Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru
IE FC TP Cable 2 x 2

Order No.

6XV1 840-2AH10

6XV1 870-2B

6XV1 870-2F

Product type designation

IE FC TP Standard Cable GP 2 x 2 (Type A)

IE FC TP Flexible Cable GP 2 x 2 (Type B)

IE TP Torsion Cable 2 x 2 (Type C)

Product description

Standard bus cable (4-core), sold by the meter, in bulk

Flexible bus cable (4-core), sold by the meter, in bulk

Highly flexible bus cable (4-core), sold by the meter, in bulk

Suitability for application

Standard cable with rigid cores for quick installation

For occasionally moved machine components

Continuous movement when using with robots

Cable designation

2YY (ST) CY 2x2x0.64/1.5-100 GN

2YY (ST) CY 2x2x0.75/1.5-100 LI GN

02YS C11Y 1x4x0.75/1.5-100 LI VZN FRNC GN

Cable length

-

-

-

Electrical specifications

Attenuation factor per length

  • At 10 MHz

52 dB/km

60 dB/km

81 dB/km

  • At 100 MHz

195 dB/km

210 dB/km

410 dB/km

Characteristic impedance at 1 MHz to 100 MHz

100 

100 

100 

Relative symmetrical tolerance of characteristic impedance at 1 MHz to 100 MHz

15 %

15 %

15 %

Near-end crosstalk per length at 1 MHz to 100 MHz

-

500 dB/km

500 dB/km

Surface transfer resistance at 10 MHz

10 m /m

20 m /m

100 m /m

Loop resistance per length

115  /km

120  /km

120  /km

Insulation resistance coefficient

-

-

-

Operating voltage, maximum

-

-

-

Mechanical data

Number of electrical cores

4

4

4

Design of shield

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Design of electrical connection FastConnect

Yes

Yes

No

AWG number

Diameter of AWG22 core

0.64 mm

0.75 mm

0.76 mm

Outer diameter

  • of inner conductor

0.64 mm

0.75 mm

0.76 mm

  • of core insulation

1.5 mm

1.5 mm

1.5 mm

  • of inner sheath of cable

3.9 mm

3.9 mm

-

  • of cable sheath

6.5 mm

6.5 mm

6.5 mm

Symmetrical tolerance of outer diameter of cable sheath

0.2 mm

0.2 mm

0.2 mm

Outer diameter of cable sheath - Note

-

-

-

Material

  • of core insulation

PE

PE

PE

  • of inner sheath of cable

PVC

PVC

-

  • of the cable sheath

PVC

PVC

PUR

    • Note

-

-

-

Color

  • of core insulation of data cores

white / yellow / blue / orange

white / yellow / blue / orange

white / yellow / blue / orange

  • of the cable sheath

Green

Green

Green

Bending radius

  • With single bending

19.5 mm

32.5 mm

32.5 mm

  • With repeated bending

49 mm

52 mm

65 mm

  • With continuous bending

-

-

-

Number of bending cycles

-

-

-

  • Note

-

-

Not suitable for festoon mounting

Number of torsion cycles with torsion by ± 180° on 1 m cable length

-

-

5 000 000

Maximum tensile load

150 N

150 N

130 N

Weight per length

67 kg/km

68 kg/km

54 kg/km

Permitted ambient conditions

Ambient temperature

  • During operation

-40 … +75 °C

-25 … +75 °C

-40 … +80 °C

  • During storage

-40 … +75 °C

-25 … +75 °C

-40 … +80 °C

  • During transport

-40 … +75 °C

-25 … +75 °C

-40 … +80 °C

  • During mounting

-20 … +60 °C

-10 … +60 °C

-20 … +60 °C

Ambient conditions for operation

-

-

-

IP degree of protection

-

-

-

Behavior in fire

Flame-retardant in accordance with UL 1685 (CSA FT 4)

Flame-retardant in accordance with UL 1685 (CSA FT 4)

Flame-retardant in accordance with IEC 60332-1-2

Chemical resistance

  • Mineral oil

Limited resistance

Limited resistance

resistant

  • Grease

Limited resistance

Limited resistance

resistant

  • Water

-

-

-

Radiological resistance to UV radiation

resistant

resistant

resistant

Product properties, functions, components General

Product property

  • Halogen-free

No

No

Yes

  • Silicon-free

Yes

Yes

Yes

Cable length for 100BaseTX with Industrial Ethernet

100 m

85 m

55 m

Standards, specifications, approvals

UL-Listing at 300 V rating

Yes: CM / CMG / PLTC / Sun Res

Yes: CM / CMG / PLTC / Sun Res

Yes: UL Style 21161

UL-Style at 600 V rating

Yes

No

No

Certificate of suitability

-

-

-

  • RoHS compliance

Yes

Yes

-

Standard for structured cabling

Cat5e

Cat5e

Cat5e

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

No

No

No

  • Bureau Veritas (BV)

No

No

No

  • Det Norske Veritas (DNV)

No

No

No

  • Germanischer Lloyd (GL)

No

No

No

  • Lloyds Register of Shipping (LRS)

No

No

No


Order No.

6XV1 870-2D

6XV1 840-3AH10

6XV1 871-2S

Product type designation

IE FC TP Trailing Cable GP 2 x 2 (Type C)

IE FC TP Trailing Cable 2 x 2 (Type C)

IE FC TP Festoon Cable GP 2 x 2 (Type B)

Product description

Highly flexible bus cable (4-core), sold by the meter, in bulk

Highly flexible bus cable (4-core), sold by the meter, in bulk

Flexible bus cable (4-core), sold by the meter, in bulk

Suitability for application

Continuous movement in a trailing cable

Continuous movement in a trailing cable

For continuous movement in a trailing cable, festoon mounting

Cable designation

2YY (ST) CY 2x2x0.75/1.5-100 LI GN

2YH (ST) C11Y 2x2x0.75/1.5-100 LI GN VZN FRNC

2YY (ST) CY 2x2x0.75/1.5 LI GN

Cable length

-

-

-

Electrical specifications

Attenuation factor per length

  • at 10 MHz

63 dB/km

60 dB/km

63 dB/km

  • At 100 MHz

213 dB/km

220 dB/km

213 dB/km

Characteristic impedance at 1 MHz ... 100 MHz

100 

100 

100 

Relative symmetrical tolerance of characteristic impedance at 1 MHz to 100 MHz

5 %

15 %

5 %

Near-end crosstalk per length at 1 MHz to 100 MHz

500 dB/km

-

500 dB/km

Surface transfer resistance at 10 MHz

20 m /m

10 m /m

0.1  /m

Loop resistance per length

0.12  /m

0.12  /m

0.12  /m

Insulation resistance coefficient

-

-

-

Operating voltage, maximum

-

-

-

Mechanical data

Number of electrical cores

4

4

4

Design of shield

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Design of electrical connection FastConnect

Yes

Yes

Yes

AWG number

Diameter of AWG22 core

0.75 mm

0.75 mm

0.75 mm

Outer diameter

  • of inner conductor

0.75 mm

0.75 mm

0.75 mm

  • of core insulation

1.5 mm

1.5 mm

1.5 mm

  • of inner sheath of cable

3.9 mm

3.9 mm

3.9 mm

  • of the cable sheath

6.5 mm

6.5 mm

6.5 mm

Symmetrical tolerance of outer diameter of cable sheath

0.2 mm

0.2 mm

0.2 mm

Outer diameter of cable sheath - Note

-

-

-

Material

  • of core insulation

PE

PE

PE

  • of inner sheath of cable

PVC

FRNC

PVC

  • of cable sheath

PVC

PUR

PVC

    • Note

-

-

-

Color

  • of core insulation of data cores

white / yellow / blue / orange

white / yellow / blue / orange

white / yellow / blue / orange

  • of the cable sheath

Green

Green

Green

Bending radius

  • with single bending

32.5 mm

19.5 mm

30 mm

  • With repeated bending

49 mm

49 mm

70 mm

  • With continuous bending

100 mm

100 mm

-

Number of bending cycles

3 000 000

4 000 000

5 000 000

  • Note

Suitable as trailing cable for 3 million bending cycles with a bending radius of 100 mm, a speed of 4 m/s, and an acceleration of 4 m/s .

Suitable as trailing cable for 4 million bending cycles with a bending radius of 100 mm.

5 million bending cycles with a bending radius of 70 mm, and an acceleration of 4 m/s .

Number of torsion cycles with torsion by ± 180° on 1 m cable length

-

-

-

Maximum tensile load

150 N

150 N

150 N

Weight per length

68 kg/km

63 kg/km

68 kg/km

Permitted ambient conditions

Ambient temperature

  • During operation

-25 … +75 °C

-40 … +75 °C

-40 … +75 °C

  • During storage

-25 … +75 °C

-50 … +75 °C

-50 … +75 °C

  • During transport

-25 … +75 °C

-50 … +75 °C

-50 … +75 °C

  • During mounting

-10 … +60 °C

-20 … +60 °C

-20 … +60 °C

Ambient conditions for operation

-

-

-

IP degree of protection

-

-

-

Behavior in fire

Flame-retardant in accordance with UL 1685 (CSA FT 4)

Flame-retardant in accordance with IEC 60332-1-2

Flame-retardant in accordance with UL 1685 (CSA FT 4)

Chemical resistance

  • against mineral oil

Limited resistance

resistant

Limited resistance

  • Grease

Limited resistance

resistant

Limited resistance

  • Water

-

-

-

Radiological resistance to UV radiation

resistant

resistant

resistant

Product properties, functions, components General

Product property

  • Halogen-free

No

Yes

No

  • Silicon-free

Yes

Yes

Yes

Cable length for 100BaseTX with Industrial Ethernet

85 m

85 m

85 m

Standards, specifications, approvals

UL listing at 300 V rating

Yes: CMG / PLTC / Sun Res

Yes: CMX

Yes: CMG / PLTC / Sun Res

UL-Style at 600 V rating

Yes

No

Yes

Certificate of suitability

-

-

-

  • RoHS compliance

Yes

Yes

Yes

Standard for structured cabling

Cat5e

Cat5e

Cat5e

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

No

No

No

  • Bureau Veritas (BV)

No

No

No

  • Det Norske Veritas (DNV)

No

No

No

  • Germanischer Lloyd (GL)

No

No

No

  • Lloyds Register of Shipping (LRS)

No

No

No


Order No.

6XV1 871-2F

6XV1 871-2L

6XV1 840-4AH10

Product type designation

IE FC TP FRNC Cable GP 2 x 2 (Type B)

IE FC TP Food Cable 2 x 2 (Type C)

IE FC TP Marine Cable 2 x 2 (Type B)

Product description

Flexible, halogen-free bus cable (4-core), sold by the meter, in bulk

Flexible bus cable (4-core), sold by the meter, in bulk

Bus cable (4-core), sold by the meter, in bulk

Suitability for application

For occasionally moved machine components

Food, beverages and tobacco industries

For marine and offshore use

Cable designation

L-9YH (ST) CH 2x2x0.34/1.5-100 GN VZN FRNC

2YH (ST) C2Y 2X2X0.75/1.5-100 LI

L-9YH (ST) CH 2 x 2 x 0.34/1.5-100 GN VZN FRNC

Cable length

-

-

-

Electrical specifications

Attenuation factor per length

  • at 10 MHz

60 dB/km

63 dB/km

60 dB/km

  • At 100 MHz

220 dB/km

213 dB/km

220 dB/km

Characteristic impedance at 1 MHz to 100 MHz

100 

100 

100 

Relative symmetrical tolerance of characteristic impedance at 1 MHz to 100 MHz

15 %

5 %

15 %

Near-end crosstalk per length at 1 MHz to 100 MHz

500 dB/km

500 dB/km

-

Surface transfer resistance at 10 MHz

10 m /m

10 m /m

10 m /m

Loop resistance per length

120  /km

120  /km

120  /km

Insulation resistance coefficient

-

-

-

Operating voltage, maximum

-

-

-

Mechanical data

Number of electrical cores

4

4

4

Design of shield

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires

Design of electrical connection FastConnect

Yes

Yes

Yes

AWG number

Diameter of AWG22 core

0.75 mm

0.75 mm

0.75 mm

Outer diameter

  • of inner conductor

0.75 mm

0.75 mm

0.75 mm

  • of core insulation

1.5 mm

1.5 mm

1.5 mm

  • of inner sheath of cable

3.9 mm

3.9 mm

3.9 mm

  • of the cable sheath

6.5 mm

6.5 mm

6.5 mm

Symmetrical tolerance of outer diameter of cable sheath

0.2 mm

0.2 mm

0.2 mm

Outer diameter of cable sheath - Note

-

-

-

Material

  • of core insulation

PP

PE

PP

  • of inner sheath of cable

FRNC

FRNC

FRNC

  • of cable sheath

FRNC

PE

FRNC

    • Note

-

-

-

Color

  • of core insulation of data cores

white / yellow / blue / orange

white / yellow / blue / orange

white / yellow / blue / orange

  • of the cable sheath

Green

Black

Green

Bending radius

  • with single bending

39 mm

20 mm

39 mm

  • With repeated bending

97.5 mm

49 mm

97.5 mm

  • With continuous bending

-

-

-

Number of bending cycles

-

-

-

  • Note

-

-

-

Number of torsion cycles with torsion by ± 180° on 1 m cable length

-

-

-

Maximum tensile load

150 N

150 N

150 N

Weight per length

68 kg/km

55 kg/km

68 kg/km

Permitted ambient conditions

Ambient temperature

  • During operation

-25 … +70 °C

-40 … +75 °C

-25 … +70 °C

  • During storage

-40 … +75 °C

-50 … +75 °C

-40 … +70 °C

  • During transport

-40 … +75 °C

-50 … +75 °C

-40 … +70 °C

  • During mounting

0 … 50 °C

-20 … +60 °C

0 … 50 °C

Ambient conditions for operation

-

-

-

IP degree of protection

-

-

-

Behavior in fire

Flame-retardant in accordance with IEC 60332-3-22 (Category A/F)

Flammable

Flame-retardant in accordance with IEC 60332-3-22 (Category A/F)

Chemical resistance

  • against mineral oil

Limited resistance

Limited resistance

Limited resistance

  • against grease

Limited resistance

Limited resistance

Limited resistance

  • against water

-

-

-

Radiological resistance to UV radiation

resistant

resistant

resistant

Product properties, functions, components General

Product property

  • Halogen-free

Yes

Yes

Yes

  • Silicon-free

Yes

Yes

Yes

Cable length for 100BaseTX with Industrial Ethernet

85 m

85 m

85 m

Standards, specifications, approvals

UL listing at 300 V rating

Yes: CMG / PLTC / Sun Res

No

No

UL-Style at 600 V rating

No

No

Yes: CM / CMG / PLTC / Sun Res

Certificate of suitability

-

-

-

  • RoHS compliance

Yes

Yes

Yes

Standard for structured cabling

Cat5e

Cat5e

Cat5e

Marine classification corporation

  • American Bureau of Shipping Europe Ltd. (ABS)

No

No

Yes

  • Bureau Veritas (BV)

No

No

Yes

  • Det Norske Veritas (DNV)

No

No

Yes

  • Germanischer Lloyd (GL)

No

No

Yes

  • Llyods Register of Shipping (LRS)

No

No

Yes
























































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET ECOFAST Введение Industrial Ethernet Введение Передача данных Обзор коммуникаций Топологии Критерии выбора типа сети Сетевые компоненты для Industrial Ethernet Обзор пассивных сетевых компонент Обзор по кабелям "витая пара" Технология FastConnect для Industrial Ethernet Штекер IE FC RJ45 Штекер IE FC RJ45 4 x 2 Штекеры IE Push Pull Plug PRO IE Соединительный кабель M12-180/M12-180 IE FC TP кабель 2 х 2 IE FC TP кабель 4 x 2 Гибридный кабель IE Цепи питания TP Cord Соединительные кабели IE M12-180/M12-180 Розетка RJ45 для Industrial Ethernet Модульный соединитель IE FC RJ45 Монтажный кабель ITP Обзор FC FOC оптических кабелей Стеклянные волоконно-оптические кабели быстрого монтажа FC FO монтажный комплект Оптические кабели Стеклянный волоконно-оптический кабель Оптические POF и PCF кабели Комплект для монтажа соединителей на POF/PCF FOC оптические кабели Industrial Ethernet коммутаторы Активные сетевые компоненты Безопасность передачи данных в промышленных сетях Системные интерфейсы Аксессуары Управление сетью Сетевые переходы Решения партнеров PROFINET PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366
Яндекс.Метрика