Order No. |
6XV1 830-5FH10 |
6XV1 830-5EH10 |
Product type designation |
PROFIBUS FC Process Cable GP |
PROFIBUS FC Process Cable GP |
Product description |
Bus cable (2-core), sold by the meter, in bulk |
Bus cable (2-core), sold by the meter, in bulk |
Suitability for application |
Use for fieldbus systems in accordance with IEC 61158-2 (e.g. PROFIBUS PA), suitable for non-hazardous applications |
Use for fieldbus systems in accordance with IEC 61158-2 (e.g. PROFIBUS PA), suitable for hazardous applications |
Cable designation |
02YSY (ST) CY 1x2x1.0/2.55-100 SW OE FR |
02YSY (ST) CY 1x2x1.0/2.55-100 BL OE FR |
Cable length |
- |
- |
Electrical specifications |
||
Maximum attenuation factor per length at 38.4 kHz |
3 dB/km |
3 dB/km |
Characteristic impedance |
||
|
100 |
100 |
|
100 |
100 |
Relative symmetrical tolerance of characteristic impedance at 31.25 kHz |
20 % |
20 % |
Max. loop resistance per length |
44 /km |
44 /km |
Max. shield resistance per length |
6.5 /km |
6.5 /km |
Capacitance per length at 1 kHz |
92 pF/m |
92 pF/m |
Inductance per length |
0.65 µH/m |
0.65 µH/m |
Operating voltage, rms value |
100 V |
100 V |
Mechanical data |
||
Number of electrical cores |
2 |
2 |
Design of shield |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Design of electrical connection FastConnect |
Yes |
Yes |
Outer diameter |
||
|
1.05 mm |
1.05 mm |
|
2.55 mm |
2.55 mm |
|
5.4 mm |
5.4 mm |
|
8 mm |
8 mm |
Symmetrical tolerance of outer diameter of cable sheath |
0.4 mm |
0.4 mm |
Outer diameter of cable sheath - Note |
- |
- |
Material |
||
|
PE |
PE |
|
PVC |
PVC |
|
PVC |
PVC |
|
- |
- |
Color |
||
|
Red / green |
Red / green |
|
Black |
Blue |
Bending radius |
||
|
40 mm |
40 mm |
|
80 mm |
80 mm |
|
- |
- |
Number of bending cycles |
- |
- |
|
- |
- |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
- |
Maximum tensile load |
150 N |
150 N |
Weight per length |
103 kg/km |
103 kg/km |
Permitted ambient conditions |
||
Ambient temperature |
||
|
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
|
-20 … +80 °C |
-20 … +80 °C |
Ambient conditions for operation |
Transmission rate of the cable: 31.25 kbit/s |
Transmission rate of the cable: 31.25 kbit/s |
IP degree of protection |
- |
- |
Behavior in fire |
Flame-retardant in accordance with IEC 60332-3-24 (Category C) |
Flame-retardant in accordance with IEC 60332-3-24 (Category C) |
Chemical resistance |
||
|
Limited resistance |
Limited resistance |
|
Limited resistance |
Limited resistance |
|
- |
- |
Radiological resistance to UV radiation |
Resistant |
Resistant |
Product properties, functions, components General |
||
Product property |
||
|
No |
No |
|
Yes |
Yes |
Standards, specifications, approvals |
||
UL-Listing at 300 V rating |
Yes: CMG / CL3 / Sun Res |
Yes: CMG / CL3 / Sun Res |
UL-Style at 600 V rating |
Yes |
Yes |
Certificate of suitability |
- |
- |
|
Yes |
Yes |