SITRANS P280 WirelessHART Pressure Transmitter |
|
Mode of operation |
|
Measuring principle |
piezo-resistive |
Measured variable |
Gauge and absolute pressure |
Gauge pressure input |
|
Measuring range |
Overload limit/Bursting pressure |
0 ... 2 bar g (0 ... 29 psi) |
5 bar g (72.5 psi g) |
0 ... 10 bar g (0 ... 145 psi) |
50 bar g (363 psi g) |
0 ... 50 bar g (0 ... 725 psi) |
250 bar g (1740 psi g) |
0 ... 200 bar g (0 ... 2900 psi) |
650 bar g (7250 psi g) |
0 ... 400 bar g (0 ... 5800 psi) |
650 bar g (7250 psi g) |
Units |
mbar, bar, mmH2O, inH2O, atm, Torr, gcm , kgcm , mPa, KPa, Pa, psi, mmHG, mmH2O, ftH2O, inHG, inH2O |
Absolute pressure input |
|
Measuring range |
Overload limit/Bursting pressure |
0 ... 2 bar a (0 ... 29 psi a) |
5 bar a (72.5 psi a) |
0 ... 10 bar a (0 ... 145 psi a) |
50 bar a (363 psi a) |
0 ... 50 bar a (0 ... 725 psi a) |
250 bar a (1740 psi a) |
0 ... 200 bar a (0 ... 2900 psi a) |
650 bar a (7250 psi a) |
0 ... 400 bar a (0 ... 5800 psi a) |
650 bar a (7250 psi a) |
Units |
mbar, bar, mmH2O, inH2O, atm, Torr, gcm , kgcm , mPa, KPa, Pa, psi, mmHG, mmH2O, ftH2O, inHG, inH2O |
Output |
|
Output signal |
2.4 GHz Wireless signal with TSMP (Time Synchronized Mesh Protocol) |
Measuring accuracy |
According to IEC 60770-1 |
Error in measurement at limit setting incl. hysteresis and reproducibility |
typically 0.17 % of span, max. 0.25 % of sensor span |
Long-term stability |
max. ± 0.25 % of sensor/year span |
Influence of ambient temperature |
max. typically 0.07 %/10K, max. 0.2 %/10K of span of sensor |
Rated conditions |
|
Ambient conditions |
|
|
-40 ... +80 °C (-40 ... +176 °F) (in ambient temperatures below -20 °C (-4 °F) and above +70 °C (158 °F), readability of the display is limited.) |
|
-40 ... +85 °C (-40 ... +185 °F) |
|
< 95 % |
Climatic class |
4K4H in accordance with EN 60721-3-4(stationary use at locations not protected against weather) |
Degree of protection |
IP65/NEMA 4 |
Permissible medium temperature |
-40 ... 85 °C (-40 ... +185 °F) |
Design |
|
Enclosure material |
low-copper die-cast aluminum, GD-AISi12 |
Shock resistance |
in accordance with EN 60068-2-29 / 03.95 |
Resistance to vibration |
in accordance with EN 60068-2-6/ 12.07 20 f 2000 Hz 0.01 g /Hz |
Weight |
|
without battery |
1.5 kg (3.31 lb) |
With battery |
1.6 kg (3.53 lb) |
Dimensions (W x H x D) |
See Dimensional drawing |
Process connection |
|
Sensor break |
Is recognized |
Displays and controls |
|
Display (with illumination) |
|
|
104 x 80 pixels |
|
adjustable |
|
adjustable |
Setting options |
|
Auxiliary power supply |
|
Battery |
3.6 V DC |
Communication |
|
Radio |
WirelessHART V7.1 conforming |
Transmission frequency band |
2.4 GHz (ISM-Band) |
Transmission range under reference conditions |
Up to 250 m (line of sight) in outside areas Up to 50 m (greatly dependent on obstacles) in inside areas |
Communication interfaces |
|
Certificates and approvals |
|
Wireless communication approvals |
R&TTE FCC |
Classification according to pressure equipment directive (PED 97/23/EC) |
Gases: Fluid group 1 Liquids: Fluid group 1; meets requirements as per Section 3, Subsection 3 (good engineering practice) |