Mode of operation |
|
---|---|
Measuring principle |
Radar level measurement |
Frequency |
78 GHz FMCW |
Minimum detectable distance |
400 mm (15.75") from sensor reference point |
Maximum measuring range1) |
|
Output |
|
|
4 to 20 mA |
|
|
|
|
Performance (according to reference conditions IEC60770-1) |
|
|
|
Rated operating conditions (according to reference conditions IEC60770-1) |
|
Installation conditions |
|
|
Indoor/outdoor |
Ambient conditions (enclosure) |
|
|
-40 to +80 °C (-40 to +176 °F) |
|
I |
|
4 |
Medium conditions |
|
|
>2.0 |
Process temperature and pressure |
See chart below |
Design |
|
|
|
|
316L/1.4404 stainless steel |
|
M20x1.5, or " NPT via adapter |
|
|
|
Type 4X/NEMA 4X, Type 6/NEMA 6, IP68 with lid closed |
|
3.15 kg (6.94 lb) including 3" flange |
|
Graphic LCD, with bar graph representing level |
Process connections |
|
Universal flat-faced flanges2) |
|
Aimer flanges2) |
3, 4, 6"/80, 100, 150 mm, polyurethane powder-coated cast aluminum |
Power supply |
|
4 ... 20 mA/HART |
Nominal 24 V DC (max. 30 V DC) with max. 550 |
PROFIBUS PA/Foundation Fieldbus |
13.5 mA |
Certificates and approvals |
|
|
CSAUS/C, CE, FM |
|
Europe (R&TTE), FCC, Industry Canada, C-TICK |
|
|
|
IECEx SIR 09.0149X |
|
FM/CSA Class II, Div. 1, Groups E, F, G |
|
NEPSI |
|
INMETRO BR-Ex nA/nL II T4 IP68 |
Programming |
|
|
Infrared receiver |
|
IS model: |
|
HART communicator 375/475 |
|
SIMATIC PDM, AMS, PACTware |
|
Graphic local user interface including quick start wizard and echo profile displays |
1) From sensor reference point
2) Universal flange mates with EN 1092-1 (PN16)/ASME B16.5 (150 lb)/JIS 2220 (10K) bolt hole pattern.
®HART is a registered trademark of the Hart Communications Foundation.
Process temperature and pressure
Version |
Stainless steel |
Aimer flange: |
Aimer flange: |
---|---|---|---|
40 m |
-40 to +100 °C |
-40 to +100 °C |
-40 to +100 °C |
100 m |
-40 to +200 °C |
-40 to +200 °C |
-40 to +120 °C |