Unless explicitly specified otherwise, the following technical specifications are valid for all the following components of the SINAMICS G120D distributed inverter listed here.
SINAMICS G120D |
|
---|---|
Mechanical specifications |
|
Vibratory load according to EN 60068 2 6 |
|
|
5 … 9 Hz: Constant deflection 3.1 mm |
|
10 … 58 Hz: Constant delfection 0.15 mm |
Schockbeanspruchung nach EN 60068 2 27 |
|
|
147.15 m/s2 (15 g)/11 ms |
|
147,15 m/s2 (15 g)/11 ms |
Ambient conditions |
|
Protection class acc. to EN 61800 5 1 |
Class III (PELV) |
Touch protection according to EN 61800 5 1 |
Class I (with protective conductor system) |
Permissible ambient and coolant temperature (air) during operation for Power Modules |
-10 … +40 °C ohne Derating |
Permissible ambient and coolant temperature (air) during operation for Control Units |
CU240D DP: -10 … +55 °C (> 40 ... 55 °C see derating characteristics) |
Climatic ambient conditions |
|
|
Temperature -40 … +70 °C |
|
Temperature -40 … +70 °C |
|
Temperature -10 … +40 °C without derating |
Environmental class/harmful chemical substances |
|
|
Class 3C2 |
Degree of pollution acc. to EN 61800 5 1 |
2 |
Certification for Fail-Safe versions |
|
|
3 |
|
2 |
|
i. V. |
|
5 10-8 |
|
10 years |
Standards |
|
Compliance with standards |
UL 508C (UL-Listennummer E121068), CE, c-tick |
CE mark |
According to Low-Voltage Directive 73/23/EWG and Machinery Directive 98/37/EG |
EMC-Directive2) |
|
|
Category C23) acc. to EN 61800 3 (corresponds to class A acc. to EN 55011) |
Note: The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter. The frequency inverters on their own do not generally require identification according to the EMC Directive.. |
1) In transport packaging.
2) For further general information, see also SINAMICS G110section Technical specifications, Compliance with standards