SINAMICS G120D distributed inverters

Unless explicitly specified otherwise, the following technical specifications are valid for all the following components of the SINAMICS G120D distributed inverter listed here.

SINAMICS G120D

Mechanical specifications

Vibratory load according to EN 60068 2 6

  • Transport 1)

5 … 9 Hz: Constant deflection 3.1 mm
9 … 200 Hz: Constant acceleration = 9.81 m/s2 (1   g)

  • Operation

10 … 58 Hz: Constant delfection 0.15 mm
58 … 200 Hz: Constant acceleration = 19.62 m/s2 (2   g)

Schockbeanspruchung nach EN 60068 2 27

  • Transport 1)

147.15 m/s2 (15   g)/11 ms
3 Shocks in each axis and direction

  • Betrieb

147,15 m/s2 (15   g)/11 ms
3 Shocks in each axis and direction

Ambient conditions

Protection class acc. to EN 61800 5 1

Class III (PELV)

Touch protection according to EN 61800 5 1

Class I (with protective conductor system)

Permissible ambient and coolant temperature (air) during operation for Power Modules

-10 … +40 °C ohne Derating
> 40 … 55 °C siehe Derating-Kennlinien

Permissible ambient and coolant temperature (air) during operation for Control Units

CU240D DP: -10 … +55 °C
CU240D PN: -10 … +50 °C
CU240D DP F: 0 … 55 °C
CU240D PN F: 0 … 50 °C

(> 40 ... 55 °C see derating characteristics)
up to 2000 m above sea level

Climatic ambient conditions

  • Storage 1) acc. to EN 60068 2 1

Temperature -40 … +70 °C

  • Transport 1) acc. to EN 60068 2 1

Temperature -40 … +70 °C
max. humidity 95 % at 40 °C

  • Operation acc. to EN 60068 2 2

Temperature -10 … +40 °C without derating

Environmental class/harmful chemical substances

  • Operation acc. to EN 60721 3 3

Class 3C2

Degree of pollution acc. to EN 61800 5 1

2

Certification for Fail-Safe versions

  • Category acc. to EN 954 1

3

  • SIL Cl acc. to IEC 61508

2

  • PL acc. to ISO 13849

i. V.

  • PFHD

5   10-8

  • T1

10 years

Standards

Compliance with standards

UL 508C (UL-Listennummer E121068), CE, c-tick

CE mark

According to Low-Voltage Directive 73/23/EWG and Machinery Directive 98/37/EG

EMC-Directive2)

  • Frame sizes FSA to FSC with integrated Class A line filter

Category C23) acc. to EN 61800 3 (corresponds to class A acc. to EN 55011)

Note: The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter. The frequency inverters on their own do not generally require identification according to the EMC Directive..