Double Motor Modules feature the following connections and interfaces as standard:
- 2 DC link connections via integrated DC link busbars
- 2 electronics power supply connections via integrated 24 V DC bars
- 4 DRIVE CLiQ sockets
- 2 motor connections via connector
- 2 safe standstill inputs (1 input per axis)
- 2 safe motor brake controllers
- 2 temperature sensor inputs (KTY84 130 or PTC)
- 3 PE/protective conductor connections
The status of the Motor Modules is indicated via two multi-color LEDs.
The shield of the motor cables is connected via the motor connectors.
The signal cable shield can be connected to the Motor Module by means of a shield connection terminal, e.g. type KLBU 3 8 SC by Weidmuller.
The scope of supply of the Motor Modules includes:
- DRIVE-CLiQ cable for connecting to the adjacent Motor Module, length 0.16 m
- 2 blanking plugs for sealing unused DRIVE CLiQ sockets
- Jumper for connecting the 24 V DC busbar to the adjacent Motor Module
- Connectors X21 and X22
- Connectors X1 and X2 for motor connection
- 1 set of warning signs in foreign languages
- 1 heat conducting foil