6ES7 315-6FF04-0AB0 |
|
Product version |
|
Hardware product version |
01 |
Firmware version |
V3.3 |
General information |
|
associated programming package |
STEP 7 V5.5 + SP1 or higher or STEP7 V5.2 + SP1 or higher with HSP 218 + Distributed Safety |
Supply voltage |
|
24 V DC |
Yes |
Input current |
|
Current consumption (rated value) |
850 mA |
Current consumption (in no-load operation), typ. |
150 mA |
Inrush current, typ. |
3.5 A |
I t |
1 A ·s |
Power losses |
|
Power loss, typ. |
4.5 W |
Memory |
|
Work memory |
|
|
384 Kibyte |
|
No |
|
128 Kibyte |
Load memory |
|
|
Yes |
|
8 Mbyte |
|
10 a |
Backup |
|
|
Yes; Guaranteed by MMC (maintenance-free) |
|
Yes; Program and data |
CPU-blocks |
|
Number of blocks (total) |
1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
DB |
|
|
1 024; Number range: 1 to 16000 |
|
64 Kibyte |
FB |
|
|
1 024; Number range: 0 to 7999 |
|
64 Kibyte |
FC |
|
|
1 024; Number range: 0 to 7999 |
|
64 Kibyte |
OB |
|
|
64 Kibyte |
Nesting depth |
|
|
16 |
|
4 |
CPU processing times |
|
for bit operations, min. |
0.05 µs |
for word operations, min. |
0.09 µs |
for fixed point arithmetic, min. |
0.12 µs |
for floating point arithmetic, min. |
0.45 µs |
Counters, timers and their retentivity |
|
S7 counter |
|
|
256 |
|
|
|
Yes |
|
0 |
|
255 |
|
Z 0 to Z 7 |
|
|
|
0 |
|
999 |
IEC counter |
|
|
Yes |
|
SFB |
|
Unlimited (limited only by RAM capacity) |
S7 times |
|
|
256 |
|
|
|
Yes |
|
0 |
|
255 |
|
No retentivity |
|
|
|
10 ms |
|
9 990 s |
IEC timer |
|
|
Yes |
|
SFB |
|
Unlimited (limited only by RAM capacity) |
Data areas and their retentivity |
|
retentive data area, total |
All, 128 KB max. |
Flag |
|
|
2 048 byte |
|
Yes; MB 0 to MB 2047 |
|
MB 0 to MB 15 |
|
8; 1 memory byte |
Data blocks |
|
|
Yes; via non-retain property on DB |
|
Yes |
Local data |
|
|
32 Kibyte; Max. 2 KB per block |
Address area |
|
I/O address area |
|
|
2 048 byte |
|
2 048 byte |
|
|
|
2 048 byte |
|
2 048 byte |
Process image |
|
|
2 048 byte |
|
2 048 byte |
|
384 byte |
|
384 byte |
Subprocess images |
|
|
1 |
Digital channels |
|
|
16 384 |
|
16 384 |
|
1 024 |
|
1 024 |
Analog channels |
|
|
1 024 |
|
1 024 |
|
256 |
|
256 |
Hardware configuration |
|
Racks, max. |
4 |
Modules per rack, max. |
8 |
Expansion devices, max. |
3 |
Number of DP masters |
|
|
1 |
|
4 |
Number of operable FMs and CPs (recommended) |
|
|
8 |
|
8 |
|
10 |
Time of day |
|
Clock |
|
|
Yes |
|
Yes |
|
10 s; Typ.: 2 s |
|
6 wk; At 40 °C ambient temperature |
|
Clock continues running after POWER OFF |
|
Clock continues to run with the time at which the power failure occurred |
Operating hours counter |
|
|
1 |
|
0 |
|
0 to 2^31 hours (when using SFC 101) |
|
1 hour |
|
Yes; Must be restarted at each restart |
Clock synchronization |
|
|
Yes |
|
Yes |
|
Yes |
|
Yes; With DP slave only slave clock |
|
Yes |
|
Yes |
|
No |
1st interface |
|
Type of interface |
Integrated RS 485 interface |
Physics |
RS 485 |
Isolated |
No |
Power supply to interface (15 to 30 V DC), max. |
200 mA |
Functionality |
|
|
Yes |
|
No |
|
No |
|
No |
MPI |
|
|
|
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes; Only server, configured on one side |
|
No |
|
Yes |
|
187.5 kbit/s |
2nd interface |
|
Type of interface |
Integrated RS 485 interface |
Physics |
RS 485 |
Isolated |
Yes |
Power supply to interface (15 to 30 V DC), max. |
200 mA |
Functionality |
|
|
No |
|
Yes |
|
Yes |
|
No |
DP master |
|
|
|
|
Yes |
|
No |
|
Yes; I blocks only |
|
Yes; Only server, configured on one side |
|
No |
|
Yes |
|
Yes |
|
Yes; OB 61 |
|
Yes |
|
Yes |
|
8 |
|
Yes |
|
12 Mbit/s |
|
124; Per station |
|
|
|
2 048 byte |
|
2 048 byte |
|
|
|
244 byte |
|
244 byte |
DP slave |
|
|
|
|
Yes |
|
No |
|
No |
|
Yes; Only server, configured on one side |
|
No |
|
Yes |
|
Yes |
|
No |
|
The latest GSD file is available at: http://www.siemens.de/profibus-gsd |
|
12 Mbit/s |
|
Yes; only with passive interface |
|
|
|
244 byte |
|
244 byte |
|
32 |
|
32 byte |
Communication functions |
|
PG/OP communication |
Yes |
Data record routing |
Yes |
Global data communication |
|
|
Yes |
|
8 |
|
8 |
|
8 |
|
8 |
|
22 byte |
|
22 byte |
S7 basic communication |
|
|
Yes |
|
76 byte |
|
76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication |
|
|
Yes |
|
Yes |
|
Yes; Via CP and loadable FB |
|
180 byte; With PUT/GET |
|
240 byte; as server |
S5-compatible communication |
|
|
Yes; via CP and loadable FC |
S7 message functions |
|
Number of login stations for message functions, max. |
16; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages |
Yes |
simultaneously active Alarm-S blocks, max. |
300 |
Test commissioning functions |
|
Status/control |
|
|
Yes |
|
Inputs, outputs, memory bits, DB, times, counters |
|
30 |
|
30 |
|
14 |
Forcing |
|
|
Yes |
|
Inputs, outputs |
|
10 |
Status block |
Yes; Up to 2 simultaneously |
Single step |
Yes |
Number of breakpoints |
4 |
Diagnostic buffer |
|
|
Yes |
|
500 |
|
No |
|
100; Only the last 100 entries are retained |
|
|
|
Yes; From 10 to 499 |
|
10 |
Isochronous mode |
|
Isochronous mode |
Yes |
Ambient conditions |
|
Operating temperature |
|
|
0 °C |
|
60 °C |
Configuration |
|
programming |
|
|
|
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
Yes |
|
see instruction list |
|
8 |
Know-how protection |
|
|
Yes |
|
Yes; With S7 block Privacy |
Dimensions |
|
Width |
40 mm |
Height |
125 mm |
Depth |
130 mm |
Weight |
|
Weight, approx. |
290 g |