|
Order No. |
6GK1 571-1AA00 |
6GK1 571-1AM00 |
|
Product type designation |
CP 5711 |
CP 5711 MPI |
|
Transmission rate |
||
|
Transmission rate at interface 1 in accordance with PROFIBUS |
9.6 Kbit/s to 12 Mbit/s |
9.6 Kbit/s to 12 Mbit/s |
|
Interfaces |
||
|
Number of electrical connections at interface 1 in accordance with PROFIBUS |
1 |
1 |
|
Number of interfaces in accordance with USB |
1 |
1 |
|
Number of electrical connections for power supply |
1 |
1 |
|
Design of electrical connection |
||
|
9-pin D-sub socket (RS 485) |
9-pin D-sub socket (RS 485) |
|
2-pin terminal block |
2-pin terminal block |
|
Standard B socket with mechanical locking |
Standard B socket with mechanical locking |
|
Standard for USB 2.0 ports |
Yes |
Yes |
|
Supply voltage, current consumption, power loss |
||
|
Type of power supply |
DC |
DC |
|
Type of power supply: optional external supply |
Yes |
Yes |
|
Power supply |
||
|
5 V |
5 V |
|
24 V |
24 V |
|
18 V |
18 V |
|
30 V |
30 V |
|
Power supply directly from USB if provided sufficiently by PC / external supply possible as alternative |
Power supply directly from USB if provided sufficiently by PC / external supply possible as alternative |
|
Relative symmetrical tolerance |
||
|
5 % |
5 % |
|
5 % |
5 % |
|
Current consumed |
||
|
0.5 A |
0.5 A |
|
0.3 A |
0.3 A |
|
Effective power loss |
2.5 W |
2.5 W |
|
Permitted ambient conditions |
||
|
Ambient temperature |
||
|
0 … 60 °C |
5 … 60 °C |
|
-40 … +60 °C |
-20 … +60 °C |
|
-40 … +60 °C |
-20 … +60 °C |
|
Relative humidity at 25 °C without condensation during operation, maximum |
85 % |
85 % |
|
IP degree of protection |
IP20 |
IP20 |
|
Design, dimensions and weights |
||
|
Module format |
USB V2.0 adapter |
USB V2.0 adapter |
|
Width |
85 mm |
85 mm |
|
Height |
137 mm |
137 mm |
|
Depth |
35 mm |
35 mm |
|
Net weight |
300 g |
500 g |
|
Type of mounting: 35 mm DIN rail mounting |
Yes |
Yes |
|
Type of mounting |
Mounting on DIN rail with optional rail support |
Mounting on DIN rail with optional rail support |
|
Product properties, functions, componentsGeneral |
||
|
Number of plug-in cards of same design which can be inserted per PC station |
1 |
1 |
|
Number of modules - Note |
- |
- |
|
Performance data |
||
|
Performance dataOpen communication |
||
|
Software required for open communication by means of SEND/RECEIVE |
Yes, SOFTNET-PB DP / SOFTNET-PB DP slave / SOFTNET-PB S7 |
Yes, SOFTNET-PB DP / SOFTNET-PB DP slave / SOFTNET-PB S7 |
|
Number of possible connections for open communication by means of SEND/RECEIVE, maximum |
50 |
50 |
|
Performance data PROFIBUS DP |
||
|
Software required for DP master function |
Yes, SOFTNET-PB DP |
Yes, SOFTNET-PB DP |
|
Service as DP master |
||
|
Yes |
Yes |
|
No |
No |
|
No |
No |
|
Number of DP slaves operable on DP master |
64 |
64 |
|
Data volume |
||
|
15 616 bytes |
15 616 bytes |
|
15 616 bytes |
15 616 bytes |
|
244 bytes |
244 bytes |
|
244 bytes |
244 bytes |
|
244 bytes |
244 bytes |
|
Software required for DP slave function |
Yes, SOFTNET-PB DP Slave |
Yes, SOFTNET-PB DP Slave |
|
Service as DP slave |
||
|
Yes |
Yes |
|
No |
No |
|
Data volume |
||
|
122 bytes |
122 bytes |
|
122 bytes |
122 bytes |
|
Performance dataS7 communication |
||
|
Software required for S7 communication |
Yes, SOFTNET-PB S7 |
Yes, SOFTNET-PB S7 |
|
Number of possible connections for S7/PG communication, maximum |
8 |
8 |
|
Performance dataMultiprotocol operation |
||
|
Number of configurable connections per PC station |
207 |
207 |
|
Product functionsManagement, configuration, programming |
||
|
Configuration software required |
NCM PC included in scope of delivery of required software product |
NCM PC included in scope of delivery of required software product |
|
Product functionsDiagnostics |
||
|
Product function: Port diagnostics |
Yes |
Yes |
|
Standards, specifications, approvals |
||
|
Standard |
||
|
2004/108/EC |
2004/108/EC |
|
CAN/CSA C22.2 & UL 60950-1 |
CAN/CSA C22.2 & UL 60950-1 |
|
EN 61000-6-3, EN 61000-6-4 |
EN 61000-6-3, EN 61000-6-4 |
|
EN 61000-6-1, EN 61000-6-2 |
EN 61000-6-1, EN 61000-6-2 |
|
Certificate of suitability |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Accessories |
||
|
Accessories |
Optional: MPI cable, rail support |
Included in scope of delivery: MPI cable / optional: rail support |


