Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru
SIPLUS SCALANCE X-300 managed

Order No.

6GK5 304-2BD00-2AA3

6GK5 306-1BF00-2AA3

6GK5 307-3BL00-2AA3

6GK5 307-3BM00-2AA3

Product type designation

SCALANCE X304-2FE

SCALANCE X306-1LD FE

SCALANCE X307-3

SCALANCE X307-3LD

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

-

-

1 000 Mbit/s

1 000 Mbit/s

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

6

7

10

10

Number of electrical connections

  • for network components and terminal equipment

4

6

7

7

  • for operator console

-

-

-

-

  • for alarm contact

1

1

1

1

  • for media module

-

-

-

-

  • for power supply

1

1

1

1

  • for redundant power supply

2

2

2

2

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

  • for operator console

-

-

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

2

1

-

-

  • at 1000 Mbit/s

-

-

3

3

Design of optical interface for optical waveguide

  • at 100 Mbit/s

SC port (multimode up to 5 km)

SC port (singlemode up to 26 km)

-

-

  • at 1000 Mbit/s

-

-

SC port (multimode up to 0.75 km)

SC port (singlemode up to 10 km)

Connectable optical power relative to 1 mW

  • of the transmitter output

-19 … -14 dB

-15 … -8 dB

-9.5 … -4 dB

-9.5 … -3 dB

  • of the receiver input maximum

-3 dB

-3 dB

-3 dB

-3 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-32 dB

-34 dB

-17 dB

-21 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 … 5 km

0 … 26 km

0 … 0.75 km

0 … 10 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

Operating voltage of signaling contacts at AC rated value

-

-

-

-

Operating current of signaling contacts at AC maximum

-

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0,1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of supply voltage redundant power supply unit

No

No

No

No

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage external

24 V

24 V

24 V

24 V

  • minimum

18 V

18 V

18 V

18 V

  • maximum

32 V

32 V

32 V

32 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.26 A

0.2 A

0.4 A

0.4 A

Active power loss

  • at 24 V for DC

6.2 W

4.8 W

9.6 W

9.6 W

  • at 230 V AC

-

-

-

-

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +60 °C

-40 … +60 °C

-10 … +60 °C

-40 … +60 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

-

-

-

-

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

-

-

-

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Compact

Compact

Width

60 mm

60 mm

120 mm

120 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

123 mm

123 mm

123 mm

123 mm

Net weight

0.7 kg

0.7 kg

1.4 kg

1.4 kg

Type of mounting

  • Installation 19 inch

No

No

No

No

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

-

-

-

-

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

No

No

No

No

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

Standard

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

-

-

-

-

  • Railway application in accordance with EN 50124-1

-

-

-

-

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

-

-

Yes

Yes

  • Bureau Veritas (BV)

-

-

Yes

Yes

  • Det Norske Veritas (DNV)

-

-

Yes

Yes

  • Germanische Lloyd (GL)

-

-

Yes

Yes

  • Lloyds Register of Shipping (LRS)

-

-

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

-

-

Yes

Yes


Order No.

6GK5 308-2FL00-2AA3

6GK5 308-2FM00-2AA3

6GK5 308-2FN00-2AA3

6GK5 308-2FP00-2AA3

Product type designation

SCALANCE X308-2

SCALANCE X308-2LD

SCALANCE X308-2LH

SCALANCE X308-2LH+

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

10

10

10

10

Number of electrical connections

  • for network components and terminal equipment

8

8

8

8

  • for operator console

-

-

-

-

  • for alarm contact

1

1

1

1

  • for media module

-

-

-

-

  • for power supply

1

1

1

1

  • for redundant power supply

2

2

2

2

Design of electrical connection

  • for network components and terminal equipment

RJ45 port (1 x 1GE, 7 x FE)

RJ45 port (1 x 1GE, 7 x FE)

RJ45 port (1 x 1GE, 7 x FE)

RJ45 port (1 x 1GE, 7 x FE)

  • for operator console

-

-

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

-

-

-

-

  • at 1000 Mbit/s

2

2

2

2

Design of optical interface for optical waveguide

  • at 100 Mbit/s

-

-

-

-

  • at 1000 Mbit/s

SC port (multimode up to 0.75 km)

SC port (singlemode up to 10 km)

SC port (singlemode up to 40 km)

SC port (singlemode up to 70 km)

Connectable optical power relative to 1 mW

  • of the transmitter output

-9.5 … -4 dB

-9.5 … -3 dB

-6 … +0 dB

0 … 5 dB

  • of the receiver input maximum

-3 dB

-3 dB

-3 dB

-3 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-17 dB

-21 dB

-23 dB

-23 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

3 dB

8 dB

Range at the optical interface depending on the optical fiber used

0 … 0.75 km

0 … 10 km

8 … 40 km

30 … 70 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

Operating voltage of signaling contacts at AC rated value

-

-

-

-

Operating current of signaling contacts at AC maximum

-

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of supply voltage redundant power supply unit

No

No

No

No

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage external

24 V

24 V

24 V

24 V

  • minimum

18 V

18 V

18 V

18 V

  • maximum

32 V

32 V

32 V

32 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.4 A

0.4 A

0.4 A

0.4 A

Active power loss

  • at 24 V for DC

9.6 W

9.6 W

9.6 W

9.6 W

  • at 230 V AC

-

-

-

-

Permitted ambient conditions

Ambient temperature

  • during operating

-10 … +60 °C

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

-

-

-

-

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

-

-

-

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Compact

Compact

Width

120 mm

120 mm

120 mm

120 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

123 mm

123 mm

123 mm

123 mm

Net weight

1.4 kg

1.4 kg

1.4 kg

1.4 kg

Type of mounting

  • Installation 19 inch

No

No

No

No

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

-

-

-

-

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

No

No

No

No

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

Standard

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

Verification of suitability

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

-

-

-

-

  • Railway application in accordance with EN 50124-1

-

-

-

-

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

Yes

Yes

  • Germanische Lloyd (GL)

Yes

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

Yes


Order No.

6GK5 310-0BA00-2AA3

6GK5 310-0FA00-2AA3

6GK5 320-1BD00-2AA3

6GK5 320-3BF00-2AA3

Product type designation

SCALANCE X310FE

SCALANCE X310

SCALANCE X320-1FE

SCALANCE X320-3LD FE

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 3

-

1 000 Mbit/s

-

-

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

10

10

21

23

Number of electrical connections

  • for network components and terminal equipment

10

10

20

20

  • for operator console

-

-

-

-

  • for alarm contact

1

1

1

1

  • for media module

-

-

-

-

  • for power supply

1

1

1

1

  • for redundant power supply

2

2

2

2

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

RJ45 port (3 x 1GE, 7 x FE)

RJ45 port

RJ45 port

  • for operator console

-

-

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

-

-

1

3

  • at 1000 Mbit/s

-

-

-

-

Design of optical interface for optical waveguide

  • at 100 Mbit/s

-

-

SC port (multimode up to 5 km)

SC port (1 x multimode up to 5 km, 2 x singlemode up to 26 km)

  • at 1000 Mbit/s

-

-

-

-

Connectable optical power relative to 1 mW

  • of the transmitter output

- -

- -

-19 … -14 dB

-15 … -8 dB

  • of the receiver input maximum

-

-

-3 dB

-3 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-

-

-32 dB

-34 dB

Attenuation of fiber-optic cable transmission link minimum necessary

-

-

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

- -

- -

0 … 5 km

0 … 26 km

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Inputs/outputs

Operating voltage of signaling contacts at AC rated value

-

-

-

-

Operating current of signaling contacts at AC maximum

-

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of supply voltage redundant power supply unit

No

No

No

No

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage external

24 V

24 V

24 V

24 V

  • minimum

18 V

18 V

18 V

18 V

  • maximum

32 V

32 V

32 V

32 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.4 A

0.4 A

0.4 A

0.5 A

Active power loss

  • at 24 V for DC

9.6 W

9.6 W

9.6 W

12 W

  • at 230 V AC

-

-

-

-

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

-40 … +60 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • Comment

-

-

-

-

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Ambient condition for (standard) operation mode

-

-

-

-

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Compact

Compact

Width

120 mm

120 mm

180 mm

180 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

123 mm

123 mm

123 mm

123 mm

Net weight

1.4 kg

1.4 kg

1.65 kg

1.65 kg

Type of mounting

  • Installation 19 inch

No

No

No

No

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • for IRT PROFINET IO switch

-

-

-

-

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

Yes

  • Redundancy manager

Yes

Yes

Yes

Yes

  • Standby redundancy

Yes

Yes

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

  • NTP

No

No

No

No

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

No

No

No

No

  • IEEE 1588 profile gPTP

-

-

-

-

  • IEEE 1588 profile PSRC

-

-

-

-

Type of time synchronization

-

-

-

-

Standards, specifications, approvals

Standard

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

-

-

-

-

  • Railway application in accordance with EN 50124-1

-

-

-

-

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

-

-

  • Bureau Veritas (BV)

Yes

Yes

-

-

  • Det Norske Veritas (DNV)

Yes

Yes

-

-

  • Germanische Lloyd (GL)

Yes

Yes

-

-

  • Lloyds Register of Shipping (LRS)

Yes

Yes

-

-

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

-

-


Order No.

6GK5 308-2GG00-2AA2

6GK5 308-2GG00-2CA2

Product type designation

SCALANCE X308-2M

SCALANCE X308-2M TS

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

Transfer rate 3

1 000 Mbit/s

1 000 Mbit/s

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

8

8

Number of electrical connections

  • for network components and terminal equipment

4

4

  • for operator console

-

-

  • for alarm contact

1

1

  • for media module

2

2

  • for power supply

1

1

  • for redundant power supply

1

1

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

RJ45 port

  • for operator console

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

-

-

  • at 1000 Mbit/s

-

-

Design of optical interface for optical waveguide

  • at 100 Mbit/s

Dependent on selected media modules

Dependent on selected media modules

  • at 1000 Mbit/s

Dependent on selected media modules

Dependent on selected media modules

Connectable optical power relative to 1 mW

  • of the transmitter output

- -

- -

  • of the receiver input maximum

-

-

Optical sensitivity relative to 1 mW of the receiver input minimum

-

-

Attenuation of fiber-optic cable transmission link minimum necessary

-

-

Range at the optical interface depending on the optical fiber used

- -

- -

design of the removable storage C-PLUG

Yes

Yes

Inputs/outputs

Operating voltage of signaling contacts at AC rated value

-

-

Operating current of signaling contacts at AC maximum

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of supply voltage redundant power supply unit

No

No

Type of voltage of supply voltage

DC

DC

Supply voltage external

24 V

12 V

  • minimum

18 V

20 V

  • maximum

32 V

30 V

Product component fusing at power supply input

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.7 A

0.7 A

Active power loss

  • at 24 V for DC

16.6 W

16.6 W

  • at 230 V AC

-

-

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

  • Comment

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Reduced operating temperature through the use of media modules (-40 °C to +70 °C) or SFP plug-in transceivers (-40 °C to +60 °C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 °C.

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

Ambient condition for (standard) operation mode

-

-

Protection class IP

IP20

IP20

Design, dimensions and weight

Design

Compact

Compact

Width

120 mm

120 mm

Height

125 mm

125 mm

Depth

124 mm

124 mm

Net weight

1.4 kg

1.4 kg

Type of mounting

  • Installation 19 inch

No

No

  • 35 mm DIN rail mounting

Yes

Yes

  • wall mounting

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Type of mounting

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

  • web-based management

Yes

Yes

  • MIB support

Yes

Yes

  • TRAPs via email

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

  • RMON

Yes

Yes

  • SMTP server

Yes

Yes

  • Port mirroring

Yes

Yes

  • CoS

Yes

Yes

  • for IRT PROFINET IO switch

-

-

  • PROFINET IO diagnosis

Yes

Yes

  • switch-managed

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

  • HTTP

Yes

Yes

  • HTTPS

Yes

Yes

  • TFTP

Yes

Yes

  • FTP

Yes

Yes

  • BOOTP

Yes

Yes

  • SNMP v1

Yes

Yes

  • SNMP v2

Yes

Yes

  • SNMP v3

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

  • GMRP

Yes

Yes

  • DCP

Yes

Yes

  • LLDP

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

  • Statistics Packet Size

Yes

Yes

  • Statistics packet type

Yes

Yes

  • Error statistics

Yes

Yes

  • SysLog

Yes

Yes

Product functionsVLAN

Product function

  • VLAN - port based

Yes

Yes

  • VLAN dynamic

Yes

Yes

Number of VLANs maximum

255

255

Number of VLANs - dynamic maximum

255

255

Protocol is supported GVRP

Yes

Yes

Product functionsDHCP

Product function

  • DHCP client

Yes

Yes

  • DHCP Option 82

Yes

Yes

  • DHCP Option 66

Yes

Yes

  • DHCP Option 67

Yes

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

  • Redundancy manager

Yes

Yes

  • Standby redundancy

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

  • redundancy procedure STP

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

  • Passive listening

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

  • STP

Yes

Yes

  • RSTP

Yes

Yes

  • RSTP big network support

Yes

Yes

  • LACP

Yes

Yes

Product functionsSecurity

Product function

  • ACL - port/MAC-based

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

  • broadcast blocking

Yes

Yes

Protocol is supported SSH

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Protocol is supported

  • NTP

No

No

  • SNTP

Yes

Yes

  • IEEE 1588 profile default

Yes

Yes

  • IEEE 1588 profile gPTP

-

-

  • IEEE 1588 profile PSRC

-

-

Type of time synchronization

-

-

Standards, specifications, approvals

Standard

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2

Verification of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2, EN 61000-6-4

  • CE mark

Yes

Yes

  • C-Tick

Yes

Yes

  • Railway application in accordance with EN 50155

-

Yes

  • Railway application in accordance with EN 50124-1

-

-

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

-

-

  • Bureau Veritas (BV)

-

-

  • Det Norske Veritas (DNV)

-

-

  • Germanische Lloyd (GL)

-

-

  • Lloyds Register of Shipping (LRS)

-

-

  • Nippon Kaiji Kyokai (NK)

-

-
























































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET ECOFAST Введение Industrial Ethernet PROFINET Введение Привода Контроллеры Распределенная периферия Система управления перемещениями SIMOTION Системы ЧПУ SINUMERIK Устройства отображения и контроля Системы Человеко-Машинного Интерфейса Активные сетевые компоненты Промышленные ПК Производственные датчики Пассивные сетевые компоненты Сетевые компоненты для Industrial Ethernet Industrial Ethernet коммутаторы Компактные коммутаторы CSM Неуправляемые коммутаторы SCALANCE X-000 Неуправляемые коммутаторы/конверторы SCALANCE X-100 Управляемые коммутаторы SCALANCE X-200 Управляемые коммутаторы SCALANCE X-200IRT Управляемые коммутаторы SCALANCE X-300 SCALANCE X-300 managed Коммутаторы SIPLUS SCALANCE X-300 SCALANCE XR-300 managed SCALANCE X-300PoE managed SCALANCE XR-300PoE managed Управляемые коммутаторы SCALANCE X-300EEC Управляемые коммутаторы SCALANCE XR-300EEC Конвертирующие модули для SCALANCE X-300 Управляемые коммутаторы (Уровень 3) SCALANCE X-400 Безопасность передачи данных в промышленных сетях Промышленная мобильная коммуникация Маршрутизаторы Аппаратура управления Датчики Инжиниринговые пакеты Технологические компоненты PROFINET Системный интерфейс к SIMATIC HMI PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366