Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru
POF and PCF fiber-optic cable

6XV1 874-2A

6XV1 874-2B

Product type designation

POF Standard Cable GP

POF Trailing Cable

Product description

Fiber-optic cable with poly-optical fiber, sold by the meter, non-assembled

Fiber-optic cable with poly-optical fiber, sold by the meter, non-assembled

Suitability for application

Cable for fixed installation indoors, UL approval

Cable for moving applications (e.g. trailing cables)

Design of preassembled FO cable

Can be fitted with SC RJ or SC RJ Plug PRO connectors

Can be fitted with SC RJ or SC RJ Plug PRO connectors

Cable designation

I-V4Y(ZN)Y 2P 980/1000

I-V4Y(ZN)11Y 2P 980/1000 FLEX UL

Cable length

-

-

Optical data

Maximum damping factor per length at 650 nm

0.16 dB/m

0.18 dB/m

Bandwidth length product at 650 nm

1 GHz·m

1 GHz·m

Mechanical data

Number of fibers per FO core

1

1

Number of FO cores per FO cable

2

2

Design of FO fiber

Plastic optical fiber 980/1000 µm

Plastic optical fiber 980/1000 µm

Design of FO core

-

-

Design of FO cable

-

-

Outer diameter

  • of optical fiber

980 µm

980 µm

  • of optical fiber sheath

1 000 µm

1 000 µm

  • of FO core sheath

2.2 mm

2.2 mm

  • of cable

7.8 mm

8 mm

Symmetrical deviation

  • of outer diameter of FO core sheath

0.1 mm

0.1 mm

  • of outer diameter of cable

-

-

Width of cable sheath

-

-

Symmetrical tolerance of cable sheath width

-

-

Thickness of cable sheath

-

-

Symmetrical tolerance of cable sheath thickness

-

-

Material

  • of optical fiber core

Polymethylmethacrylate (PMMA)

Polymethylmethacrylate (PMMA)

  • of optical fiber sheath

Fluoridated special polymer

Fluoridated special polymer

  • of FO core sheath

PA

PA

  • of FO cable sheath

PVC

PUR

  • of the strain relief

Kevlar fibers

Kevlar fibers

Color

  • of FO core sheath

Orange/black

Orange/black

  • of cable sheath

Green

Green

Bending radius

  • Minimum permitted single bending radius

100 mm

60 mm

  • Minimum permitted repeated bending radius

150 mm

60 mm

  • With continuous bending

-

0.04 m

Number of bending cycles

-

5 000 000

Maximum tensile load

100 N

100 N

Short-term lateral force per length

100 N/cm

200 N/cm

Continuous lateral force per length

-

20 N/cm

Weight per length

65 kg/km

55 kg/km

Permitted ambient conditions

Ambient temperature

  • During operation

-30 … +70 °C

-20 … +70 °C

  • During storage

-30 … +70 °C

-40 … +80 °C

  • During transport

-30 … +70 °C

-40 … +80 °C

  • During mounting

0 … 50 °C

5 … 50 °C

Ambient conditions for operation

-

-

IP degree of protection

-

-

Behavior in fire

Flame-retardant in accordance with IEC 60332-1-2

Flame-retardant in accordance with IEC 60332-1-2

Chemical resistance

  • Mineral oil

Limited resistance

Resistant

  • Grease

Limited resistance

Resistant

  • Water

-

-

Radiological resistance against UV radiation

Not resistant

Resistant

Product properties, functions, componentsGeneral

Product property

  • Halogen-free

No

No

  • Silicon-free

Yes

Yes

Product component: protection against rodents

No

No

Cable length with plastic optical fiber

  • Maximum with Industrial Ethernet

50 m

50 m

  • Maximum with PROFIBUS

-

-

Standards, specifications, approvals

Certificate of suitability

UL approval: OFN (NEC Article 770, UL 1651) / CSA approval: OFN (CSA standard C22.2 No232-M1988)

UL-758 AWM Style 5422

  • RoHS compliance

Yes

Yes


Order No.

6XV1 861-2A

6XV1 861-2C

6XV1 861-2D

Product type designation

PCF Standard Cable GP

PCF Trailing Cable

PCF Trailing Cable GP

Product description

Polymer cladded fiber cable, sold by the meter, non-assembled

Polymer cladded fiber cable, sold by the meter, non-assembled

Polymer cladded fiber cable, sold by the meter, non-assembled

Suitability for application

Cable for fixed installation for indoor and outdoor use, UL approval

Cable for use with high mechanical stress and moving applications (e.g. trailing cables), without UL approval

Cable for use with high mechanical stress and moving applications (e.g. trailing cables), UL approval

Design of preassembled FO cable

Can be fitted with SC RJ, SC RJ Plug PRO, BFOC and Simplex connectors

Can be fitted with SC RJ, SC RJ Plug PRO, BFOC and Simplex connectors

Can be fitted with SC RJ, SC RJ Plug PRO, BFOC and Simplex connectors

Cable designation

AT-V(ZN)YY 2K 200/230

AT-V(ZN)Y(ZN)11Y 2K 200/230

AT-V(ZN)Y(ZN)Y 2K 200/230

Cable length

-

-

-

Optical data

Maximum damping factor per length at 660 nm

10 dB/km

10 dB/km

10 dB/km

Bandwidth length product at 650 nm

17 GHz·m

17 GHz·m

17 GHz·m

Mechanical data

Number of fibers per FO core

1

1

1

Number of FO cores per FO cable

2

2

2

Design of FO fiber

Step index fiber 200/230 µm

Step index fiber 200/230 µm

Step index fiber 200/230 µm

Design of FO core

-

-

-

Design of FO cable

-

-

-

Outer diameter

  • of optical fiber

200 µm

200 µm

200 µm

  • of optical fiber sheath

230 µm

230 µm

230 µm

  • of FO core sheath

2.2 mm

2.2 mm

2.2 mm

  • of cable

7.2 mm

8.8 mm

8.8 mm

Symmetrical deviation

  • of outer diameter of FO core sheath

0.1 mm

0.1 mm

0.1 mm

  • of outer diameter of cable

0.5 mm

0.5 mm

0.5 mm

Width of cable sheath

-

-

-

Symmetrical tolerance of cable sheath width

-

-

-

Thickness of cable sheath

-

-

-

Symmetrical tolerance of cable sheath thickness

-

-

-

Material

  • of optical fiber core

Quartz glass

Quartz glass

Quartz glass

  • of optical fiber sheath

Special polymer

Special polymer

Special polymer

  • of FO core sheath

PVC

PVC

PVC

  • of FO cable sheath

PVC

PUR

PVC

  • of the strain relief

Aramide fibers

Aramide fibers

Aramide fibers

Color

  • of FO core sheath

Orange/black

Orange/black

Orange/black

  • of cable sheath

Green

Green

Green

Bending radius

  • Minimum permitted single bending radius

70 mm

130 mm

130 mm

  • Minimum permitted repeated bending radius

105 mm

175 mm

175 mm

  • With continuous bending

-

-

-

Number of bending cycles

-

5 000 000

5 000 000

Maximum tensile load

100 N

800 N

800 N

Short-term lateral force per length

500 N/cm

500 N/cm

500 N/cm

Continuous lateral force per length

300 N/cm

300 N/cm

300 N/cm

Weight per length

45 kg/km

85 kg/km

85 kg/km

Permitted ambient conditions

Ambient temperature

  • During operation

-40 … +90 °C

-25 … +75 °C

-25 … +75 °C

  • During storage

-40 … +90 °C

-30 … +75 °C

-30 … +75 °C

  • During transport

-40 … +90 °C

-30 … +75 °C

-30 … +75 °C

  • During mounting

-5 … +50 °C

-5 … +50 °C

-5 … +50 °C

Ambient conditions for operation

-

-

-

IP degree of protection

-

-

-

Behavior in fire

Flame-retardant in accordance with IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)

Flame-retardant

Flame-retardant in accordance with IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)

Chemical resistance

  • Mineral oil

Limited resistance

Resistant

Limited resistance

  • Grease

Limited resistance

Resistant

Limited resistance

  • Water

-

-

-

Radiological resistance against UV radiation

Resistant

Resistant

Resistant

Product properties, functions, componentsGeneral

Product property

  • Halogen-free

No

No

No

  • Silicon-free

Yes

Yes

Yes

Product component: protection against rodents

No

No

No

Cable length with polymer cladded fiber

  • Maximum with Industrial Ethernet

100 m

100 m

100 m

  • Maximum with PROFIBUS

400 m

400 m

400 m

Standards, specifications, approvals

Certificate of suitability

UL approval: OFN (NEC Article 770, UL 1651) / CSA approval: OFN 90 Cel, FT1, FT4 (CSA standard C22.2 No232-M1988)

-

UL approval: OFN (NEC Article 770, UL 1651) / CSA approval: OFN 90 Cel, FT1, FT4 (CSA standard C22.2 No232-M1988)

  • RoHS compliance

Yes

Yes

Yes
























































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET ECOFAST Введение Industrial Ethernet Введение Передача данных Обзор коммуникаций Топологии Критерии выбора типа сети Сетевые компоненты для Industrial Ethernet Обзор пассивных сетевых компонент Обзор по кабелям "витая пара" Технология FastConnect для Industrial Ethernet Штекер IE FC RJ45 Штекер IE FC RJ45 4 x 2 Штекеры IE Push Pull Plug PRO IE Соединительный кабель M12-180/M12-180 IE FC TP кабель 2 х 2 IE FC TP кабель 4 x 2 Гибридный кабель IE Цепи питания TP Cord Соединительные кабели IE M12-180/M12-180 Розетка RJ45 для Industrial Ethernet Модульный соединитель IE FC RJ45 Монтажный кабель ITP Обзор FC FOC оптических кабелей Стеклянные волоконно-оптические кабели быстрого монтажа FC FO монтажный комплект Оптические кабели Стеклянный волоконно-оптический кабель Оптические POF и PCF кабели Комплект для монтажа соединителей на POF/PCF FOC оптические кабели Industrial Ethernet коммутаторы Активные сетевые компоненты Безопасность передачи данных в промышленных сетях Системные интерфейсы Аксессуары Управление сетью Сетевые переходы Решения партнеров PROFINET PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366
Яндекс.Метрика