Order No. |
6GK1 105-2AA10 |
6GK1 105-2AB10 |
6GK1 105-2AC10 |
Product type designation |
OSM ITP62 |
OSM TP62 |
OSM ITP62-LD |
Transmission rate |
|||
Transmission rate 1 |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
Transmission rate 2 |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
Interfaces |
|||
Maximum number of electrical/optical connections for network components or terminal equipment |
8 |
8 |
8 |
Number of electrical connections |
|||
|
6 |
6 |
6 |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
Design of electrical connection |
|||
|
9-pin D-sub socket (10/100 Mbit/s) |
RJ45 socket |
9-pin D-sub socket (10/100 Mbit/s) |
|
on the 6-pin terminal block |
on the 6-pin terminal block |
on the 6-pin terminal block |
|
6-pin plug-in terminal block |
6-pin plug-in terminal block |
6-pin plug-in terminal block |
Number of optical connections for fiber-optic cables |
|||
|
2 |
2 |
2 |
Design of optical connection for fiber-optic cables |
|||
|
BFOC port (multimode up to 3 km) |
BFOC port (multimode up to 3 km) |
BFOC port (singlemode up to 26 km) |
Injectable optical power relative to 1 mW |
|||
|
- - |
- - |
- - |
|
- |
- |
- |
Minimum optical sensitivity relative to 1 mW of the receiver input |
- |
- |
- |
Minimum required attenuation factor of the FO transmission link |
- |
- |
- |
Inputs/outputs |
|||
Operating current of signaling contacts with AC maximum |
- |
- |
- |
Operating voltage of signaling contacts with DC rated value |
24 V |
24 V |
24 V |
Operating current of signal contacts with DC, maximum |
0.1 A |
0.1 A |
0.1 A |
Number of digital inputs |
8 |
8 |
8 |
Number of electrical connections for digital input signals |
2 |
2 |
2 |
Design of electrical connection for digital input signals |
4-pin plug-in terminal block |
4-pin plug-in terminal block |
4-pin plug-in terminal block |
Signal voltage for signal <0> with DC |
|||
|
-30 V |
-30 V |
-30 V |
|
3 V |
3 V |
3 V |
|
24 V |
24 V |
24 V |
Signal voltage for signal <1> with DC |
|||
|
13 V |
13 V |
13 V |
|
30 V |
30 V |
30 V |
|
24 V |
24 V |
24 V |
Input current at digital input |
|||
|
0.008 mA |
0.008 mA |
0.008 mA |
|
0.008 A |
0.008 A |
0.008 A |
Supply voltage, current consumption, power loss |
|||
Type of voltage |
|||
|
DC |
DC |
DC |
External power supply |
24 V |
24 V |
24 V |
|
18 V |
18 V |
18 V |
|
32 V |
32 V |
32 V |
Product component: fusing of power supply input |
Yes |
Yes |
Yes |
Type of fusing of power supply input |
T 1.6 A / 250 V |
T 1.6 A / 250 V |
T 1.6 A / 250 V |
Current consumption, maximum |
1 A |
1 A |
1 A |
Effective power loss at 24 V DC |
20 W |
20 W |
20 W |
Permissible ambient conditions |
|||
Ambient temperature |
|||
|
0 … 60 °C |
0 … 60 °C |
0 … 60 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-20 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-20 … +80 °C |
Relative humidity at 25 °C without condensation during operation, maximum |
95 % |
95 % |
95 % |
IP degree of protection |
IP20 |
IP20 |
IP20 |
Design, dimensions and weights |
|||
Width |
217 mm |
217 mm |
217 mm |
Height |
161 mm |
161 mm |
161 mm |
Depth |
69 mm |
69 mm |
69 mm |
Net weight |
1.4 kg |
1.4 kg |
1.4 kg |
Type of mounting |
|||
|
- |
- |
- |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
Product properties, functions, componentsGeneral |
|||
Cascading with redundant ring at reconfiguration time < 0.3 s |
50 |
50 |
50 |
Cascading with star topology |
Any (only dependent on signal propagation time) |
Any (only dependent on signal propagation time) |
Any (only dependent on signal propagation time) |
Product functions Management, configuration, programming |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
- |
- |
- |
|
Yes |
Yes |
Yes |
Protocol is supported |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsDiagnostics |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsDHCP |
|||
Product function: DHCP client |
Yes |
Yes |
Yes |
Product functionsRedundancy |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsTime |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
Standards, specifications, approvals |
|||
Standard |
|||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T.. A, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T.. A, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T.. A, CL.1, Zone 2, GP. IIC, T4 |
|
- |
- |
- |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
EN 61000-6-4 |
EN 61000-6-4 |
EN 61000-6-4 |
|
EN 61000-6-2 |
EN 61000-6-2 |
EN 61000-6-2 |
Certificate of suitability |
- |
- |
- |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Marine classification corporation |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Order No. |
6GK1 105-2AD10 |
6GK1 105-2AE00 |
6GK1 105-4AA00 |
Product type designation |
OSM ITP53 |
OSM TP22 |
OSM BC08 |
Transmission rate |
|||
Transmission rate 1 |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
Transmission rate 2 |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
Interfaces |
|||
Maximum number of electrical/optical connections for network components or terminal equipment |
8 |
4 |
8 |
Number of electrical connections |
|||
|
5 |
2 |
- |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
Design of electrical connection |
|||
|
9-pin D-sub socket (10/100 Mbit/s) |
RJ45 socket |
- |
|
on the 6-pin terminal block |
on the 6-pin terminal block |
on the 6-pin terminal block |
|
6-pin plug-in terminal block |
6-pin plug-in terminal block |
6-pin plug-in terminal block |
Number of optical connections for fiber-optic cables |
|||
|
3 |
2 |
8 |
Design of optical connection for fiber-optic cables |
|||
|
BFOC port (multimode up to 3 km) |
BFOC port (multimode up to 3 km) |
BFOC port (multimode up to 5 km) |
Injectable optical power relative to 1 mW |
|||
|
- - |
- - |
- - |
|
- |
- |
- |
Minimum optical sensitivity relative to 1 mW of the receiver input |
- |
- |
- |
Minimum required attenuation factor of the FO transmission link |
- |
- |
- |
Inputs/outputs |
|||
Operating current of signaling contacts with AC maximum |
- |
- |
- |
Operating voltage of signaling contacts with DC rated value |
24 V |
24 V |
24 V |
Operating current of signal contacts with DC, maximum |
0.1 A |
0.1 A |
0.1 A |
Number of digital inputs |
8 |
4 |
8 |
Number of electrical connections for digital input signals |
2 |
1 |
2 |
Design of electrical connection for digital input signals |
4-pin plug-in terminal block |
4-pin plug-in terminal block |
6-pin plug-in terminal block |
Signal voltage for signal <0> with DC |
|||
|
-30 V |
-30 V |
-30 V |
|
3 V |
3 V |
3 V |
|
24 V |
24 V |
24 V |
Signal voltage for signal <1> with DC |
|||
|
13 V |
13 V |
13 V |
|
30 V |
30 V |
30 V |
|
24 V |
24 V |
24 V |
Input current at digital input |
|||
|
0.008 mA |
0.008 mA |
0.008 mA |
|
0.008 A |
0.008 A |
0.008 A |
Supply voltage, current consumption, power loss |
|||
Type of voltage |
|||
|
DC |
DC |
DC |
External power supply |
24 V |
24 V |
24 V |
|
18 V |
18 V |
18 V |
|
32 V |
32 V |
32 V |
Product component: fusing of power supply input |
Yes |
Yes |
Yes |
Type of fusing of power supply input |
T 1.6 A / 250 V |
T 1.6 A / 250 V |
0.6 A / 60 V |
Current consumption, maximum |
1 A |
1 A |
1 A |
Effective power loss at 24 V DC |
20 W |
20 W |
20 W |
Permissible ambient conditions |
|||
Ambient temperature |
|||
|
0 … 60 °C |
0 … 60 °C |
0 … 60 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operation, maximum |
95 % |
95 % |
95 % |
IP degree of protection |
IP20 |
IP20 |
IP20 |
Design, dimensions and weights |
|||
Width |
217 mm |
217 mm |
217 mm |
Height |
161 mm |
161 mm |
161 mm |
Depth |
69 mm |
69 mm |
69 mm |
Net weight |
1.4 kg |
1.4 kg |
1.4 kg |
Type of mounting |
|||
|
- |
- |
- |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
Product properties, functions, componentsGeneral |
|||
Cascading with redundant ring with reconfiguration time < 0.3 s |
50 |
50 |
50 |
Cascading with star topology |
Any (only dependent on signal propagation time) |
Any (only dependent on signal propagation time) |
Any (only dependent on signal propagation time) |
Product functions Management, configuration, programming |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
- |
- |
- |
|
Yes |
Yes |
Yes |
Protocol is supported |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsDiagnostics |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsDHCP |
|||
Product function: DHCP client |
Yes |
Yes |
Yes |
Product functionsRedundancy |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsTime |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
Standards, specifications, approvals |
|||
Standard |
|||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T.. A, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T.. A, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T.. A, CL.1, Zone 2, GP. IIC, T4 |
|
- |
- |
- |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
EN 61000-6-4 |
EN 61000-6-4 |
EN 61000-6-4 |
|
EN 61000-6-2 |
EN 61000-6-2 |
EN 61000-6-2 |
Certificate of suitability |
- |
- |
- |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Marine classification corporation |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Order No. |
6GK1 105-3AA10 |
6GK1 105-3AB10 |
6GK1 105-3AC00 |
Product type designation |
ESM ITP80 |
ESM TP80 |
ESM TP40 |
Transmission rate |
|||
Transmission rate 1 |
10 Mbit/s |
10 Mbit/s |
10 Mbit/s |
Transmission rate 2 |
100 Mbit/s |
100 Mbit/s |
100 Mbit/s |
Interfaces |
|||
Maximum number of electrical/optical connections for network components or terminal equipment |
8 |
8 |
4 |
Number of electrical connections |
|||
|
8 |
8 |
4 |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
|
1 |
1 |
1 |
Design of electrical connection |
|||
|
9-pin D-sub socket (10/100 Mbit/s) |
RJ45 socket |
RJ45 socket |
|
on the 6-pin terminal block |
on the 6-pin terminal block |
on the 6-pin terminal block |
|
6-pin plug-in terminal block |
6-pin plug-in terminal block |
6-pin plug-in terminal block |
Number of optical connections for fiber-optic cables |
|||
|
- |
- |
- |
Design of optical connection for fiber-optic cables |
|||
|
- |
- |
- |
Injectable optical power relative to 1 mW |
|||
|
- - |
- - |
- - |
|
- |
- |
- |
Minimum optical sensitivity relative to 1 mW of the receiver input |
- |
- |
- |
Minimum required attenuation factor of the FO transmission link |
- |
- |
- |
Inputs/outputs |
|||
Operating current of signaling contacts with AC maximum |
- |
- |
- |
Operating voltage of signaling contacts with DC rated value |
24 V |
24 V |
24 V |
Operating current of signal contacts with DC, maximum |
0.1 A |
0.1 A |
0.1 A |
Number of digital inputs |
8 |
8 |
4 |
Number of electrical connections for digital input signals |
2 |
2 |
1 |
Design of electrical connection for digital input signals |
6-pin plug-in terminal block |
4-pin plug-in terminal block |
6-pin plug-in terminal block |
Signal voltage for signal <0> with DC |
|||
|
-30 V |
-30 V |
-30 V |
|
3 V |
3 V |
3 V |
|
24 V |
24 V |
24 V |
Signal voltage for signal <1> with DC |
|||
|
13 V |
13 V |
13 V |
|
30 V |
30 V |
30 V |
|
24 V |
24 V |
24 V |
Input current at digital input |
|||
|
0.008 mA |
0.008 mA |
0.008 mA |
|
0.008 A |
0.008 A |
0.008 A |
Supply voltage, current consumption, power loss |
|||
Type of voltage |
|||
|
DC |
DC |
DC |
External supply voltage |
24 V |
24 V |
24 V |
|
18 V |
18 V |
18 V |
|
32 V |
32 V |
32 V |
Product component: fusing at power supply input |
Yes |
Yes |
Yes |
Design of fusing at input for supply voltage |
T 1.6 A / 250 V |
T 1.6 A / 250 V |
T 1.6 A / 250 V |
Current consumption, maximum |
1 A |
1 A |
1 A |
Effective power loss at 24 V with DC |
20 W |
20 W |
20 W |
Permissible ambient conditions |
|||
Ambient temperature |
|||
|
0 … 60 °C |
0 … 60 °C |
0 … 60 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operation, maximum |
95 % |
95 % |
95 % |
IP degree of protection |
IP20 |
IP20 |
IP20 |
Design, dimensions and weights |
|||
Width |
217 mm |
217 mm |
217 mm |
Height |
161 mm |
161 mm |
161 mm |
Depth |
69 mm |
69 mm |
69 mm |
Net weight |
1.4 kg |
1.4 kg |
1.4 kg |
Type of mounting |
|||
|
- |
- |
- |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Type of mounting |
- |
- |
- |
Product properties, functions, components General |
|||
Cascading with redundant ring with reconfiguration time < 0.3 s |
50 |
50 |
50 |
Cascading with star topology |
Any (only dependent on signal propagation time) |
Any (only dependent on signal propagation time) |
Any (only dependent on signal propagation time) |
Product functions Management, configuration, programming |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
- |
- |
- |
|
Yes |
Yes |
Yes |
Protocol is supported |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsDiagnostics |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsDHCP |
|||
Product function: DHCP client |
Yes |
Yes |
Yes |
Product functionsRedundancy |
|||
Product function |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Product functionsTime |
|||
Product function: SICLOCK support |
Yes |
Yes |
Yes |
Standards, specifications, approvals |
|||
Standard |
|||
|
FM3611: Class 1, Division 2, Group A, B, C, D / T.. A, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T.. A, CL.1, Zone 2, GP. IIC, T4 |
FM3611: Class 1, Division 2, Group A, B, C, D / T.. A, CL.1, Zone 2, GP. IIC, T4 |
|
- |
- |
- |
|
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
UL 60950-1, CSA C22.2 No. 60950-1 |
|
EN 61000-6-4 |
EN 61000-6-4 |
EN 61000-6-4 |
|
EN 61000-6-2 |
EN 61000-6-2 |
EN 61000-6-2 |
Certificate of suitability |
- |
- |
- |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Marine classification corporation |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |