Plastic and PCF fiber-optic cable

Order No.

6XV1 821-2AN50

6XV1 821-0AH10

6XV1 821-1BN75

Product type designation

PROFIBUS Plastic Fiber Optic Duplex Core

PROFIBUS Plastic Fiber Optic Standard Cable

PROFIBUS PCF Fiber Optic Standard Cable

Product description

Fiber-optic cable with poly-optical fiber (flat duplex core), 50 m ring, non-assembled

Fiber-optic cable with poly-optical fiber, sold by the meter, non-assembled

Polymer cladded fiber cable, preferred length, preassembled

Suitability for application

Indoor applications with low mechanical stress (e.g. laboratory setups or within cabinets), cable lengths up to 50 m

Cable for indoor applications

Cable for indoor applications

Design of preassembled FO cable

Can be fitted with four Simplex connectors

Can be fitted with four Simplex connectors

Fitted with four BFOC connectors

Cable designation

V-2Y 2x1 P 980/1000

I-V4Y(ZN)Y 2P 980/1000

I-V(ZN)Y 2K 200/230

Cable length

50 m

-

75 m

Optical data

Maximum damping factor per length at 650 nm

0.01 dB/m

0.16 dB/m

0.01 dB/m

Bandwidth length product at 650 nm

1 GHz·m

1 GHz·m

17 GHz·m

Mechanical data

Number of fibers per FO core

1

1

1

Number of FO cores per FO cable

2

2

2

Design of FO fiber

Step index fiber 980/1000 µm

Step index fiber 980/1000 µm

Step index fiber 200/230 µm

Design of FO core

-

-

-

Design of FO cable

-

-

-

Outer diameter

  • of optical fiber

980 µm

980 µm

200 µm

  • of optical fiber sheath

1 000 µm

1 000 µm

230 µm

  • of FO core sheath

2.2 mm

2.2 mm

2.2 mm

  • of cable

-

7.8 mm

4.7 mm

Symmetrical deviation

  • of outer diameter of FO core sheath

0.1 mm

0.1 mm

0.1 mm

  • of outer diameter of cable

-

0.3 mm

-

Width of cable sheath

-

-

-

Symmetrical tolerance of cable sheath width

-

-

-

Thickness of cable sheath

-

-

-

Symmetrical tolerance of cable sheath thickness

-

-

-

Material

  • of optical fiber core

Polymethylmethacrylate (PMMA)

Polymethylmethacrylate (PMMA)

Quartz glass

  • of optical fiber sheath

Fluoridated special polymer

Fluoridated special polymer

Fluoridated special polymer

  • of FO core sheath

PE

PA

PVC

  • of FO cable sheath

-

PVC

PVC

  • of the strain relief

-

Kevlar fibers

Kevlar fibers

Color

  • of FO core sheath

Gray

Orange/black

Orange/black

  • of cable sheath

-

Violet

Violet

Bending radius

  • Minimum permitted single bending radius

25 mm

100 mm

47 mm

  • Minimum permitted repeated bending radius

25 mm

150 mm

70 mm

  • With continuous bending

-

-

-

Number of bending cycles

-

-

-

Maximum tensile load

10 N

100 N

200 N

Short-term lateral force per length

30 N/cm

100 N/cm

100 N/cm

Continuous lateral force per length

400 N/m

-

-

Weight per length

7.6 kg/km

65 kg/km

22 kg/km

Permitted ambient conditions

Ambient temperature

  • During operation

-55 … +85 °C

-30 … +70 °C

-30 … +70 °C

  • During storage

-55 … +85 °C

-30 … +70 °C

-30 … +70 °C

  • During transport

-55 … +85 °C

-30 … +70 °C

-30 … +70 °C

  • During mounting

-5 … +50 °C

0 … 50 °C

-5 … +50 °C

Ambient conditions for operation

-

-

-

IP degree of protection

-

-

IP20

Behavior in fire

Flame-retardant in accordance with flame test VW-1 acc. to UL 1581

Flame-retardant in accordance with IEC 60332-1-2

Flame-retardant in accordance with IEC 60332-1-2

Chemical resistance

  • Mineral oil

Limited resistance

Limited resistance

Limited resistance

  • Grease

Limited resistance

Limited resistance

Limited resistance

  • Water

-

-

-

Radiological resistance against UV radiation

Not resistant

Not resistant

Not resistant

Product properties, functions, componentsGeneral

Product property

  • Halogen-free

Yes

No

No

  • Silicon-free

Yes

Yes

Yes

Product component: protection against rodents

No

No

No

Cable length with plastic optical fiber

  • Maximum with Industrial Ethernet

-

-

-

  • Maximum with PROFIBUS

80 m

80 m

-

Standards, specifications, approvals

Certificate of suitability

-

UL approval: OFN (NEC Article 770, UL 1651) / CSA approval: OFN (CSA standard C22.2 No232-M1988)

-

  • RoHS compliance

Yes

Yes

Yes


Order No.

6XV1 861-2A

6XV1 861-2C

6XV1 861-2D

Product type designation

PCF Standard Cable GP

PCF Trailing Cable

PCF Trailing Cable GP

Product description

Polymer cladded fiber cable, sold by the meter, non-assembled

Polymer cladded fiber cable, sold by the meter, non-assembled

Polymer cladded fiber cable, sold by the meter, non-assembled

Suitability for application

Cable for fixed installation for indoor and outdoor use, UL approval

Cable for use with high mechanical stress and moving applications (e.g. trailing cables), without UL approval

Cable for use with high mechanical stress and moving applications (e.g. trailing cables), UL approval

Design of preassembled FO cable

Can be fitted with SC RJ, SC RJ Plug PRO, BFOC and Simplex connectors

Can be fitted with SC RJ, SC RJ Plug PRO, BFOC and Simplex connectors

Can be fitted with SC RJ, SC RJ Plug PRO, BFOC and Simplex connectors

Cable designation

AT-V(ZN)YY 2K 200/230

AT-V(ZN)Y(ZN)11Y 2K 200/230

AT-V(ZN)Y(ZN)Y 2K 200/230

Cable length

-

-

-

Optical data

Maximum damping factor per length at 660 nm

10 dB/km

10 dB/km

10 dB/km

Bandwidth length product at 650 nm

17 GHz·m

17 GHz·m

17 GHz·m

Mechanical data

Number of fibers per FO core

1

1

1

Number of FO cores per FO cable

2

2

2

Design of FO fiber

Step index fiber 200/230 µm

Step index fiber 200/230 µm

Step index fiber 200/230 µm

Design of FO core

-

-

-

Design of FO cable

-

-

-

Outer diameter

  • of optical fiber

200 µm

200 µm

200 µm

  • of optical fiber sheath

230 µm

230 µm

230 µm

  • of FO core sheath

2.2 mm

2.2 mm

2.2 mm

  • of cable

7.2 mm

8.8 mm

8.8 mm

Symmetrical deviation

  • of outer diameter of FO core sheath

0.1 mm

0.1 mm

0.1 mm

  • of outer diameter of cable

0.5 mm

0.5 mm

0.5 mm

Width of cable sheath

-

-

-

Symmetrical tolerance of cable sheath width

-

-

-

Thickness of cable sheath

-

-

-

Symmetrical tolerance of cable sheath thickness

-

-

-

Material

  • of optical fiber core

Quartz glass

Quartz glass

Quartz glass

  • of optical fiber sheath

Special polymer

Special polymer

Special polymer

  • of FO core sheath

PVC

PVC

PVC

  • of FO cable sheath

PVC

PUR

PVC

  • of the strain relief

Aramide fibers

Aramide fibers

Aramide fibers

Color

  • of FO core sheath

Orange/black

Orange/black

Orange/black

  • of cable sheath

Green

Green

Green

Bending radius

  • Minimum permitted single bending radius

70 mm

130 mm

130 mm

  • Minimum permitted repeated bending radius

105 mm

175 mm

175 mm

  • With continuous bending

-

-

-

Number of bending cycles

-

5 000 000

5 000 000

Maximum tensile load

100 N

800 N

800 N

Short-term lateral force per length

500 N/cm

500 N/cm

500 N/cm

Continuous lateral force per length

300 N/cm

300 N/cm

300 N/cm

Weight per length

45 kg/km

85 kg/km

85 kg/km

Permitted ambient conditions

Ambient temperature

  • During operation

-40 … +90 °C

-25 … +75 °C

-25 … +75 °C

  • During storage

-40 … +90 °C

-30 … +75 °C

-30 … +75 °C

  • During transport

-40 … +90 °C

-30 … +75 °C

-30 … +75 °C

  • During mounting

-5 … +50 °C

-5 … +50 °C

-5 … +50 °C

Ambient conditions for operation

-

-

-

IP degree of protection

-

-

-

Behavior in fire

Flame-retardant in accordance with IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)

Flame-retardant

Flame-retardant in accordance with IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)

Chemical resistance

  • Mineral oil

Limited resistance

Resistant

Limited resistance

  • Grease

Limited resistance

Resistant

Limited resistance

  • Water

-

-

-

Radiological resistance against UV radiation

Resistant

Resistant

Resistant

Product properties, functions, componentsGeneral

Product property

  • Halogen-free

No

No

No

  • Silicon-free

Yes

Yes

Yes

Product component: protection against rodents

No

No

No

Cable length with polymer cladded fiber

  • Maximum with Industrial Ethernet

100 m

100 m

100 m

  • Maximum with PROFIBUS

400 m

400 m

400 m

Standards, specifications, approvals

Certificate of suitability

UL approval: OFN (NEC Article 770, UL 1651) / CSA approval: OFN 90 Cel, FT1, FT4 (CSA standard C22.2 No232-M1988)

-

UL approval: OFN (NEC Article 770, UL 1651) / CSA approval: OFN 90 Cel, FT1, FT4 (CSA standard C22.2 No232-M1988)

  • RoHS compliance

Yes

Yes

Yes


Order No.

6GK1 905-1PA00

Product type designation

PB BFOC Plug POF

Product description

BFOC connector

Suitability for application

For assembly of PB plastic fiber optic cables for OLM/P.

Transmission rate

Transmission rate

  • 1 with Industrial Ethernet

-

  • 2 with Industrial Ethernet

-

  • 3 with Industrial Ethernet

-

  • with PROFIBUS

9.6 Kbit/s … 12 Mbit/s

Interfaces

Number of optical connections for fiber-optic cables

1

Number of optical connections for network components or terminals

BFOC connector

Design of electrical connection FastConnect

No

Mechanical data

Enclosure material

Metal

Design, dimensions and weights

Type of cable outlet

180 degree cable outlet

Width

10 mm

Height

10 mm

Depth

10 mm

Net weight

10 g

Permitted ambient conditions

Ambient temperature

  • During operation

- -

  • During storage

- -

  • During transport

- -

Relative humidity at 25 °C without condensation during operation, maximum

-

IP degree of protection

IP20

Chemical resistance to water

-

Product properties, functions, componentsGeneral

Product property silicon-free

Yes

Product component strain relief

Yes

Standards, specifications, approvals

Certificate of suitability: RoHS conformity

Yes
























































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET ECOFAST Введение Industrial Ethernet PROFINET PROFIBUS Введение Полевая шина и передача данных процессов Передача данных Communication overview Примеры конфигураций Топологии Сетевые компоненты для PROFIBUS Обзор сетевых компонент Критерии выбора типа сети Примеры соединений Электрические сети (RS485) Электрические сети (PROFIBUS-PA) Электрические сети FOUNDATION Fieldbus Оптические сети с OLM Обзор FC FOC оптических кабелей Стеклянные волоконно-оптические кабели быстрого монтажа FC FO монтажный комплект Стеклянный волоконно-оптический кабель Пластиковые и PCF волоконно-оптический кабели Набор инструментов для монтажа PCF FOC Модули OLM Оптические модули связи SIPLUS OLM Оптические сети с ОВТ и встроенными интерфейсами Беспроводные соединения Системные интерфейсы Сетевые переходы Управление в промышленности Приборы коммутации и защиты для распределения энергии Система управления потреблением энергии Устройства с PROFIBUS-DP RFID системы - коммуникационные модули Датчики Инжиниринговые пакеты Технологические компоненты для PROFIBUS Решения партнеров AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо