Bestell-Nr. |
6GK1 411-6CA40-0AA0 |
6GK1 411-6CA40-0BA0 |
Product type designation |
IE/WSN-PA LINK |
IE/WSN-PA LINK |
Data transmission rate |
||
|
10 … 100 Mbit/s |
10 … 100 Mbit/s |
|
10 … 100 Mbit/s |
10 … 100 Mbit/s |
|
9.6 to 57.6 kbps |
9.6 to 57.6 kbps |
Interfaces |
||
Number of electrical connections |
||
|
1 |
1 |
|
1 |
1 |
|
1 |
1 |
|
1 |
1 |
Design of electrical connection |
||
|
RJ 45 port |
RJ 45 port |
|
RJ 45 port |
RJ 45 port |
|
2-pin terminal strip |
2-pin terminal strip |
|
3-pin terminal strip |
3-pin terminal strip |
InterfacesWireless |
||
Number of radio cards permanently installed |
1 |
1 |
Number of internal antennas |
1 |
0 |
Number of electrical connections for external antenna(s) |
0 |
1 |
Design of electrical connection for external antenna(s) |
- |
N-Connector |
Supply voltage, current consumption, power loss |
||
Type of power supply |
DC |
DC |
Supply voltage, external |
24 V |
24 V |
|
20 V |
20 V |
|
28 V |
28 V |
Current consumed from external power supply at 24 V DC, maximum |
0.5 A |
0.5 A |
Effective power loss, maximum |
12 W |
12 W |
Permitted ambient conditions |
||
Ambient temperature |
||
|
-40 … +60 °C |
-40 … +60 °C |
|
-40 … +85 °C |
-40 … +85 °C |
|
-40 … +85 °C |
-40 … +85 °C |
Relative humidity at 25 °C without condensation during operating phase, maximum |
90 % |
90 % |
IP degree of protection |
IP 65 |
IP 65 |
Design, dimensions and weights |
||
Housing width |
229 mm |
229 mm |
Housing height |
||
|
306 mm |
306 mm |
|
354 mm |
354 mm |
Housing depth |
89 mm |
89 mm |
Net weight |
4.54 kg |
4.54 kg |
Type of mounting |
||
|
Yes |
Yes |
|
Yes |
Yes |
Type of mounting |
Material for mast mounting included in scope of delivery |
Material for mast mounting included in scope of delivery |
Radio frequencies |
||
Radio frequency with WirelessHART in the 2.4 GHz frequency band |
||
|
2.4 GHz |
2.4 GHz |
|
2.5 GHz |
2.5 GHz |
Performance dataWirelessHART |
||
Number of WirelessHART devices which can be operated |
100 |
100 |
Network latency |
||
|
10 s |
10 s |
|
5 s |
5 s |
Transition link between two devices with WirelessHART network |
||
|
100 m |
100 m |
|
The values may deviate if obstacles affecting radio transmission are present |
The values may deviate if obstacles affecting radio transmission are present |
HART protocol is supported |
Yes |
Yes |
Product properties, functions, componentsGeneral |
||
Protocol is supported |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsManagement, configuration, programming |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsDiagnostics |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
Product functionsSecurity |
||
Product function |
||
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
|
Yes |
Yes |
SSL protocol is supported |
Yes |
Yes |
Encryption principle |
AES 128 bit |
AES 128 bit |
Product functionsTime |
||
NTP protocol is supported |
Yes |
Yes |
Standards, specifications, approvals |
||
Standard for WirelessHART |
HART V 7.1 |
HART V 7.1 |
Standard for wireless communication IEEE 802.15.4 |
Yes |
Yes |
Certificate of suitability |
||
|
Yes |
Yes |
|
CSA Division 2 & Dust Ignition-proof for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II, Groups E, F, and G / Suitable for Class III Hazardous Locations. / Install per Siemens drawing A5E02467236A. Temperature Code: T4 (-40°C < Ta < 60°C) CSA Enclosure Type 4X |
CSA Division 2 & Dust Ignition-proof for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II, Groups E, F, and G / Suitable for Class III Hazardous Locations. / Install per Siemens drawing A5E02467236A. Temperature Code: T4 (-40°C < Ta < 60°C) CSA Enclosure Type 4X |
|
FM Division 2, Non-Incendive for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II, III, Division 1, Groups E, F, and G / Indoor and outdoor locations / NEMA Type 4X Temperature Code: T4 (-40°C < Ta < 60°C) |
FM Division 2, Non-Incendive for Class I, Division 2, Groups A, B, C, and D. Dust Ignition-proof for Class II, III, Division 1, Groups E, F, and G / Indoor and outdoor locations / NEMA Type 4X Temperature Code: T4 (-40°C < Ta < 60°C) |
|
ATEX type n, see note: Certificate number: Baseefa10ATEX0044X, ATEX marking: Ex II 3 G, Ex nA nL IIC T4 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V, ATEX Dust Ignition-proof: Certificate number: Baseefa10ATEX0045X, ATEX marking: II 3 D, Ex tD A22 IP66 T135 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V. Note on type n: Conditions for safe handling during installation: The device does not pass the 500 V insulation test in accordance with paragraph 6.8.1 of EN 60079-15:2005. This must be taken into account when installing the device. |
ATEX type n, see note: Certificate number: Baseefa10ATEX0044X, ATEX marking: Ex II 3 G, Ex nA nL IIC T4 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V, ATEX Dust Ignition-proof: Certificate number: Baseefa10ATEX0045X, ATEX marking: II 3 D, Ex tD A22 IP66 T135 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V. Note on type n: Conditions for safe handling during installation: The device does not pass the 500 V insulation test in accordance with paragraph 6.8.1 of EN 60079-15:2005. This must be taken into account when installing the device. |
|
IECEx type n, see note: Certificate number: IECEx BAS 10.0014X, Ex nA nL IIC T4 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V, IECEx Dust Ignition-proof, see note: Certificate number: IECEx BAS 10.0015X, Ex tD A22 IP66 T135 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V. Note on type n: Conditions for safe handling during installation: The device does not pass the 500 V insulation test in accordance with paragraph 6.8.1 of EN 60079-15:2005. This must be taken into account when installing the device. |
IECEx type n, see note: Certificate number: IECEx BAS 10.0014X, Ex nA nL IIC T4 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V, IECEx Dust Ignition-proof, see note: Certificate number: IECEx BAS 10.0015X, Ex tD A22 IP66 T135 (-40 °C <= Ta <= 60 °C), rated voltage: 28 V. Note on type n: Conditions for safe handling during installation: The device does not pass the 500 V insulation test in accordance with paragraph 6.8.1 of EN 60079-15:2005. This must be taken into account when installing the device. |
|
- |
- |
Wireless approval |
FCC and IC approval |
IC approval |