Order No. |
6EP1 332-2BA00 |
Technical specifications |
|
Product |
SITOP power |
Power supply, type |
24 V/3.7 A |
Input |
|
Input |
1-phase AC |
Supply voltage |
|
|
120 V |
|
230 V |
|
Set via wire jumper |
Input voltage |
|
|
93 … 132 V |
|
187 … 264 V |
Overvoltage resistance |
2.3 Vin rated, 1.3 ms |
Mains buffering at Iout rated, min. |
10 ms |
Mains buffering |
at Vin = 93/187 V |
Rated line frequency |
|
|
50 Hz |
|
60 Hz |
Rated line range |
47 … 63 Hz |
Input current |
|
|
1.8 A |
|
0.7 A |
Switch-on current limiting (+25 °C), max. |
32 A |
Duration of current limiting at 25 °C typical |
3 ms |
I t, max. |
0.8 A ·s |
Built-in incoming fuse |
T 3,15 A/250 V (not accessible) |
Protection in the mains power input (IEC 898) |
Recommended miniature circuit breaker: from 6 A, characteristic C |
Output |
|
Output |
controlled, isolated DC voltage |
Rated voltage Vout DC |
24 V |
Total tolerance, static ± |
3 % |
Static mains compensation, approx. |
0.1 % |
Static load balancing, approx. |
0.2 % |
Residual ripple peak-peak, max. |
0.15 V |
Spikes peak-peak, max. (bandwidth: 20 MHz) |
0.24 V |
Adjustment range |
22.8 … 26.4 V |
Product feature output voltage adjustable |
Yes |
Output voltage setting |
via potentiometer |
Note |
only permissible at ambient temperatur 0 °C to +50 °C |
Status display |
Green LED for 24 V OK |
On/off behavior |
No overshoot of Vout (soft start) |
Startup delay, max. |
3 s |
Voltage rise, typ. |
80 ms |
Rated current value Iout rated |
3.7 A |
Current range |
0 … 3.7 A |
delivered active power typ. |
90 W |
Parallel switching for enhanced performance |
Yes |
Note |
only permissable at ambient temperature 0 °C to 50 °C |
Numbers of parallel switchable units for enhanced performance |
2 |
Efficiency |
|
Efficiency at Vout rated, Iout rated, approx. |
80 % |
Power loss at Vout rated, Iout rated, approx. |
22 W |
Closed-loop control |
|
Dynamic mains compensation (Vin rated ±15 %), max. |
0.3 % |
Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ. |
2.5 % |
Load step setting time 50 to 100%, typ. |
0.2 ms |
Load step setting time 100 to 50%, typ. |
0.2 ms |
Protection and monitoring |
|
Output overvoltage protection |
Yes, according to EN 60950 |
Current limitation |
3.8 … 4.1 A |
Characteristic feature of the output short-circuit protected |
Yes |
Short-circuit protection |
Electronic shutdown, automatic restart |
Overload/short-circuit indicator |
- |
Safety |
|
Primary/secondary isolation |
Yes |
Potential separation |
Safety extra low output voltage Vout according to EN 60950-1 |
Protection class |
Class I |
stray current |
|
|
3.5 mA |
|
0.4 mA |
CE mark |
Yes |
UL/CSA approval |
Yes |
UL/cUL (CSA) approval |
cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289; cURus-Recognized (UL 1950, CSA C22.2 No. 60950), File 151273; UL 1310 |
Explosion protection |
- |
FM approval |
No |
FM approval |
- |
CB approval |
No |
Marine approval |
- |
Degree of protection (EN 60529) |
IP20 |
EMC |
|
Emitted interference |
EN 55022 Class B |
Supply harmonics limitation |
EN 61000-3-2 |
Noise immunity |
EN 61000-6-2 |
Operating data |
|
Ambient temperature |
|
|
0 … 60 °C |
|
with natural convection |
Ambient temparature |
|
|
-40 … +85 °C |
Ambient temparature |
|
|
-40 … +85 °C |
Humidity class according to EN 60721 |
Climate class 3K3, no condensation |
Mechanics |
|
Connection technology |
screw-type terminals |
Connections |
|
|
L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm single-core/finely stranded |
|
L+: 1 screw terminal for 0.5 ... 2.5 mm ; M: 2 screw terminals for 0.5 ... 2.5 mm |
|
- |
Width of the housing |
75 mm |
Height of the housing |
125 mm |
Depth of the housing |
125 mm |
Installation width |
75 mm |
Installation height |
225 mm |
Weight, approx. |
0.75 kg |
Product feature of the housing housing for side-by-side mounting |
Yes |
Type of mounting wall mounting |
No |
Type of fixing cap rail mounting |
Yes |
Type of mounting S7-300 rail mounting |
No |
Installation |
Snaps onto DIN rail EN 60715 35x7.5/15 |