Order No. |
6GK5 200-4AH00-2BA3 |
6GK5 201-3BH00-2BA3 |
6GK5 202-2BH00-2BA3 |
Product type designation |
SCALANCE X200-4P IRT |
SCALANCE X201-3P IRT |
SCALANCE X202-2P IRT |
Transmission rate |
|||
Transfer rate 1 |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
Interfaces |
|||
Number of electrical/optical connections |
|||
|
4 |
4 |
4 |
|
- |
- |
- |
Number of electrical connections |
|||
|
- |
1 |
2 |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
Design of electrical/optical connections for network components or terminal equipment |
|||
Design of electrical connection |
|||
|
- |
RJ45 port |
RJ45 port |
|
2-pole terminal block |
2-pole terminal block |
2-pole terminal block |
|
4-pole terminal block |
4-pole terminal block |
4-pole terminal block |
Number of optical interfaces for optical waveguide at 100 Mbit/s |
4 |
3 |
2 |
Design of optical interface for optical waveguide at 100 Mbit/s |
SC-RJ/POF port |
SC-RJ/POF port |
SC-RJ/POF port |
Connectable optical power relative to 1 mW |
|||
|
-8 ... -2 dB |
-8 ... -2 dB |
-8 ... -2 dB |
|
- |
- |
- |
Optical sensitivity relative to 1 mW of the receiver input minimum |
-25 dB |
-25 dB |
-25 dB |
Attenuation of fiber-optic cable transmission link minimum necessary |
0 dB |
0 dB |
0 dB |
Range at the optical interface depending on the optical fiber used |
0 … 0.05 km |
0 … 0.05 km |
0 … 0.05 km |
design of the removable storage C-PLUG |
Yes |
Yes |
Yes |
Inputs/outputs |
|||
Operating current of signaling contacts at AC maximum |
- |
- |
- |
Operating voltage of signaling contacts at DC rated value |
24 V |
24 V |
24 V |
Operating current of signaling contacts at DC maximum |
0.1 A |
0.1 A |
0.1 A |
Supply voltage, current consumption, power loss |
|||
Type of voltage of supply voltage |
DC |
DC |
DC |
Supply voltage external |
24 V |
24 V |
24 V |
|
18 V |
18 V |
18 V |
|
32 V |
32 V |
32 V |
Product component fusing at power supply input |
Yes |
Yes |
Yes |
Type of fusing at input for supply voltage |
|||
Consumed current maximum |
0.4 A |
0.35 A |
0.3 A |
Active power loss at 24 V for DC |
9.6 W |
8.4 W |
7.2 W |
Permitted ambient conditions |
|||
Ambient temperature |
|||
|
-25 … +40 °C |
-25 … +50 °C |
-25 … +60 °C |
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
- |
- |
- |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
95 % |
Protection class IP |
IP30 |
IP30 |
IP30 |
Design, dimensions and weight |
|||
Design |
Compact |
Compact |
Compact |
Width |
60 mm |
60 mm |
60 mm |
Height |
125 mm |
125 mm |
125 mm |
Depth |
124 mm |
124 mm |
124 mm |
Net weight |
0.78 kg |
0.78 kg |
0.78 kg |
Type of mounting |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
Product properties, functions, componentsgeneral |
|||
Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s |
50 |
50 |
50 |
Cascading in cases of star structuring |
Any (depending only on signal propagation time) |
Any (depending only on signal propagation time) |
Any (depending only on signal propagation time) |
Product functionsmanagement, configuration |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
No |
No |
No |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Protocol is supported |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
No |
No |
No |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Identification & maintenance |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsDiagnosis |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsDHCP |
|||
Product function DHCP client |
Yes |
Yes |
Yes |
Product functionsRedundancy |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
- |
- |
- |
|
Yes |
Yes |
Yes |
Protocol is supported PRP |
- |
- |
- |
Product functionsSecurity |
|||
Protocol is supported SSH |
Yes |
Yes |
Yes |
Product functionsTime |
|||
Product function SICLOCK support |
Yes |
Yes |
Yes |
Protocol is supported |
|||
|
No |
No |
No |
|
Yes |
Yes |
Yes |
Standards, specifications, approvals |
|||
Standard |
|||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 |
|
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 |
ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 |
ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 |
|
EN 61000-6-4:2001 |
EN 61000-6-4 (Class A) |
EN 61000-6-4:2001 (Class A) |
|
EN 61000-6-2:2001 |
EN 61000-6-2 |
EN 61000-6-4:2001 |
Verification of suitability |
EN 61000-6-2:2001, EN 61000-6-4:2001 |
EN 61000-6-2, EN 61000-6-4 |
EN 61000-6-4:2001 |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
No |
No |
No |
|
No |
No |
No |
Marine classification association |
|||
|
No |
No |
No |
|
No |
No |
No |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
No |
No |
Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) |
No |
No |
No |
Order No. |
6GK5 202-2BB00-2BA3 |
6GK5 204-0BA00-2BA3 |
Product type designation |
SCALANCE X202-2IRT |
SCALANCE X204IRT |
Transmission rate |
||
Transfer rate 1 |
10 Mbit/s |
10 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
100 Mbit/s |
Interfaces |
||
Number of electrical/optical connections |
||
|
4 |
4 |
|
- |
- |
Number of electrical connections |
||
|
2 |
4 |
|
1 |
1 |
|
1 |
1 |
|
1 |
1 |
Design of electrical/optical connections for network components or terminal equipment |
||
Design of electrical connection |
||
|
RJ45 port |
RJ45 port |
|
2-pole terminal block |
2-pole terminal block |
|
4-pole terminal block |
4-pole terminal block |
Number of optical interfaces for optical waveguide at 100 Mbit/s |
2 |
- |
Design of optical interface for optical waveguide at 100 Mbit/s |
BFOC sockets (multimode up to 5 km) |
- |
Connectable optical power relative to 1 mW |
||
|
-19 ... -14 dB |
- - |
|
- |
- |
Optical sensitivity relative to 1 mW of the receiver input minimum |
-34 dB |
- |
Attenuation of fiber-optic cable transmission link minimum necessary |
0 dB |
- |
Range at the optical interface depending on the optical fiber used |
0 … 0.05 km |
- - |
design of the removable storage C-PLUG |
Yes |
Yes |
Inputs/outputs |
||
Operating current of signaling contacts at AC maximum |
- |
- |
Operating voltage of signaling contacts at DC rated value |
24 V |
24 V |
Operating current of signaling contacts at DC maximum |
0.1 A |
0.1 A |
Supply voltage, current consumption, power loss |
||
Type of voltage of supply voltage |
DC |
DC |
Supply voltage external |
24 V |
24 V |
|
18 V |
18 V |
|
32 V |
32 V |
Product component fusing at power supply input |
Yes |
Yes |
Type of fusing at input for supply voltage |
||
Consumed current maximum |
0.3 A |
0.2 A |
Active power loss at 24 V for DC |
6 W |
4.8 W |
Permitted ambient conditions |
||
Ambient temperature |
||
|
-40 … +60 °C |
-40 … +70 °C |
|
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +70 °C |
-40 … +70 °C |
|
- |
- |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
Protection class IP |
IP30 |
IP30 |
Design, dimensions and weight |
||
Design |
Compact |
Compact |
Width |
60 mm |
60 mm |
Height |
125 mm |
125 mm |
Depth |
124 mm |
124 mm |
Net weight |
0.78 kg |
0.78 kg |
Type of mounting |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Type of mounting |
- |
- |
Product properties, functions, componentsgeneral |
||
Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s |
50 |
50 |
Cascading in cases of star structuring |
Any (depending only on signal propagation time) |
Any (depending only on signal propagation time) |
Product functionsmanagement, configuration |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
No |
No |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Protocol is supported |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
No |
No |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Identification & maintenance |
||
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsDiagnosis |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsDHCP |
||
Product function DHCP client |
Yes |
Yes |
Product functionsRedundancy |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
- |
- |
|
Yes |
Yes |
Protocol is supported PRP |
- |
- |
Product functionsSecurity |
||
Protocol is supported SSH |
Yes |
Yes |
Product functionsTime |
||
Product function SICLOCK support |
Yes |
Yes |
Protocol is supported |
||
|
No |
No |
|
Yes |
Yes |
Standards, specifications, approvals |
||
Standard |
||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 |
|
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 |
ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 |
|
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
|
EN 61000-6-4:2001 |
EN 61000-6-4:2001 |
Verification of suitability |
EN 61000-6-4:2001 |
EN 61000-6-4:2001 |
|
Yes |
Yes |
|
Yes |
Yes |
|
No |
No |
|
No |
No |
Marine classification association |
||
|
Yes |
Yes |
|
No |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Marine classification association/ Polski Rejestr Statkow (PRS) |
No |
No |
Order No. |
6GK5 204-0JA00-2BA6 |
6GK5 202-2JR00-2BA6 |
6GK5 201-3JR00-2BA6 |
Product type designation |
SCALANCE X204 IRT PRO |
SCALANCE X202-2P IRT PRO |
SCALANCE X201-3P IRT PRO |
Transmission rate |
|||
Transfer rate 1 |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
Transfer rate 2 |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
Interfaces |
|||
Number of electrical/optical connections |
|||
|
4 |
4 |
4 |
|
- |
- |
- |
Number of electrical connections |
|||
|
4 |
2 |
1 |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
|
- |
- |
- |
Design of electrical/optical connections for network components or terminal equipment |
|||
Design of electrical connection |
|||
|
RJ45 push-pull plug PRO |
RJ45 push-pull plug PRO |
RJ45 push-pull plug PRO |
|
5 pin M12 socket |
5 pin M12 socket |
5 pin M12 socket |
|
5-pin push-pull plug PRO socket |
5-pin push-pull plug PRO socket |
5-pin push-pull plug PRO socket |
Number of optical interfaces for optical waveguide at 100 Mbit/s |
- |
2 |
3 |
Design of optical interface for optical waveguide at 100 Mbit/s |
- |
SC-RJ/POF push-pull plug PRO port |
SC-RJ/POF push-pull plug PRO port |
Connectable optical power relative to 1 mW |
|||
|
- - |
-8 … -2 dB |
-8 … -2 dB |
|
- |
- |
- |
Optical sensitivity relative to 1 mW of the receiver input minimum |
- |
-25 dB |
-25 dB |
Attenuation of fiber-optic cable transmission link minimum necessary |
- |
0 dB |
0 dB |
Range at the optical interface |
|||
|
- - |
0 … 0.05 km |
0 … 0.05 km |
design of the removable storage C-PLUG |
Yes |
Yes |
Yes |
Inputs/outputs |
|||
Operating current of signaling contacts at AC maximum |
- |
- |
- |
Operating voltage of signaling contacts at DC rated value |
24 V |
24 V |
24 V |
Operating current of signaling contacts at DC maximum |
0.1 A |
0.1 A |
0.1 A |
Supply voltage, current consumption, power loss |
|||
Type of voltage of supply voltage |
DC |
DC |
DC |
Supply voltage external |
24 V |
24 V |
24 V |
|
18 V |
18 V |
18 V |
|
32 V |
32 V |
32 V |
Product component fusing at power supply input |
Yes |
Yes |
Yes |
Type of fusing at input for supply voltage |
|||
Consumed current maximum |
0.2 A |
0.3 A |
0.33 A |
Active power loss at 24 V for DC |
4.8 W |
7.2 W |
7.92 W |
Permitted ambient conditions |
|||
Ambient temperature |
|||
|
-25 … +70 °C |
-25 … +60 °C |
-25 … +60 °C |
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
- |
- |
- |
Relative humidity at 25 °C without condensation during operating maximum |
95 % |
95 % |
95 % |
Protection class IP |
IP67 |
IP67 |
IP67 |
Design, dimensions and weight |
|||
Design |
Compact |
Compact |
Compact |
Width |
90 mm |
90 mm |
90 mm |
Height |
125 mm |
125 mm |
125 mm |
Depth |
124 mm |
124 mm |
124 mm |
net weight |
1 kg |
1 kg |
1 kg |
Type of mounting |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
Product properties, functions, componentsgeneral |
|||
Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s |
50 |
50 |
50 |
Cascading in cases of star structuring |
Any (depending only on signal propagation time) |
Any (depending only on signal propagation time) |
Any (depending only on signal propagation time) |
Product functionsmanagement, configuration |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
No |
No |
No |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Protocol is supported |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
No |
No |
No |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Identification & Maintenance |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsDiagnosis |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsDHCP |
|||
Product function DHCP client |
Yes |
Yes |
Yes |
Product functionsRedundancy |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
- |
- |
- |
|
Yes |
Yes |
Yes |
Protocol is supported PRP |
- |
- |
- |
Product functionsSecurity |
|||
Protocol is supported SSH |
Yes |
Yes |
Yes |
Product functionsTime |
|||
Product function SICLOCK support |
Yes |
Yes |
Yes |
Protocol is supported |
|||
|
No |
No |
No |
|
Yes |
Yes |
Yes |
Standards, specifications, approvals |
|||
Standard |
|||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4 |
|
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 |
ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 |
ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 |
|
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
EN 61000-6-4:2001 (Class A) |
|
EN 61000-6-4:2001 |
EN 61000-6-4:2001 |
EN 61000-6-4:2001 |
Verification of suitability |
EN 61000-6-4:2001 |
EN 61000-6-4:2001 |
EN 61000-6-4:2001 |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
No |
No |
No |
|
No |
No |
No |
Marine classification association |
|||
|
No |
No |
No |
|
Yes |
No |
No |
|
Yes |
Yes |
No |
|
Yes |
Yes |
No |
|
Yes |
Yes |
No |
|
Yes |
Yes |
No |
Marine classification association/ Polski Rejestr Statkow (PRS) |
No |
No |
No |