Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru
SCALANCE W-780 Access Points

Order No.

6GK5 788-1AA60-2AA0

6GK5 788-2AA60-2AA0

6GK5 788-1AA60-6AA0

6GK5 788-2AA60-6AA0

6GK5 788-1AA60-2AB0 1)

6GK5 788-2AA60-2AB0 1)

6GK5 788-1AA60-6AB0 1)

6GK5 788-2AA60-6AB0 1)

Product type designation

SCALANCE W788-1PRO

SCALANCE W788-2PRO

SCALANCE W788-1RR

SCALANCE W788-2RR

Transmission rate

Transmission rate

  • with W-LAN maximum

54 Mbit/s

54 Mbit/s

54 Mbit/s

54 Mbit/s

  • with Industrial Ethernet

10 … 100 Mbit/s

10 … 100 Mbit/s

10 … 100 Mbit/s

10 … 100 Mbit/s

  • note

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Interfaces

Number of electrical connections

  • for network components and terminal equipment

1

1

1

1

  • for power supply

1

1

1

1

  • for redundant power supply

1

1

1

1

Design of electrical connection

  • for network components and terminal equipment

Hybrid socket, RJ45 integrated

Hybrid socket, RJ45 integrated

Hybrid socket, RJ45 integrated

Hybrid socket, RJ45 integrated

  • for power supply

M12 interface (4-pole, A-coded), hybrid socket, PoE

M12 interface (4-pole, A-coded), hybrid socket, PoE

M12 interface (4-pole, A-coded), hybrid socket, PoE

M12 interface (4-pole, A-coded), hybrid socket, PoE

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Interfaceswireless

Number of radio cards permanently installed

1

2

1

2

Number of electrical connections for external antenna(s)

2

4

2

4

Design of the electrical connection for external antenna(s)

R-SMA female (socket)

R-SMA female (socket)

R-SMA female (socket)

R-SMA female (socket)

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage

  • 1 from M12 Power Connector (A-coded) for redundant power supply

24 V

24 V

24 V

24 V

  • 2 from M12 Power Connector (A-coded) for redundant power supply

48 V

48 V

48 V

48 V

  • 1 from IE Hybrid Cable 2x2 + 4x0.34

24 V

24 V

24 V

24 V

  • 2 from IE Hybrid Cable 2x2 + 4x0.34

48 V

48 V

48 V

48 V

  • from Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

48 V

48 V

48 V

48 V

Current consumed

  • at 24 V with DC typical

0.25 A

0.295 A

0.25 A

0.295 A

  • at 48 V with DC typical

0.125 A

0.15 A

0.125 A

0.15 A

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

0.125 A

0.15 A

0.125 A

0.15 A

Effective power loss

  • at 24V for DC typical

7 W

7 W

7 W

9 W

  • at 48 V with DC typical

7 W

7 W

7 W

9 W

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

7 W

7 W

7 W

9 W

Permitted ambient conditions

Ambient temperature

  • during operating

-20 … +60 °C

-20 … +60 °C

-20 … +60 °C

-20 … +60 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

Relative humidity at 25 °C without condensation during operating maximum

100 %

100 %

100 %

100 %

Protection class IP

IP65

IP65

IP65

IP65

Ambient condition for (standard) operation mode

When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529.

When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529.

When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529.

When used under hazardous conditions (Zone 2), the SCALANCE W788-xPRO/RR or W74x-1PRO/RR product must be installed in an enclosure. To comply with EN 50021, this enclosure must meet the requirements of at least IP 54 in compliance with EN 60529.

Design, dimensions and weight

Width of enclosure without antenna

125 mm

125 mm

125 mm

125 mm

Height of enclosure without antenna

88 mm

88 mm

88 mm

88 mm

Depth of enclosure without antenna

108 mm

108 mm

108 mm

108 mm

Net weight

1.05 kg

1.05 kg

1.05 kg

1.05 kg

Type of mounting

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

Wireless frequencies

Radio frequency

  • for WLAN in 2.4 GHz frequency band

2.41 … 2.48 GHz

2.41 … 2.48 GHz

2.41 … 2.48 GHz

2.41 … 2.48 GHz

  • for WLAN in 5 GHz frequency band

4.9 … 5.8 GHz

4.9 … 5.8 GHz

4.9 … 5.8 GHz

4.9 … 5.8 GHz

Product properties, functions, componentsgeneral

Number of SSIDs

8

16

8

16

Product function

  • Dual Client

No

No

Yes

Yes

  • iHOP

No

No

Yes

Yes

  • iPCF

No

No

Yes

Yes

  • iPCF-MC

No

No

No

Yes

Number of iPCF-capable radio modules

0

0

1

1

Product functionsmanagement, configuration

Number of manageable IP addresses in client

8

8

8

8

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • configuration with STEP 7 in the TIA Portal

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • operation with IWLAN controller

No

No

No

No

  • operation with Enterasys WLAN controller

No

No

No

No

  • iQoS

Yes

Yes

Yes

Yes

  • forced roaming with IWLAN

Yes

Yes

Yes

Yes

  • WDS

Yes

Yes

Yes

Yes

Protocol is supported

  • Address Resolution Protocol (ARP)

Yes

Yes

Yes

Yes

  • ICMP

Yes

Yes

Yes

Yes

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • Link Check

Yes

Yes

Yes

Yes

  • connection monitoring IP-Alive

Yes

Yes

Yes

Yes

  • localization via Aeroscout

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function function VLAN with IWLAN

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function DHCP client

Yes

Yes

Yes

Yes

Product functionsRedundancy

Protocol is supported STP/RSTP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • NAT/NAPT

Yes

Yes

Yes

Yes

  • access protection according to IEEE802.11i

Yes

Yes

Yes

Yes

  • WPA/WPA2

Yes

Yes

Yes

Yes

  • TKIP/AES

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Protocol is supported SNTP

Yes

Yes

Yes

Yes

Standards, specifications, approvals

Standard

  • for EMC from FM

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4

ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4

ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4

ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4

Certificate of suitability

  • CE mark

Yes

Yes

Yes

Yes

  • EC declaration of conformity

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • CCC

No

No

No

No

  • Railway application in accordance with EN 50155

Yes

Yes

Yes

Yes

  • e1 approval

Yes

Yes

Yes

Yes

  • E1 approval

Yes

Yes

Yes

Yes

  • Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

Yes

Yes

Yes

Yes

Standard for wireless communication

  • IEEE 802.11a

Yes

Yes

Yes

Yes

  • IEEE 802.11b

Yes

Yes

Yes

Yes

  • IEEE 802.11e

Yes

Yes

Yes

Yes

  • IEEE 802.11g

Yes

Yes

Yes

Yes

  • IEEE 802.11h

Yes

Yes

Yes

Yes

  • IEEE 802.11i

Yes

Yes

Yes

Yes

  • IEEE 802.11n

No

No

No

No

Wireless approval

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

No

No

No

No

  • Germanische Lloyd (GL)

Yes

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

Yes

Marine classification association / Polski Rejestr Statkow (PRS)

Yes

Yes

Yes

Yes

Accessories

Accessories

2 antennas, hybrid connector included in scope of delivery

2 antennas, hybrid connector included in scope of delivery

2 antennas, hybrid connector included in scope of delivery

2 antennas, hybrid connector included in scope of delivery


1)  Wireless approval in the USA

Order No.

6GK5 786-1BA60-2AA0

6GK5 786-1AA60-2AA0

6GK5 786-1BB60-2AA0

6GK5 786-1AB60-2AA0

6GK5 786-1BA60-2AB0 1)

6GK5 786-1AA60-2AB0 1)

6GK5 786-1BB60-2AB0 1)

6GK5 786-1AB60-2AB0 1)

Product type designation

SCALANCE W786-1PRO

SCALANCE W786-1PRO

SCALANCE W786-1PRO

SCALANCE W786-1PRO

Transmission rate

Transmission rate

  • with W-LAN maximum

54 Mbit/s

54 Mbit/s

54 Mbit/s

54 Mbit/s

  • with Industrial Ethernet

10 … 100 Mbit/s

10 … 100 Mbit/s

10 … 100 Mbit/s

10 … 100 Mbit/s

  • note

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Interfaces

Number of electrical connections

  • for network components and terminal equipment

1

1

-

-

  • for power supply

1

1

1

1

  • for redundant power supply

1

1

1

1

Design of electrical connection

  • for network components and terminal equipment

RJ45 socket

RJ45 socket

-

-

  • for power supply

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

Number of optical interfaces for optical waveguide at 100 Mbit/s

-

-

1

1

Design of optical interface for optical waveguide at 100 Mbit/s

-

-

Duplex multimode FOC (ST)

Duplex multimode FOC (ST)

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Interfaceswireless

Number of radio cards permanently installed

1

1

1

1

Number of internal antennas

2

-

2

-

Number of electrical connections for external antenna(s)

-

2

-

2

Design of the electrical connection for external antenna(s)

-

R-SMA female (socket)

-

R-SMA female (socket)

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage

  • 1 from terminal block

48 V

48 V

48 V

48 V

  • 2 from terminal block

-

-

-

-

  • from Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

48 V

48 V

48 V

48 V

  • from optional integratable power supply

    • with AC

100 … 240 V

100 … 240 V

100 … 240 V

100 … 240 V

    • with DC

12 … 24 V

12 … 24 V

12 … 24 V

12 … 24 V

Current consumed

  • at 24 V with DC typical

0.28 A

0.28 A

0.34 A

0.34 A

  • at 48 V with DC typical

0.14 A

0.14 A

0.17 A

0.17 A

  • at 230 V with AC typical

0.03 A

0.03 A

0.04 A

0.04 A

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

0.14 A

0.14 A

0.34 A

0.34 A

Effective power loss

  • at 24V for DC typical

6.5 W

6.5 W

8 W

8 W

  • at 48 V with DC typical

6.5 W

6.5 W

8 W

8 W

  • at 230 V with AC typical

6.5 W

6.5 W

8 W

8 W

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

6.5 W

6.5 W

8 W

8 W

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

  • during transport

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

Relative humidity at 25 °C without condensation during operating maximum

100 %

100 %

100 %

100 %

Protection class IP

IP65

IP65

IP65

IP65

Ambient condition for (standard) operation mode

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

Design, dimensions and weight

Width of enclosure without antenna

251 mm

251 mm

251 mm

251 mm

Height of enclosure without antenna

251 mm

251 mm

251 mm

251 mm

Depth of enclosure without antenna

72 mm

72 mm

72 mm

72 mm

Net weight

2.24 kg

2.24 kg

2.24 kg

2.24 kg

Type of mounting

  • S7-300 rail mounting

-

-

-

-

  • wall mounting

Yes

Yes

Yes

Yes

Type of mounting

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

Wireless frequencies

Radio frequency

  • for WLAN in 2.4 GHz frequency band

2.41 … 2.48 GHz

2.41 … 2.48 GHz

2.41 … 2.48 GHz

2.41 … 2.48 GHz

  • for WLAN in 5 GHz frequency band

4.9 … 5.8 GHz

4.9 … 5.8 GHz

4.9 … 5.8 GHz

4.9 … 5.8 GHz

Product properties, functions, componentsgeneral

Number of SSIDs

8

8

8

8

Product function

  • Dual Client

No

No

No

No

  • iHOP

No

No

No

No

  • iPCF

No

No

No

No

  • iPCF-MC

No

No

No

No

Number of iPCF-capable radio modules

0

0

0

0

Product functionsmanagement, configuration

Number of manageable IP addresses in client

8

8

8

8

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • configuration with STEP 7 in the TIA Portal

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • operation with IWLAN controller

No

No

No

No

  • operation with Enterasys WLAN controller

No

No

No

No

  • iQoS

Yes

Yes

Yes

Yes

  • forced roaming with IWLAN

Yes

Yes

Yes

Yes

  • WDS

Yes

Yes

Yes

Yes

Protocol is supported

  • Address Resolution Protocol (ARP)

Yes

Yes

Yes

Yes

  • ICMP

Yes

Yes

Yes

Yes

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • Link Check

Yes

Yes

Yes

Yes

  • connection monitoring IP-Alive

Yes

Yes

Yes

Yes

  • localization via Aeroscout

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function function VLAN with IWLAN

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function DHCP client

Yes

Yes

Yes

Yes

Product functionsRedundancy

Protocol is supported STP/RSTP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • NAT/NAPT

Yes

Yes

Yes

Yes

  • access protection according to IEEE802.11i

Yes

Yes

Yes

Yes

  • WPA/WPA2

Yes

Yes

Yes

Yes

  • TKIP/AES

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Protocol is supported SNTP

Yes

Yes

Yes

Yes

Standards, specifications, approvals

Standard

  • for EMC from FM

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

Certificate of suitability

  • CE mark

Yes

Yes

Yes

Yes

  • EC declaration of conformity

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • CCC

No

No

No

No

  • Railway application in accordance with EN 50155

No

No

No

No

  • e1 approval

Yes

Yes

Yes

Yes

  • E1 approval

Yes

Yes

Yes

Yes

  • NEMA4X

Yes

Yes

Yes

Yes

  • Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

Yes

Yes

Yes

Yes

Standard for wireless communication

  • IEEE 802.11a

Yes

Yes

Yes

Yes

  • IEEE 802.11b

Yes

Yes

Yes

Yes

  • IEEE 802.11e

Yes

Yes

Yes

Yes

  • IEEE 802.11g

Yes

Yes

Yes

Yes

  • IEEE 802.11h

Yes

Yes

Yes

Yes

  • IEEE 802.11i

Yes

Yes

Yes

Yes

  • IEEE 802.11n

No

No

No

No

Wireless approval

You can find the current list of countries at: www.siemens.com/simatic-net/ik-info

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

No

No

No

No

  • Germanische Lloyd (GL)

Yes

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

Yes

Marine classification association / Polski Rejestr Statkow (PRS)

No

No

No

No

Accessories

Accessories

48 V DC screw terminal included in scope of delivery

48 V DC screw terminal included in scope of delivery

48 V DC screw terminal included in scope of delivery

48 V DC screw terminal included in scope of delivery


1)  Wireless approval in the USA

Order No.

6GK5 786-2BA60-2AA0

6GK5 786-2AA60-2AA0

6GK5 786-2BB60-2AA0

6GK5 786-2AB60-2AA0

6GK5 786-2BA60-2AB0 1)

6GK5 786-2AA60-2AB0 1)

6GK5 786-2BB60-2AB0 1)

6GK5 786-2AB60-2AB0 1)

Product type designation

SCALANCE W786-2PRO

SCALANCE W786-2PRO

SCALANCE W786-2PRO

SCALANCE W786-2PRO

Transmission rate

Transmission rate

  • with W-LAN maximum

54 Mbit/s

54 Mbit/s

54 Mbit/s

54 Mbit/s

  • with Industrial Ethernet

10 … 100 Mbit/s

10 … 100 Mbit/s

10 … 100 Mbit/s

10 … 100 Mbit/s

  • note

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Interfaces

Number of electrical connections

  • for network components and terminal equipment

1

1

-

-

  • for power supply

1

1

1

1

  • for redundant power supply

1

1

1

1

Design of electrical connection

  • for network components and terminal equipment

RJ45 socket

RJ45 socket

-

-

  • for power supply

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

Number of optical interfaces for optical waveguide at 100 Mbit/s

-

-

1

1

Design of optical interface for optical waveguide at 100 Mbit/s

-

-

Duplex multimode FOC (ST)

Duplex multimode FOC (ST)

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Interfaceswireless

Number of radio cards permanently installed

2

2

2

2

Number of internal antennas

4

-

4

-

Number of electrical connections for external antenna(s)

-

4

-

4

Design of the electrical connection for external antenna(s)

-

R-SMA female (socket)

-

R-SMA female (socket)

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage

  • 1 from terminal block

48 V

48 V

48 V

48 V

  • 2 from terminal block

-

-

-

-

  • from Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

48 V

48 V

48 V

48 V

  • from optional integratable power supply

    • with AC

100 … 240 V

100 … 240 V

100 … 240 V

100 … 240 V

    • with DC

12 … 24 V

12 … 24 V

12 … 24 V

12 … 24 V

Current consumed

  • at 24 V with DC typical

0.34 A

0.34 A

0.4 A

0.4 A

  • at 48 V with DC typical

0.17 A

0.17 A

0.2 A

0.2 A

  • at 230 V with AC typical

0.04 A

0.04 A

0.05 A

0.05 A

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

0.34 A

0.34 A

0.2 A

0.2 A

Effective power loss

  • at 24V for DC typical

8 W

8 W

9.5 W

9.5 W

  • at 48 V with DC typical

8 W

8 W

9.5 W

9.5 W

  • at 230 V with AC typical

8 W

8 W

9.5 W

9.5 W

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

8 W

8 W

9.5 W

9.5 W

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

  • during transport

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

Relative humidity at 25 °C without condensation during operating maximum

100 %

100 %

100 %

100 %

Protection class IP

IP65

IP65

IP65

IP65

Ambient condition for (standard) operation mode

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

Design, dimensions and weight

Width of enclosure without antenna

251 mm

251 mm

251 mm

251 mm

Height of enclosure without antenna

251 mm

251 mm

251 mm

251 mm

Depth of enclosure without antenna

72 mm

72 mm

72 mm

72 mm

Net weight

2.24 kg

2.24 kg

2.24 kg

2.24 kg

Type of mounting

  • S7-300 rail mounting

-

-

-

-

  • wall mounting

Yes

Yes

Yes

Yes

Type of mounting

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

Wireless frequencies

Radio frequency

  • for WLAN in 2.4 GHz frequency band

2.41 … 2.48 GHz

2.41 … 2.48 GHz

2.41 … 2.48 GHz

2.41 … 2.48 GHz

  • for WLAN in 5 GHz frequency band

4.9 … 5.8 GHz

4.9 … 5.8 GHz

4.9 … 5.8 GHz

4.9 … 5.8 GHz

Product properties, functions, componentsgeneral

Number of SSIDs

16

16

16

16

Product function

  • Dual Client

No

No

No

No

  • iHOP

No

No

No

No

  • iPCF

No

No

No

No

  • iPCF-MC

No

No

No

No

Number of iPCF-capable radio modules

0

0

0

0

Product functionsmanagement, configuration

Number of manageable IP addresses in client

8

8

8

8

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • configuration with STEP 7 in the TIA Portal

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • operation with IWLAN controller

No

No

No

No

  • operation with Enterasys WLAN controller

No

No

No

No

  • iQoS

Yes

Yes

Yes

Yes

  • forced roaming with IWLAN

Yes

Yes

Yes

Yes

  • WDS

Yes

Yes

Yes

Yes

Protocol is supported

  • Address Resolution Protocol (ARP)

Yes

Yes

Yes

Yes

  • ICMP

Yes

Yes

Yes

Yes

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • Link Check

Yes

Yes

Yes

Yes

  • connection monitoring IP-Alive

Yes

Yes

Yes

Yes

  • localization via Aeroscout

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function function VLAN with IWLAN

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function DHCP client

Yes

Yes

Yes

Yes

Product functionsRedundancy

Protocol is supported STP/RSTP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • NAT/NAPT

Yes

Yes

Yes

Yes

  • access protection according to IEEE802.11i

Yes

Yes

Yes

Yes

  • WPA/WPA2

Yes

Yes

Yes

Yes

  • TKIP/AES

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Protocol is supported SNTP

Yes

Yes

Yes

Yes

Standards, specifications, approvals

Standard

  • for EMC from FM

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

Certificate of suitability

  • CE mark

Yes

Yes

Yes

Yes

  • EC declaration of conformity

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • CCC

No

No

No

No

  • Railway application in accordance with EN 50155

No

No

No

No

  • e1 approval

Yes

Yes

Yes

Yes

  • E1 approval

Yes

Yes

Yes

Yes

  • NEMA4X

Yes

Yes

Yes

Yes

  • Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

Yes

Yes

Yes

Yes

Standard for wireless communication

  • IEEE 802.11a

Yes

Yes

Yes

Yes

  • IEEE 802.11b

Yes

Yes

Yes

Yes

  • IEEE 802.11e

Yes

Yes

Yes

Yes

  • IEEE 802.11g

Yes

Yes

Yes

Yes

  • IEEE 802.11h

Yes

Yes

Yes

Yes

  • IEEE 802.11i

Yes

Yes

Yes

Yes

  • IEEE 802.11n

No

No

No

No

Wireless approval

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

No

No

No

No

  • Germanische Lloyd (GL)

Yes

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

Yes

Marine classification association/ Polski Rejestr Statkow (PRS)

No

No

No

No

Accessories

Accessories

48 V DC screw terminal included in scope of delivery

48 V DC screw terminal included in scope of delivery

48 V DC screw terminal included in scope of delivery

48 V DC screw terminal included in scope of delivery


1)  Wireless approval in the USA

Order No.

6GK5 786-3AA60-2AA0

6GK5 786-3AB60-2AA0

6GK5 786-2BA60-6AA0

6GK5 786-2AA60-6AA0

6GK5 786-3AA60-2AB0 1)

6GK5 786-3AB60-2AB0 1)

6GK5 786-2BA60-6AB0 1)

6GK5 786-2AA60-6AB0 1)

Product type designation

SCALANCE W786-3PRO

SCALANCE W786-3PRO

SCALANCE W786-2RR

SCALANCE W786-2RR

Transmission rate

Transmission rate

  • with W-LAN maximum

54 Mbit/s

54 Mbit/s

54 Mbit/s

54 Mbit/s

  • with Industrial Ethernet

10 … 100 Mbit/s

10 … 100 Mbit/s

10 … 100 Mbit/s

10 … 100 Mbit/s

  • note

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Interfaces

Number of electrical connections

  • for network components and terminal equipment

1

-

1

1

  • for power supply

1

1

1

1

  • for redundant power supply

1

1

1

1

Design of electrical connection

  • for network components and terminal equipment

RJ45 socket

-

RJ45 socket

RJ45 socket

  • for power supply

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

2-pole connector (48 V DC) or optionally available power supply adapter (4-pole 12 to 24 V DC or 3-pole 100 to 240 V AC)

Number of optical interfaces for optical waveguide at 100 Mbit/s

-

1

-

-

Design of optical interface for optical waveguide at 100 Mbit/s

-

Duplex multimode FOC (ST)

-

-

design of the removable storage C-PLUG

Yes

Yes

Yes

Yes

Interfaceswireless

Number of radio cards permanently installed

3

3

2

2

Number of internal antennas

-

-

4

-

Number of electrical connections for external antenna(s)

6

6

-

4

Design of the electrical connection for external antenna(s)

R-SMA female (socket)

R-SMA female (socket)

-

R-SMA female (socket)

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage

  • 1 from terminal block

48 V

48 V

48 V

48 V

  • 2 from terminal block

-

-

-

-

  • from Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

48 V

48 V

48 V

48 V

  • from optional integratable power supply

    • with AC

100 … 240 V

100 … 240 V

100 … 240 V

100 … 240 V

    • with DC

12 … 24 V

12 … 24 V

12 … 24 V

12 … 24 V

Current consumed

  • at 24 V with DC typical

0.4 A

0.46 A

0.34 A

0.34 A

  • at 48 V with DC typical

0.2 A

0.23 A

0.17 A

0.17 A

  • at 230 V with AC typical

0.05 A

0.05 A

0.04 A

0.04 A

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

0.2 A

0.23 A

0.34 A

0.34 A

Effective power loss

  • at 24V for DC typical

9.5 W

11 W

8 W

8 W

  • at 48 V with DC typical

9.5 W

11 W

8 W

8 W

  • at 230 V with AC typical

9.5 W

11 W

8 W

8 W

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

9.5 W

11 W

8 W

8 W

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

  • during transport

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

-40 … +85 °C

Relative humidity at 25 °C without condensation during operating maximum

100 %

100 %

100 %

100 %

Protection class IP

IP65

IP65

IP65

IP65

Ambient condition for (standard) operation mode

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

When using the power supply 100 to 240 V AC, an operating temperature of -40 °C to +60 °C is permissible

Design, dimensions and weight

Width of enclosure without antenna

251 mm

251 mm

251 mm

251 mm

Height of enclosure without antenna

251 mm

251 mm

251 mm

251 mm

Depth of enclosure without antenna

72 mm

72 mm

72 mm

72 mm

Net weight

2.24 kg

2.24 kg

2.24 kg

2.24 kg

Type of mounting

  • S7-300 rail mounting

-

-

-

-

  • wall mounting

Yes

Yes

Yes

Yes

Type of mounting

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

For mast mounting, 35 mm DIN rail mounting and S7-300 rail mounting, an additional support plate is required

Wireless frequencies

Radio frequency

  • for WLAN in 2.4 GHz frequency band

2.41 … 2.48 GHz

2.41 … 2.48 GHz

2.41 … 2.48 GHz

2.41 … 2.48 GHz

  • for WLAN in 5 GHz frequency band

4.9 … 5.8 GHz

4.9 … 5.8 GHz

4.9 … 5.8 GHz

4.9 … 5.8 GHz

Product properties, functions, componentsgeneral

Number of SSIDs

24

24

16

16

Product function

  • Dual Client

No

No

Yes

Yes

  • iHOP

No

No

Yes

Yes

  • iPCF

No

No

Yes

Yes

  • iPCF-MC

No

No

Yes

Yes

Number of iPCF-capable radio modules

0

0

1

1

Product functionsmanagement, configuration

Number of manageable IP addresses in client

8

8

8

8

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • configuration with STEP 7 in the TIA Portal

Yes

Yes

Yes

Yes

  • SMTP server

Yes

Yes

Yes

Yes

  • operation with IWLAN controller

No

No

No

No

  • operation with Enterasys WLAN controller

No

No

No

No

  • iQoS

Yes

Yes

Yes

Yes

  • forced roaming with IWLAN

Yes

Yes

Yes

Yes

  • WDS

Yes

Yes

Yes

Yes

Protocol is supported

  • Address Resolution Protocol (ARP)

Yes

Yes

Yes

Yes

  • ICMP

Yes

Yes

Yes

Yes

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Yes

Yes

Product functionsDiagnosis

Product function

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • Link Check

Yes

Yes

Yes

Yes

  • connection monitoring IP-Alive

Yes

Yes

Yes

Yes

  • localization via Aeroscout

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functionsVLAN

Product function function VLAN with IWLAN

Yes

Yes

Yes

Yes

Product functionsDHCP

Product function DHCP client

Yes

Yes

Yes

Yes

Product functionsRedundancy

Protocol is supported STP/RSTP

Yes

Yes

Yes

Yes

Product functionsSecurity

Product function

  • ACL - MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • NAT/NAPT

Yes

Yes

Yes

Yes

  • access protection according to IEEE802.11i

Yes

Yes

Yes

Yes

  • WPA/WPA2

Yes

Yes

Yes

Yes

  • TKIP/AES

Yes

Yes

Yes

Yes

Protocol is supported SSH

Yes

Yes

Yes

Yes

Product functionsTime

Protocol is supported SNTP

Yes

Yes

Yes

Yes

Standards, specifications, approvals

Standard

  • for EMC from FM

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety of CSA and UL

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

UL 1604, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4

Certificate of suitability

  • CE mark

Yes

Yes

Yes

Yes

  • EC declaration of conformity

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • CCC

No

No

No

No

  • Railway application in accordance with EN 50155

No

No

No

No

  • e1 approval

Yes

Yes

Yes

Yes

  • E1 approval

Yes

Yes

Yes

Yes

  • NEMA4X

Yes

Yes

Yes

Yes

  • Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

Yes

Yes

Yes

Yes

Standard for wireless communication

  • IEEE 802.11a

Yes

Yes

Yes

Yes

  • IEEE 802.11b

Yes

Yes

Yes

Yes

  • IEEE 802.11e

Yes

Yes

Yes

Yes

  • IEEE 802.11g

Yes

Yes

Yes

Yes

  • IEEE 802.11h

Yes

Yes

Yes

Yes

  • IEEE 802.11i

Yes

Yes

Yes

Yes

  • IEEE 802.11n

No

No

No

No

Wireless approval

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

No

No

No

No

  • Germanische Lloyd (GL)

Yes

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

Yes

Marine classification association/ Polski Rejestr Statkow (PRS)

No

No

No

No

Accessories

Accessories

48 V DC screw terminal included in scope of delivery

48 V DC screw terminal included in scope of delivery

48 V DC screw terminal included in scope of delivery

48 V DC screw terminal included in scope of delivery


1)  Wireless approval in the USA

Order No.

6GK5 784-1AA30-2AA0

6GK5 784-1AA30-6AA0

6GK5 784-1AA30-2AB0 1)

6GK5 784-1AA30-6AB0 1)

Product type designation

SCALANCE W784-1

SCALANCE W784-1RR

Transmission rate

Transmission rate

  • with W-LAN maximum

54 Mbit/s

54 Mbit/s

  • with Industrial Ethernet

10 … 100 Mbit/s

10 … 100 Mbit/s

  • note

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Due to the simultaneous use of several radio channels, a transmission rate of 108 Mbit/s is possible (turbo mode)

Interfaces

Number of electrical connections

  • for network components and terminal equipment

1

1

  • for power supply

1

1

  • for redundant power supply

1

1

Design of electrical connection

  • for network components and terminal equipment

RJ45 socket

RJ45 socket

  • for power supply

4-pole screw terminal, PoE

4-pole screw terminal, PoE

design of the removable storage C-PLUG

Yes

Yes

Interfaceswireless

Number of radio cards permanently installed

1

1

Number of electrical connections for external antenna(s)

2

2

Design of the electrical connection for external antenna(s)

R-SMA female (socket)

R-SMA female (socket)

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

Supply voltage

  • 1 from terminal block

24 V

24 V

  • 2 from terminal block

48 V

48 V

  • from Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

48 V

48 V

Current consumed

  • at 24 V with DC typical

0.23 A

0.23 A

  • at 48 V with DC typical

0.12 A

0.12 A

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

0.12 A

0.12 A

Effective power loss

  • at 24V for DC typical

6 W

6 W

  • at 48 V with DC typical

6 W

6 W

  • with Power-over-Ethernet according to IEEE802.3at for type 1 and IEEE802.3af typical

6 W

6 W

Permitted ambient conditions

Ambient temperature

  • during operating

-20 … +60 °C

-20 … +60 °C

  • during storage

-40 … +70 °C

-40 … +70 °C

  • during transport

-40 … +70 °C

-40 … +70 °C

Relative humidity at 25 °C without condensation during operating maximum

90 %

90 %

Protection class IP

IP30

IP30

Ambient condition for (standard) operation mode

-

-

Design, dimensions and weight

Width of enclosure without antenna

100 mm

100 mm

Height of enclosure without antenna

205 mm

205 mm

Depth of enclosure without antenna

20 mm

20 mm

Net weight

0.29 kg

0.29 kg

Type of mounting

  • S7-300 rail mounting

-

-

  • wall mounting

Yes

Yes

Type of mounting

For mounting on 35 mm DIN and S7-300 mounting rail, an additional adapter plate is required

For mounting on 35 mm DIN and S7-300 mounting rail, an additional adapter plate is required

Wireless frequencies

Radio frequency

  • for WLAN in 2.4 GHz frequency band

2.41 … 2.48 GHz

2.41 … 2.48 GHz

  • for WLAN in 5 GHz frequency band

4.9 … 5.8 GHz

4.9 … 5.8 GHz

Product properties, functions, componentsgeneral

Number of SSIDs

8

8

Product function

  • Dual Client

No

Yes

  • iHOP

No

Yes

  • iPCF

No

Yes

  • iPCF-MC

No

No

Number of iPCF-capable radio modules

0

1

Product functionsmanagement, configuration

Number of manageable IP addresses in client

8

8

Product function

  • CLI

Yes

Yes

  • web-based management

Yes

Yes

  • MIB support

Yes

Yes

  • TRAPs via email

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

  • configuration with STEP 7 in the TIA Portal

Yes

Yes

  • SMTP server

Yes

Yes

  • operation with IWLAN controller

No

No

  • operation with Enterasys WLAN controller

No

No

  • iQoS

Yes

Yes

  • forced roaming with IWLAN

Yes

Yes

  • WDS

Yes

Yes

Protocol is supported

  • Address Resolution Protocol (ARP)

Yes

Yes

  • ICMP

Yes

Yes

  • Telnet

Yes

Yes

  • HTTP

Yes

Yes

  • HTTPS

Yes

Yes

  • TFTP

Yes

Yes

  • SNMP v1

Yes

Yes

  • SNMP v2

Yes

Yes

  • SNMP v3

Yes

Yes

  • DCP

Yes

Yes

  • LLDP

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Product functionsDiagnosis

Product function

  • PROFINET IO diagnosis

Yes

Yes

  • Link Check

Yes

Yes

  • connection monitoring IP-Alive

Yes

Yes

  • localization via Aeroscout

Yes

Yes

  • SysLog

Yes

Yes

Product functionsVLAN

Product function function VLAN with IWLAN

Yes

Yes

Product functionsDHCP

Product function DHCP client

Yes

Yes

Product functionsRedundancy

Protocol is supported STP/RSTP

Yes

Yes

Product functionsSecurity

Product function

  • ACL - MAC-based

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

  • NAT/NAPT

Yes

Yes

  • access protection according to IEEE802.11i

Yes

Yes

  • WPA/WPA2

Yes

Yes

  • TKIP/AES

Yes

Yes

Protocol is supported SSH

Yes

Yes

Product functionsTime

Protocol is supported SNTP

Yes

Yes

Standards, specifications, approvals

Standard

  • for EMC from FM

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

FM 3611: Class I, Division 2, Groups A,B,C,D, T4 / Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X (only approved in combination with an enclosure with degree of protection of at least IP 54)

EN 60079-15:2005, EN 60079-0:2006, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X (only approved in combination with an enclosure with degree of protection of at least IP 54)

  • for safety of CSA and UL

UL 60950-1 CSA C22.2 No. 60950-1

UL 60950-1 CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 (only approved in combination with an enclosure with degree of protection of at least IP 54)

ISA 12.12.01-2000, CSA C22.2 No. 213-M1987, CL. 1, Div. 2, GP. A,B,C,D, T4 / CL. 1, Zone 2, GP IIC, T4 / CL. 1, Zone 2, AEx nC IIC, T4 (only approved in combination with an enclosure with degree of protection of at least IP 54)

Certificate of suitability

  • CE mark

Yes

Yes

  • EC declaration of conformity

Yes

Yes

  • C-Tick

Yes

Yes

  • CCC

No

No

  • Railway application in accordance with EN 50155

Yes

Yes

  • e1 approval

Yes

Yes

  • E1 approval

Yes

Yes

  • Power-over-Ethernet according IEEE802.3at for type 1 and IEEE802.3af

Yes

Yes

Standard for wireless communication

  • IEEE 802.11a

Yes

Yes

  • IEEE 802.11b

Yes

Yes

  • IEEE 802.11e

Yes

Yes

  • IEEE 802.11g

Yes

Yes

  • IEEE 802.11h

Yes

Yes

  • IEEE 802.11i

Yes

Yes

  • IEEE 802.11n

No

No

Wireless approval

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

  • Det Norske Veritas (DNV)

No

No

  • Germanische Lloyd (GL)

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Marine classification association/ Polski Rejestr Statkow (PRS)

No

No

Accessories

Accessories

24 V DC screw terminal included in scope of delivery

24 V DC screw terminal included in scope of delivery


1)  Wireless approval in the USA























































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET ECOFAST Введение Industrial Ethernet PROFINET Введение Привода Контроллеры Распределенная периферия Система управления перемещениями SIMOTION Системы ЧПУ SINUMERIK Устройства отображения и контроля Системы Человеко-Машинного Интерфейса Активные сетевые компоненты Промышленные ПК Производственные датчики Пассивные сетевые компоненты Сетевые компоненты для Industrial Ethernet Industrial Ethernet коммутаторы Безопасность передачи данных в промышленных сетях Промышленная мобильная коммуникация Точки доступа SCALANCE W-780 Клиентские модули SCALANCE W-740 Беспрводные устройства Коаксиальный кабель RCoax Аксессуары SINEMA E Lean Маршрутизаторы Аппаратура управления Датчики Инжиниринговые пакеты Технологические компоненты PROFINET Системный интерфейс к SIMATIC HMI PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366
Яндекс.Метрика