Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru
SCALANCE X-300EEC managed

Order No.

6GK5 302-7GD00-1EA3

6GK5 302-7GD00-1GA3

6GK5 302-7GD00-2EA3

6GK5 302-7GD00-2GA3

Product type designation

SCALANCE X302-7 EEC

SCALANCE X302-7 EEC

SCALANCE X302-7 EEC

SCALANCE X302-7 EEC

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

9

9

9

9

Number of electrical connections

  • for network components and terminal equipment

2

2

2

2

  • for operator console

-

-

-

-

  • for alarm contact

1

1

2

2

  • for media module

-

-

-

-

  • for power supply

1

1

2

2

  • for redundant power supply

1

1

2

2

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

  • for operator console

-

-

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

2 x 4-pole terminal block

2 x 4-pole terminal block

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

7

7

7

7

  • at 1000 Mbit/s

-

-

-

-

Design of optical interface for optical waveguide

  • at 100 Mbit/s

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

  • at 1000 Mbit/s

-

-

-

-

Connectable optical power relative to 1 mW

  • of the transmitter output

-19 … -14 dB

-19 … -14 dB

-19 … -14 dB

-19 … -14 dB

  • of the receiver input maximum

-14 dB

-14 dB

-14 dB

-14 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-32 dB

-32 dB

-32 dB

-32 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 … 5 km

0 … 5 km

0 … 5 km

0 … 5 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

Operating voltage of signaling contacts at AC rated value

-

-

-

-

Operating current of signaling contacts at AC maximum

-

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of supply voltage redundant power supply unit

No

No

Yes

Yes

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage at AC

-

-

-

-

  • rated value

- -

- -

- -

- -

Type of voltage 2 of the supply voltage

DC

DC

DC

DC

Supply voltage for DC

24 V

24 V

24 V

24 V

  • rated value

19.2 … 57.6 V

19.2 … 57.6 V

19.2 … 57.6 V

19.2 … 57.6 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.75 A

0.75 A

0.75 A

0.75 A

Active power loss

  • at 24 V for DC

17 W

17 W

17 W

17 W

  • at 230 V AC

-

-

-

-

  • at 250 V with DC

-

-

-

-

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

Conformal coating

-

Conformal coating

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Compact

Compact

Width

60 mm

60 mm

60 mm

60 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

123 mm

123 mm

123 mm

123 mm

Net weight

1.8 kg

1.8 kg

2.03 kg

1.8 kg

Type of mounting

  • Installation 19 inch

Yes

Yes

Yes

Yes

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

No

No

No

No

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

Yes

Yes

Yes

Yes

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

Standard

  • for EMC

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

  • for safety of CSA and UL

UL 508

UL 508

UL 508

UL 508

  • for hazardous area of CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50124-1

No

No

No

No

  • IEC 61850-3

Yes

Yes

Yes

Yes

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

-

-

-

-

  • Bureau Veritas (BV)

-

-

-

-

  • Det Norske Veritas (DNV)

-

-

-

-

  • Germanische Lloyd (GL)

-

-

-

-

  • Lloyds Register of Shipping (LRS)

-

-

-

-

  • Nippon Kaiji Kyokai (NK)

-

-

-

-


Order No.

6GK5 302-7GD00-3EA3

6GK5 302-7GD00-3GA3

6GK5 302-7GD00-4EA3

6GK5 302-7GD00-4GA3

Product type designation

SCALANCE X302-7 EEC

SCALANCE X302-7 EEC

SCALANCE X302-7 EEC

SCALANCE X302-7 EEC

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

9

9

9

9

Number of electrical connections

  • for network components and terminal equipment

2

2

2

2

  • for operator console

-

-

-

-

  • for alarm contact

1

1

2

2

  • for media module

-

-

-

-

  • for power supply

1

1

1

1

  • for redundant power supply

-

-

1

1

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

  • for operator console

-

-

-

-

  • for signaling contact

3-pole terminal block

3-pole terminal block

3-pole terminal block

3-pole terminal block

  • for power supply

3-pole terminal block

3-pole terminal block

2 x 3-pole terminal block

2 x 3-pole terminal block

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

7

7

7

7

  • at 1000 Mbit/s

-

-

-

-

Design of optical interface for optical waveguide

  • at 100 Mbit/s

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

  • at 1000 Mbit/s

-

-

-

-

Connectable optical power relative to 1 mW

  • of the transmitter output

-19 … -14 dB

-19 … -14 dB

-19 … -14 dB

-19 … -14 dB

  • of the receiver input maximum

-14 dB

-14 dB

-14 dB

-14 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-32 dB

-32 dB

-32 dB

-32 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 … 5 km

0 … 5 km

0 … 5 km

0 … 5 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

Operating voltage of signaling contacts at AC rated value

276 V

276 V

276 V

276 V

Operating current of signaling contacts at AC maximum

5 A

5 A

5 A

5 A

Operating voltage of signaling contacts at DC rated value

230 V

230 V

230 V

230 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of supply voltage redundant power supply unit

No

No

Yes

Yes

Type of voltage of supply voltage

AC

AC

AC

AC

Supply voltage at AC

230 V

230 V

230 V

230 V

  • rated value

80 … 276 V

80 … 276 V

80 … 276 V

80 … 276 V

Type of voltage 2 of the supply voltage

DC

DC

DC

DC

Supply voltage for DC

220 V

220 V

220 V

220 V

  • rated value

46.25 … 300 V

46.25 … 300 V

46.25 … 300 V

46.25 … 300 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.08 A

0.08 A

0.08 A

0.08 A

Active power loss

  • at 24 V for DC

-

-

-

-

  • at 230 V AC

18 W

18 W

18 W

18 W

  • at 250 V with DC

18 W

18 W

18 W

18 W

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

Conformal coating

-

Conformal coating

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Compact

Compact

Width

60 mm

60 mm

60 mm

60 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

123 mm

123 mm

123 mm

123 mm

Net weight

1.85 kg

1.85 kg

2.12 kg

2.12 kg

Type of mounting

  • Installation 19 inch

Yes

Yes

Yes

Yes

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

No

No

No

No

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported

  • GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

Yes

Yes

Yes

Yes

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

Standard

  • for EMC

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

  • for EMC from FM

-

-

-

-

  • for hazardous zone

-

-

-

-

  • for safety of CSA and UL

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

  • for hazardous area of CSA and UL

-

-

-

-

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50124-1

No

No

No

No

  • IEC 61850-3

Yes

Yes

Yes

Yes

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

-

-

-

-

  • Bureau Veritas (BV)

-

-

-

-

  • Det Norske Veritas (DNV)

-

-

-

-

  • Germanische Lloyd (GL)

-

-

-

-

  • Lloyds Register of Shipping (LRS)

-

-

-

-

  • Nippon Kaiji Kyokai (NK)

-

-

-

-


Order No.

6GK5 307-2FD00-1EA3

6GK5 307-2FD00-1GA3

6GK5 307-2FD00-2EA3

6GK5 307-2FD00-2GA3

Product type designation

SCALANCE X307-2 EEC

SCALANCE X307-2 EEC

SCALANCE X307-2 EEC

SCALANCE X307-2 EEC

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

9

9

9

9

Number of electrical connections

  • for network components and terminal equipment

7

7

7

7

  • for operator console

-

-

-

-

  • for alarm contact

1

1

2

2

  • for media module

-

-

-

-

  • for power supply

1

1

2

2

  • for redundant power supply

1

1

2

2

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

  • for operator console

-

-

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

2 x 4-pole terminal block

2 x 4-pole terminal block

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

2

2

2

2

  • at 1000 Mbit/s

-

-

-

-

Design of optical interface for optical waveguide

  • at 100 Mbit/s

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

  • at 1000 Mbit/s

-

-

-

-

Connectable optical power relative to 1 mW

  • of the transmitter output

-19 … -14 dB

-19 … -14 dB

-19 … -14 dB

-19 … -14 dB

  • of the receiver input maximum

-14 dB

-14 dB

-14 dB

-14 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-32 dB

-32 dB

-32 dB

-32 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 … 5 km

0 … 5 km

0 … 5 km

0 … 5 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

Operating voltage of signaling contacts at AC rated value

-

-

-

-

Operating current of signaling contacts at AC maximum

-

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of supply voltage redundant power supply unit

No

No

Yes

Yes

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage at AC

-

-

-

-

  • rated value

- -

- -

- -

- -

Type of voltage 2 of the supply voltage

DC

DC

DC

DC

Supply voltage for DC

24 V

24 V

24 V

24 V

  • rated value

19.2 … 57.6 V

19.2 … 57.6 V

19.2 … 57.6 V

19.2 … 57.6 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.75 A

0.75 A

0.75 A

0.75 A

Active power loss

  • at 24 V for DC

12 W

12 W

12 W

12 W

  • at 230 V AC

-

-

-

-

  • at 250 V with DC

-

-

-

-

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

Conformal coating

-

Conformal coating

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Compact

Compact

Width

60 mm

60 mm

60 mm

60 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

123 mm

123 mm

123 mm

123 mm

Net weight

1.8 kg

1.8 kg

2.03 kg

2.03 kg

Type of mounting

  • Installation 19 inch

Yes

Yes

Yes

Yes

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

No

No

No

No

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

Yes

Yes

Yes

Yes

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

Standard

  • for EMC

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

  • for safety of CSA and UL

UL 508

UL 508

UL 508

UL 508

  • for hazardous area of CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50124-1

No

No

No

No

  • IEC 61850-3

Yes

Yes

Yes

Yes

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

-

-

-

-

  • Bureau Veritas (BV)

-

-

-

-

  • Det Norske Veritas (DNV)

-

-

-

-

  • Germanische Lloyd (GL)

-

-

-

-

  • Lloyds Register of Shipping (LRS)

-

-

-

-

  • Nippon Kaiji Kyokai (NK)

-

-

-

-


Order No.

6GK5 307-2FD00-3EA3

6GK5 307-2FD00-3GA3

6GK5 307-2FD00-4EA3

6GK5 307-2FD00-4GA3

Product type designation

SCALANCE X307-2 EEC

SCALANCE X307-2 EEC

SCALANCE X307-2 EEC

SCALANCE X307-2 EEC

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

9

9

9

9

Number of electrical connections

  • for network components and terminal equipment

7

7

7

7

  • for operator console

-

-

-

-

  • for alarm contact

1

1

2

2

  • for media module

-

-

-

-

  • for power supply

1

1

1

1

  • for redundant power supply

-

-

1

1

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

  • for operator console

-

-

-

-

  • for signaling contact

3-pole terminal block

3-pole terminal block

3-pole terminal block

3-pole terminal block

  • for power supply

3-pole terminal block

3-pole terminal block

2 x 3-pole terminal block

2 x 3-pole terminal block

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

2

2

2

2

  • at 1000 Mbit/s

-

-

-

-

Design of optical interface for optical waveguide

  • at 100 Mbit/s

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

  • at 1000 Mbit/s

-

-

-

-

Connectable optical power relative to 1 mW

  • of the transmitter output

-19 … -14 dB

-19 … -14 dB

-19 … -14 dB

-19 … -14 dB

  • of the receiver input maximum

-14 dB

-14 dB

-14 dB

-14 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-32 dB

-32 dB

-32 dB

-32 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 … 5 km

0 … 5 km

0 … 5 km

0 … 5 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

Operating voltage of signaling contacts at AC rated value

276 V

276 V

276 V

276 V

Operating current of signaling contacts at AC maximum

5 A

5 A

5 A

5 A

Operating voltage of signaling contacts at DC rated value

230 V

230 V

230 V

230 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of supply voltage redundant power supply unit

No

No

Yes

Yes

Type of voltage of supply voltage

AC

AC

AC

AC

Supply voltage at AC

230 V

230 V

230 V

230 V

  • rated value

80 … 276 V

80 … 276 V

80 … 276 V

80 … 276 V

Type of voltage 2 of the supply voltage

DC

DC

DC

DC

Supply voltage for DC

220 V

220 V

220 V

220 V

  • rated value

46.25 … 300 V

46.25 … 300 V

46.25 … 300 V

46.25 … 300 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.08 A

0.08 A

0.08 A

0.08 A

Active power loss

  • at 24 V for DC

-

-

-

-

  • at 230 V AC

18 W

18 W

18 W

18 W

  • at 250 V with DC

18 W

18 W

18 W

18 W

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

Conformal coating

-

Conformal coating

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Compact

Compact

Width

60 mm

60 mm

60 mm

60 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

123 mm

123 mm

123 mm

123 mm

Net weight

1.85 kg

1.85 kg

2.12 kg

2.12 kg

Type of mounting

  • Installation 19 inch

Yes

Yes

Yes

Yes

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

No

No

No

No

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

Yes

Yes

Yes

Yes

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

Standard

  • for EMC

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

  • for EMC from FM

-

-

-

-

  • for hazardous zone

-

-

-

-

  • for safety of CSA and UL

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

  • for hazardous area of CSA and UL

-

-

-

-

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50124-1

No

No

No

No

  • IEC 61850-3

Yes

Yes

Yes

Yes

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

-

-

-

-

  • Bureau Veritas (BV)

-

-

-

-

  • Det Norske Veritas (DNV)

-

-

-

-

  • Germanische Lloyd (GL)

-

-

-

-

  • Lloyds Register of Shipping (LRS)

-

-

-

-

  • Nippon Kaiji Kyokai (NK)

-

-

-

-
























































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET ECOFAST Введение Industrial Ethernet PROFINET Введение Привода Контроллеры Распределенная периферия Система управления перемещениями SIMOTION Системы ЧПУ SINUMERIK Устройства отображения и контроля Системы Человеко-Машинного Интерфейса Активные сетевые компоненты Промышленные ПК Производственные датчики Пассивные сетевые компоненты Сетевые компоненты для Industrial Ethernet Industrial Ethernet коммутаторы Компактные коммутаторы CSM Неуправляемые коммутаторы SCALANCE X-000 Неуправляемые коммутаторы/конверторы SCALANCE X-100 Управляемые коммутаторы SCALANCE X-200 Управляемые коммутаторы SCALANCE X-200IRT Управляемые коммутаторы SCALANCE X-300 SCALANCE X-300 managed Коммутаторы SIPLUS SCALANCE X-300 SCALANCE XR-300 managed SCALANCE X-300PoE managed SCALANCE XR-300PoE managed Управляемые коммутаторы SCALANCE X-300EEC Управляемые коммутаторы SCALANCE XR-300EEC Конвертирующие модули для SCALANCE X-300 Управляемые коммутаторы (Уровень 3) SCALANCE X-400 Безопасность передачи данных в промышленных сетях Промышленная мобильная коммуникация Маршрутизаторы Аппаратура управления Датчики Инжиниринговые пакеты Технологические компоненты PROFINET Системный интерфейс к SIMATIC HMI PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366
Яндекс.Метрика