated 5 A at 250 V AC, fail-safe operation |
Time delay |
Start up: 10 to 14 seconds (5 to 7 seconds with 12 ppm jumper installed) |
Zero Speed (selected via a common jumper) |
|
Rated operating conditions |
|
Operating temperature |
-40 to +60 °C (-40 to +140 °F) |
Design |
|
Probe body |
Aluminum |
Process mounting |
2" NPSL |
Connection box |
Aluminum, " NPT conduit entrance, 5 screw terminals plus grounding terminal for electrical connection, max. 12 AWG |
Gasketing |
Neoprene |
Display |
Red LED for verification of pulses |
Enclosure rating |
Type NEMA 4x, 6, IP67 |
Dynamic range |
Minimum 6 or 12 pulses per minute |
Shipping weight |
2 kg (4.4 lb) |
Power supply |
|
Certificates and approvals |
CSAUS/C, CE, C-TICK |