General information |
|
Measuring ranges |
4, internally and externally switchable; manual and autoranging possible |
Smallest possible measuring span |
0 ... 10 vpm |
Largest possible measuring span |
99.999 vpm*) |
Concentration units |
ppm, C1, C3, C6 or mgC/m3 |
Autoranging |
Hysteresis, selectable |
Measured-value display |
Digital concentration display (5 digits with floating point) |
Resolution of digital display |
0.1 % of measured value |
Operating position |
Front wall, vertical |
Conformity |
CE mark in accordance with EN 50081-1, EN 50082-2 |
Oven temperature |
Adjustable, 100 ... 200 °C |
Design, enclosure |
|
Degree of protection |
IP20 according to EN 60529 |
Weight |
Approx. 23 kg |
Electrical characteristics |
|
Power supply |
100 ... 120 V AC (nominal range of use 90 ... 132 V), 48 ... 63 Hz or 200 ... 240 V AC (nominal range of use 180 ... 264 V), 48 ... 63 Hz |
Power consumption |
|
EMC (ElectromagneticCompatibility) |
In accordance with standard requirements of NAMUR NE21 (08/98) |
Electrical safety |
In accordance with EN 61010-1, overvoltage category II |
Fuse values |
|
Gas inlet conditions |
|
Permissible sample gas pressure |
|
|
< 2 000 hPa abs. |
|
600 ... 1 100 hPa |
Sample gas flow |
18 ... 60 l/h (0.3 ... 1 l/min) |
Sample gas temperature |
0 ... 200 °C |
Sample gas humidity |
< 90% RH (RH: relative humidity) |
Dynamic response |
|
Warm-up period |
At room temperature, approx. 2 ... 3 h |
Delayed display (T90) |
2 ... 3 s |
Damping (electrical time constant) |
0 ... 100 s, parameterizable |
Dead time (purging time of the gas path in the unit at 1 l/min) |
With filter, 2 ... 3 s |
Time for device-internal signal processing |
< 1 s |
Measuring response (relating to sample gas pressure 1 013 hPa absolute, 0.5 l/min sample gas flow and 25 °C ambient temperature) |
|
Output signal fluctuation |
< 0.75% of the smallest possible measuring range according to rating plate, with electronic damping constant of 1 s (corresponds to ± 0.25% at 2 ) |
Zero point drift |
< 0.5%/month of the smallest possible measuring span according to rating plate |
Measured-value drift |
< 1%/week of the current measuring range |
Repeatability |
< 1% of the current measuring range |
Detection limit |
0.1 ppm (version for ultra-pure gas measurement: 50 ppb) |
Linearity error |
< 1% of the current measuring range |
Influencing variables (relating to sample gas pressure 1 013 hPa absolute, 0.5 l/min sample gas flow and 25 °C ambient temperature) |
|
Ambient temperature |
< 1%/10 K referred to smallest possible span according to rating plate |
Atmospheric pressure |
< 1%/50 hPa |
Sample gas pressure |
< 2% of the current measuring range range/1% pressure change (within 600 ... 1 100 hPa) |
Power supply |
< 1% of the current measuring range with rated voltage ± 10% |
Position influence |
< 1 % with < 15° inclination |
Electrical inputs and outputs |
|
Analog output |
0/2/4 ... 20 mA, isolated; max. load 750 |
Relay outputs |
6, with changeover contacts, freely parameterizable, e.g. for measuring range identification; load: 24 V AC/DC/1 A, potential-free |
Analog inputs |
2, dimensioned for 0/2/4 to 20 mA for external pressure sensor and correction of influence of accompanying gas (correction of cross-interference) |
Binary inputs |
6, designed for 24 V, floating, freely parameterizable, e.g. for measuring range switchover |
Serial interface |
RS 485 |
Options |
AUTOCAL function with 8 additional binary inputs and relay outputs each, also with PROFIBUS PA or PROFIBUS DP |
Climatic conditions |
|
Permissible ambient temperature |
5 ... 45 °C during operation, -30 ... +70 °C during storage and transportation |
Permissible humidity |
< 90% RH (RH: relative humidity) as annual average, during storage and transportation (must not fall below dew point) |
*) 100 % as special application
FIDAMAT 6 with pump and heated oven, with combustion air connection |
|||||
---|---|---|---|---|---|
Gases |
Operating pressure |
||||
Inlet pressure |
Pump startup |
Flow through FID |
Flow through bypass |
||
Without |
With |
||||
hPa (abs.) |
hPa (abs.) |
hPa (abs.) |
ml/min |
ml/min |
|
Combustion gas |
3 000 ... 5 000 |
2 000 ± 20 |
~ 25 |
— |
|
Combustion air |
3 000 ... 5 000 |
1 420 ± 20 |
1 500 |
~ 320 |
~ 500 |
Sample gas |
~ 1000 |
— |
1 500 ± 2 |
~ 3 |
~ 1 000 |
Zero gas |
3 500 ... 4 000 |
— |
1 500 ± 2 |
~ 3 |
~ 1 000 |
Calibration gas |
3 500 ... 4 000 |
— |
1 500 ± 2 |
~ 3 |
~ 1 000 |
FIDAMAT 6 without pump, with heated oven, with combustion air connection |
|||||
---|---|---|---|---|---|
Gases |
Operating pressure |
||||
Inlet pressure |
Sample/calibration gas |
Flow through FID |
Flow through bypass |
||
Without |
With |
||||
hPa (abs.) |
hPa (abs.) |
hPa (abs.) |
ml/min |
ml/min |
|
Combustion gas |
3 000 ... 5 000 |
2 000 ± 20 |
~ 25 |
— |
|
Combustion air |
3 000 ... 5 000 |
1 480 ± 5 |
— |
~ 320 |
~ 300 |
Sample gas |
1 500 ... 2 000 |
— |
1 500 ± 2 |
~ 3 |
~ 500 |
Zero gas |
1 500 ... 2 000 |
— |
1 500 ± 2 |
~ 3 |
~ 500 |
Calibration gas |
1 500 ... 2 000 |
— |
1 500 ± 2 |
~ 3 |
~ 500 |
The supply gases (combustion gas, combustion air) must have a degree of purity of 5.0 in order to guarantee correct measurements. The degree of purity must be increased in the case of very small hydrocarbon concentrations (< 1 ppm).