MicroSAM |
|
Design, enclosure |
|
Weight |
15 kg |
Degree of protection |
IP65 (NEMA 4X) |
Mounting |
|
Installation on |
Post, pipe or wall |
Distance from wall or next chromatograph |
300 mm (12") |
Distance from ceiling or floor |
200 mm (8") |
Explosion protection |
ATEX II 2 G Ex d IIC T4 Gb DMT 03 ATEX E 069 X IEC Ex BVS 10.0004X CSA Class I, Div 1, Groups B, C, D T4 |
Support bracket |
|
|
380 x 110 mm |
|
8 |
|
146 x 110 mm |
Electrical characteristics |
|
Power supply |
24 V DC (18.5 ... 30.2 V) |
Power consumption |
|
|
18 W |
|
60 W |
|
IEC 61010 / DIN VDE 0411 |
EMC immunity |
According to IEC 60801/DIN VDE 0843 |
|
|
|
2 kV |
|
1 kV |
|
2 kV |
|
|
|
1 kV |
|
|
|
8 kV |
|
|
|
10 V/m |
|
According to CISPR 11 / EN 55011 / DIN VDE 0875 Limit class B |
|
T2.5 A |
Gas inlet conditions |
|
Permissible sample pressure |
10 … 50 kPa |
Sample flow |
20 … 100 ml/min |
Max. sample temperature |
120 °C |
Solid components |
< 0.1 mm |
Climatic conditions |
|
Permissible ambient temperature |
- 20 ... 50 °C (depending on oven temperature) |
Permissible storage/transport temperature |
- 30 ... 70 °C |
Permissible relative humidity |
Max. 90% |
Sample and injection |
|
Sample streams |
3 |
Calibration sample streams |
1 |
Phase |
Gaseous |
Required filtration |
Degree of separation 99.99 % for < 0.1 m particles |
Material with which the sample comes into contact |
Stainless steel, fused silica, polyimide |
Injection |
"Valveless" live injection |
|
With multifunctional diaphragm valve |
|
2 ... 50 µl |
|
165 °C |
Oven |
|
Number/type |
1/isothermal |
Purging with N2 |
Possible |
Dimensions (DxH) |
160 x 10 mm |
Heating capacity |
20 W |
Temperature range |
60 … 155 °C |
Temperature stability |
± 0.1 K (60 ... 155 °C) |
Temperature accuracy |
± 3 K (60 ... 155 °C) |
Retention time variations per 10 °C change in ambient temperature |
Approx. 0.3% |
Heating-up period from 30 ... 100 °C |
10 minutes |
Columns and gases |
|
Column type |
Capillary columns 0.15 ... 0.25 mm/internal |
Separating column switching |
Multidimensional chromatography with backflushing and cut in live system |
Multifunctional diaphragm valve |
For injection and backflushing |
Gas connections |
Swagelok 1/8" |
Pressure regulators |
Max. 4 single-channel electronic pressure regulators |
Solenoid valves for control of diaphragm valve |
2 NC contacts, 2 NO contacts |
Carrier gas |
H2, N2, He, Ar |
|
> 99,999 % (5.0) |
|
< 0.1 m |
|
Degree of separation 99.99% for < 0.1 m particles |
|
10 ... 60 ml/min |
|
500 … 700 kPa |
Instrument air |
Not required |
Detectors, calibration and performance data |
|
Detector type |
TCD, max. 8 sensors |
Ambient temperature |
Negligible |
Vibrations |
Negligible |
Cell volume |
0.02 l |
Calibration |
Manual or automatic, single-level or multi-level |
Smallest measuring range |
1 000 ppm (application-dependent) |
Linear range |
Typically > 104 |
Cycle time |
Typically 30 … 240 s |
Electrical inputs and outputs |
|
Basic equipment |
|
|
4, freely usable (expandable by NAU or I/O Extender, see communication in "General information") |
|
4, 3 freely usable (expandable by NAU or I/O Extender, see communication in "General information") |
Interfaces |
|
|
1 x Ethernet 10BaseT / TCP/IP |
|
1 x RS 485 or RS 232 / Modbus RTU, OPC (ODPC) over Ethernet |
Electronics |
|
Communication and analytical controller (CAC) |
|
|
Intel 586 architecture |
|
128 MB |
|
64 MB |
|
Windows CE 5.0 |
|
Preinstalled. Modifications or upgrades for operation PC downloadable via network or locally |
Realtime signal processor (RSP) |
|
|
Motorola 68376, 20 MHz |
|
1 MB |
|
1 MB |
|
Forth |
|
Preinstalled. Modifications or upgrades downloadable via internal service interface |
Controller |
|
|
3 |
|
1 |
|
|
|
|
Recommended operator panel |
|
|
Desktop or laptop |
|
At least Pentium III |
|
800 MHz |
|
1 x Ethernet |
|
Windows ME, 2000 or XP |
|
|