Order No. |
6XV1 812-8A |
6XV1 830-8AH10 |
Product type designation |
Energy Cable 2 x 0.75 |
Energy Cable 5 x 1.5 |
Product description |
Energy cable (2-core), sold by the meter, in bulk |
Energy cable (5-core), sold by the meter, in bulk |
Suitability for application |
Connection of signaling contact and 24 V power supply to SCALANCE X and SCALANCE W |
Power supply of ET 200 modules with 7/8" power interface |
Cable designation |
L-YY-2x1x0.75 GR |
L-Y11Y-Z 5x1x1.5 GR |
Cable length |
- |
- |
Electrical specifications |
||
Operating voltage, rms value |
600 V |
600 V |
Conductor cross-section of power core |
0.75 mm |
1.5 mm |
Continuous current of power cores |
6 A |
16 A |
Mechanical data |
||
Number of electrical cores |
2 |
5 |
Design of shield |
- |
- |
Design of electrical connection FastConnect |
- |
No |
Outer diameter |
||
|
1.3 mm |
1.55 mm |
|
2.5 mm |
2.73 mm |
|
7.4 mm |
10.5 mm |
Symmetrical tolerance of outer diameter of cable sheath |
0.3 mm |
0.3 mm |
Outer diameter of cable sheath - Note |
- |
- |
Material |
||
|
PVC |
PVC |
|
PVC |
PUR |
|
- |
- |
Color |
||
|
Brown / blue |
Black |
|
Gray |
Gray |
Bending radius |
||
|
19 mm |
27 mm |
|
45 mm |
63 mm |
|
- |
- |
Number of bending cycles |
- |
- |
|
- |
- |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
- |
Maximum tensile load |
100 N |
500 N |
Weight per length |
70 kg/km |
149 kg/km |
Permissible ambient conditions |
||
Ambient temperature |
||
|
-20 … +80 °C |
-40 … +80 °C |
|
-20 … +80 °C |
-40 … +80 °C |
|
-20 … +80 °C |
-40 … +80 °C |
|
-20 … +80 °C |
-40 … +80 °C |
|
- |
- |
Ambient conditions for operation |
- |
- |
IP degree of protection |
- |
- |
Behavior in fire |
Flame-retardant in accordance with IEC 60332-1 |
Flame-retardant in accordance with IEC 60332-1 |
Chemical resistance |
||
|
Limited resistance |
Resistant |
|
Limited resistance |
Resistant |
|
- |
- |
Radiological resistance against UV radiation |
Resistant |
Resistant |
Product properties, functions, components General |
||
Product property |
||
|
No |
No |
|
Yes |
Yes |
Standards, specifications, approvals |
||
UL-Listing at 300 V rating |
Yes: CL3 |
No |
UL-Style at 600 V rating |
Yes |
Yes |
Certificate of suitability |
- |
- |
|
Yes |
Yes |
Order No. |
6XV1 801-5DH10 |
Product type designation |
POWER CONNECTING CABLE M12-180/M12-180 |
Product description |
Flexible connecting cable (4-core), preferred length, preassembled with a 4-pin M12 plug and a 4-pin M12 socket (A-coded) |
Suitability for application |
Cable for connecting the 24 V power supply to ET 200eco PN with IP 65/67 protection |
Cable designation |
LI9YH-Y 4x0.75 |
Cable length |
1 m |
Electrical specifications |
|
Operating voltage, rms value |
300 V |
Conductor cross-section of power core |
0.75 mm |
Continuous current of power cores |
- |
Mechanical data |
|
Number of electrical cores |
4 |
Design of shield |
- |
Design of electrical connection FastConnect |
- |
Outer diameter |
|
|
1.1 mm |
|
1.7 mm |
|
5.7 mm |
Outer diameter of cable sheath - Note |
- |
Symmetrical tolerance of outer diameter of cable sheath |
0.2 mm |
Material |
|
|
PP |
|
PVC |
|
- |
Color |
|
|
Brown / white / blue / black |
|
Gray |
Bending radius |
|
|
57 mm |
|
57 mm |
|
- |
Number of bending cycles |
- |
|
- |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
Maximum tensile load |
15 N |
Weight per length |
54 kg/km |
Permissible ambient conditions |
|
Ambient temperature |
|
|
-25 … +80 °C |
|
-25 … +80 °C |
|
-25 … +80 °C |
|
- … 80 °C |
|
With moving applications, an operating temperature of -5 to +80 °C is permitted |
Ambient conditions for operation |
- |
IP degree of protection |
IP65/67 |
Behavior in fire |
Flame-retardant in accordance with UL 758 (CSA FT 1) |
Chemical resistance |
|
|
Limited resistance |
|
Limited resistance |
|
- |
Radiological resistance to UV radiation |
Not resistant |
Product properties, functions, components General |
|
Product property |
|
|
No |
|
Yes |
Standards, specifications, approvals |
|
UL listing at 300 V rating |
- |
UL-Style at 600 V rating |
- |
Certificate of suitability |
UL approval |
|
Yes |
Order No. |
6GK1 905-0FA00 |
6GK1 905-0FB00 |
6GK1 905-0FC00 |
Product type designation |
7/8" connector |
7/8" connector |
7/8" Power T-Tap PRO |
Product description |
7/8" connector with pin insert, 5-pin |
7/8" connector with female contact insert, 5-pin |
Energy T-piece with two 7/8" female contact inserts and one 7/8" pin insert, each 5-pin |
Suitability for application |
For field assembly for ET200 |
For field assembly for ET200 |
For energy connection and energy distribution to ET200pro modules |
Transmission rate |
|||
Transmission rate with PROFIBUS |
- - |
- - |
- - |
Interfaces |
|||
Maximum number of electrical connections for network components or terminal equipment |
1 |
1 |
3 |
Number of electrical connections for network components or terminals |
7/8" connector (pin insert) |
7/8" connector (female contact insert) |
7/8" connector (2 x female contact insert, 1 x pin insert) |
Mechanical data |
|||
Enclosure material |
Metal |
Metal |
Metal |
Design, dimensions and weights |
|||
Type of cable outlet |
180 degree cable outlet |
180 degree cable outlet |
- |
Width |
27 mm |
27 mm |
58.5 mm |
Height |
27 mm |
27 mm |
73.5 mm |
Depth |
83 mm |
83 mm |
26.5 mm |
Net weight |
50 g |
50 g |
112 g |
Permissible ambient conditions |
|||
Ambient temperature |
|||
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operation, maximum |
- |
- |
- |
IP degree of protection |
IP65/67 |
IP65/67 |
IP65/67 |
Chemical resistance to water |
Resistant |
Resistant |
Resistant |
Product properties, functions, components General |
|||
Product property silicon-free |
Yes |
Yes |
Yes |
Product component strain relief |
Yes |
Yes |
Yes |
Standards, specifications, approvals |
|||
Certificate of suitability: RoHS conformity |
Yes |
Yes |
Yes |
Order No. |
6GK1 908-0DC10-6AA3 |
6GK1 907-0DC10-6AA3 |
6GK1 907-0DB10-6AA3 |
Product type designation |
Signaling Contact M12 Cable Connector |
Power M12 Cable Connector PRO |
Power M12 Plug PRO |
Product description |
M12 connecting socket for signal contact, 5-pin, B-coded |
M12 Power connecting socket, 4-pin, A-coded |
M12 Power connector, 4-pin, A-coded |
Suitability for application |
For connection to SCALANCE X208PRO for signal contact |
For connection to SCALANCE W-700 / X208PRO for 24 V DC power supply |
For connection to PS791-1PRO power supply for 24 V DC power supply |
Transmission rate |
|||
Transmission rate with PROFIBUS |
- - |
- - |
- - |
Interfaces |
|||
Maximum number of electrical connections for network components or terminal equipment |
1 |
1 |
1 |
Number of electrical connections for network components or terminals |
M12 connector (B-coded, 5-pin) |
M12 connector (female contact insert, A-coded, 4-pin) |
M12 connector (pin insert, A-coded, 4-pin) |
Mechanical data |
|||
Enclosure material |
Plastic |
Plastic |
Plastic |
Design, dimensions and weights |
|||
Type of cable outlet |
180 degree cable outlet |
180 degree cable outlet |
180 degree cable outlet |
Width |
14 mm |
19 mm |
19 mm |
Height |
14 mm |
19 mm |
19 mm |
Depth |
59 mm |
73 mm |
73 mm |
Net weight |
37 g |
40 g |
40 g |
Permissible ambient conditions |
|||
Ambient temperature |
|||
|
-40 … +70 °C |
-40 … +70 °C |
-40 … +70 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
|
-40 … +80 °C |
-40 … +80 °C |
-40 … +80 °C |
Relative humidity at 25 °C without condensation during operation, maximum |
- |
- |
- |
IP degree of protection |
IP65/67 |
IP65/67 |
IP65/67 |
Chemical resistance to water |
Resistant |
Resistant |
Resistant |
Product properties, functions, components General |
|||
Product property silicon-free |
Yes |
Yes |
Yes |
Product component strain relief |
Yes |
Yes |
Yes |
Standards, specifications, approvals |
|||
Certificate of suitability: RoHS conformity |
Yes |
Yes |
Yes |