Order No. |
6XV1 840-2AH10 |
6XV1 870-2B |
6XV1 870-2F |
Product type designation |
IE FC TP Standard Cable GP 2 x 2 (Type A) |
IE FC TP Flexible Cable GP 2 x 2 (Type B) |
IE TP Torsion Cable 2 x 2 (Type C) |
Product description |
Standard bus cable (4-core), sold by the meter, in bulk |
Flexible bus cable (4-core), sold by the meter, in bulk |
Highly flexible bus cable (4-core), sold by the meter, in bulk |
Suitability for application |
Standard cable with rigid cores for quick installation |
For occasionally moved machine components |
Continuous movement when using with robots |
Cable designation |
2YY (ST) CY 2x2x0.64/1.5-100 GN |
2YY (ST) CY 2x2x0.75/1.5-100 LI GN |
02YS C11Y 1x4x0.75/1.5-100 LI VZN FRNC GN |
Cable length |
- |
- |
- |
Electrical specifications |
|||
Attenuation factor per length |
|||
|
52 dB/km |
60 dB/km |
81 dB/km |
|
195 dB/km |
210 dB/km |
410 dB/km |
Characteristic impedance at 1 MHz to 100 MHz |
100 |
100 |
100 |
Relative symmetrical tolerance of characteristic impedance at 1 MHz to 100 MHz |
15 % |
15 % |
15 % |
Near-end crosstalk per length at 1 MHz to 100 MHz |
- |
500 dB/km |
500 dB/km |
Surface transfer resistance at 10 MHz |
10 m /m |
20 m /m |
100 m /m |
Loop resistance per length |
115 /km |
120 /km |
120 /km |
Insulation resistance coefficient |
- |
- |
- |
Operating voltage, maximum |
- |
- |
- |
Mechanical data |
|||
Number of electrical cores |
4 |
4 |
4 |
Design of shield |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Design of electrical connection FastConnect |
Yes |
Yes |
No |
AWG number |
|||
Diameter of AWG22 core |
0.64 mm |
0.75 mm |
0.76 mm |
Outer diameter |
|||
|
0.64 mm |
0.75 mm |
0.76 mm |
|
1.5 mm |
1.5 mm |
1.5 mm |
|
3.9 mm |
3.9 mm |
- |
|
6.5 mm |
6.5 mm |
6.5 mm |
Symmetrical tolerance of outer diameter of cable sheath |
0.2 mm |
0.2 mm |
0.2 mm |
Outer diameter of cable sheath - Note |
- |
- |
- |
Material |
|||
|
PE |
PE |
PE |
|
PVC |
PVC |
- |
|
PVC |
PVC |
PUR |
|
- |
- |
- |
Color |
|||
|
white / yellow / blue / orange |
white / yellow / blue / orange |
white / yellow / blue / orange |
|
Green |
Green |
Green |
Bending radius |
|||
|
19.5 mm |
32.5 mm |
32.5 mm |
|
49 mm |
52 mm |
65 mm |
|
- |
- |
- |
Number of bending cycles |
- |
- |
- |
|
- |
- |
Not suitable for festoon mounting |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
- |
5 000 000 |
Maximum tensile load |
150 N |
150 N |
130 N |
Weight per length |
67 kg/km |
68 kg/km |
54 kg/km |
Permitted ambient conditions |
|||
Ambient temperature |
|||
|
-40 … +75 °C |
-25 … +75 °C |
-40 … +80 °C |
|
-40 … +75 °C |
-25 … +75 °C |
-40 … +80 °C |
|
-40 … +75 °C |
-25 … +75 °C |
-40 … +80 °C |
|
-20 … +60 °C |
-10 … +60 °C |
-20 … +60 °C |
Ambient conditions for operation |
- |
- |
- |
IP degree of protection |
- |
- |
- |
Behavior in fire |
Flame-retardant in accordance with UL 1685 (CSA FT 4) |
Flame-retardant in accordance with UL 1685 (CSA FT 4) |
Flame-retardant in accordance with IEC 60332-1-2 |
Chemical resistance |
|||
|
Limited resistance |
Limited resistance |
resistant |
|
Limited resistance |
Limited resistance |
resistant |
|
- |
- |
- |
Radiological resistance to UV radiation |
resistant |
resistant |
resistant |
Product properties, functions, components General |
|||
Product property |
|||
|
No |
No |
Yes |
|
Yes |
Yes |
Yes |
Cable length for 100BaseTX with Industrial Ethernet |
100 m |
85 m |
55 m |
Standards, specifications, approvals |
|||
UL-Listing at 300 V rating |
Yes: CM / CMG / PLTC / Sun Res |
Yes: CM / CMG / PLTC / Sun Res |
Yes: UL Style 21161 |
UL-Style at 600 V rating |
Yes |
No |
No |
Certificate of suitability |
- |
- |
- |
|
Yes |
Yes |
- |
Standard for structured cabling |
Cat5e |
Cat5e |
Cat5e |
Marine classification association |
|||
|
No |
No |
No |
|
No |
No |
No |
|
No |
No |
No |
|
No |
No |
No |
|
No |
No |
No |
Order No. |
6XV1 870-2D |
6XV1 840-3AH10 |
6XV1 871-2S |
Product type designation |
IE FC TP Trailing Cable GP 2 x 2 (Type C) |
IE FC TP Trailing Cable 2 x 2 (Type C) |
IE FC TP Festoon Cable GP 2 x 2 (Type B) |
Product description |
Highly flexible bus cable (4-core), sold by the meter, in bulk |
Highly flexible bus cable (4-core), sold by the meter, in bulk |
Flexible bus cable (4-core), sold by the meter, in bulk |
Suitability for application |
Continuous movement in a trailing cable |
Continuous movement in a trailing cable |
For continuous movement in a trailing cable, festoon mounting |
Cable designation |
2YY (ST) CY 2x2x0.75/1.5-100 LI GN |
2YH (ST) C11Y 2x2x0.75/1.5-100 LI GN VZN FRNC |
2YY (ST) CY 2x2x0.75/1.5 LI GN |
Cable length |
- |
- |
- |
Electrical specifications |
|||
Attenuation factor per length |
|||
|
63 dB/km |
60 dB/km |
63 dB/km |
|
213 dB/km |
220 dB/km |
213 dB/km |
Characteristic impedance at 1 MHz ... 100 MHz |
100 |
100 |
100 |
Relative symmetrical tolerance of characteristic impedance at 1 MHz to 100 MHz |
5 % |
15 % |
5 % |
Near-end crosstalk per length at 1 MHz to 100 MHz |
500 dB/km |
- |
500 dB/km |
Surface transfer resistance at 10 MHz |
20 m /m |
10 m /m |
0.1 /m |
Loop resistance per length |
0.12 /m |
0.12 /m |
0.12 /m |
Insulation resistance coefficient |
- |
- |
- |
Operating voltage, maximum |
- |
- |
- |
Mechanical data |
|||
Number of electrical cores |
4 |
4 |
4 |
Design of shield |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Design of electrical connection FastConnect |
Yes |
Yes |
Yes |
AWG number |
|||
Diameter of AWG22 core |
0.75 mm |
0.75 mm |
0.75 mm |
Outer diameter |
|||
|
0.75 mm |
0.75 mm |
0.75 mm |
|
1.5 mm |
1.5 mm |
1.5 mm |
|
3.9 mm |
3.9 mm |
3.9 mm |
|
6.5 mm |
6.5 mm |
6.5 mm |
Symmetrical tolerance of outer diameter of cable sheath |
0.2 mm |
0.2 mm |
0.2 mm |
Outer diameter of cable sheath - Note |
- |
- |
- |
Material |
|||
|
PE |
PE |
PE |
|
PVC |
FRNC |
PVC |
|
PVC |
PUR |
PVC |
|
- |
- |
- |
Color |
|||
|
white / yellow / blue / orange |
white / yellow / blue / orange |
white / yellow / blue / orange |
|
Green |
Green |
Green |
Bending radius |
|||
|
32.5 mm |
19.5 mm |
30 mm |
|
49 mm |
49 mm |
70 mm |
|
100 mm |
100 mm |
- |
Number of bending cycles |
3 000 000 |
4 000 000 |
5 000 000 |
|
Suitable as trailing cable for 3 million bending cycles with a bending radius of 100 mm, a speed of 4 m/s, and an acceleration of 4 m/s . |
Suitable as trailing cable for 4 million bending cycles with a bending radius of 100 mm. |
5 million bending cycles with a bending radius of 70 mm, and an acceleration of 4 m/s . |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
- |
- |
Maximum tensile load |
150 N |
150 N |
150 N |
Weight per length |
68 kg/km |
63 kg/km |
68 kg/km |
Permitted ambient conditions |
|||
Ambient temperature |
|||
|
-25 … +75 °C |
-40 … +75 °C |
-40 … +75 °C |
|
-25 … +75 °C |
-50 … +75 °C |
-50 … +75 °C |
|
-25 … +75 °C |
-50 … +75 °C |
-50 … +75 °C |
|
-10 … +60 °C |
-20 … +60 °C |
-20 … +60 °C |
Ambient conditions for operation |
- |
- |
- |
IP degree of protection |
- |
- |
- |
Behavior in fire |
Flame-retardant in accordance with UL 1685 (CSA FT 4) |
Flame-retardant in accordance with IEC 60332-1-2 |
Flame-retardant in accordance with UL 1685 (CSA FT 4) |
Chemical resistance |
|||
|
Limited resistance |
resistant |
Limited resistance |
|
Limited resistance |
resistant |
Limited resistance |
|
- |
- |
- |
Radiological resistance to UV radiation |
resistant |
resistant |
resistant |
Product properties, functions, components General |
|||
Product property |
|||
|
No |
Yes |
No |
|
Yes |
Yes |
Yes |
Cable length for 100BaseTX with Industrial Ethernet |
85 m |
85 m |
85 m |
Standards, specifications, approvals |
|||
UL listing at 300 V rating |
Yes: CMG / PLTC / Sun Res |
Yes: CMX |
Yes: CMG / PLTC / Sun Res |
UL-Style at 600 V rating |
Yes |
No |
Yes |
Certificate of suitability |
- |
- |
- |
|
Yes |
Yes |
Yes |
Standard for structured cabling |
Cat5e |
Cat5e |
Cat5e |
Marine classification association |
|||
|
No |
No |
No |
|
No |
No |
No |
|
No |
No |
No |
|
No |
No |
No |
|
No |
No |
No |
Order No. |
6XV1 871-2F |
6XV1 871-2L |
6XV1 840-4AH10 |
Product type designation |
IE FC TP FRNC Cable GP 2 x 2 (Type B) |
IE FC TP Food Cable 2 x 2 (Type C) |
IE FC TP Marine Cable 2 x 2 (Type B) |
Product description |
Flexible, halogen-free bus cable (4-core), sold by the meter, in bulk |
Flexible bus cable (4-core), sold by the meter, in bulk |
Bus cable (4-core), sold by the meter, in bulk |
Suitability for application |
For occasionally moved machine components |
Food, beverages and tobacco industries |
For marine and offshore use |
Cable designation |
L-9YH (ST) CH 2x2x0.34/1.5-100 GN VZN FRNC |
2YH (ST) C2Y 2X2X0.75/1.5-100 LI |
L-9YH (ST) CH 2 x 2 x 0.34/1.5-100 GN VZN FRNC |
Cable length |
- |
- |
- |
Electrical specifications |
|||
Attenuation factor per length |
|||
|
60 dB/km |
63 dB/km |
60 dB/km |
|
220 dB/km |
213 dB/km |
220 dB/km |
Characteristic impedance at 1 MHz to 100 MHz |
100 |
100 |
100 |
Relative symmetrical tolerance of characteristic impedance at 1 MHz to 100 MHz |
15 % |
5 % |
15 % |
Near-end crosstalk per length at 1 MHz to 100 MHz |
500 dB/km |
500 dB/km |
- |
Surface transfer resistance at 10 MHz |
10 m /m |
10 m /m |
10 m /m |
Loop resistance per length |
120 /km |
120 /km |
120 /km |
Insulation resistance coefficient |
- |
- |
- |
Operating voltage, maximum |
- |
- |
- |
Mechanical data |
|||
Number of electrical cores |
4 |
4 |
4 |
Design of shield |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Overlapping aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Design of electrical connection FastConnect |
Yes |
Yes |
Yes |
AWG number |
|||
Diameter of AWG22 core |
0.75 mm |
0.75 mm |
0.75 mm |
Outer diameter |
|||
|
0.75 mm |
0.75 mm |
0.75 mm |
|
1.5 mm |
1.5 mm |
1.5 mm |
|
3.9 mm |
3.9 mm |
3.9 mm |
|
6.5 mm |
6.5 mm |
6.5 mm |
Symmetrical tolerance of outer diameter of cable sheath |
0.2 mm |
0.2 mm |
0.2 mm |
Outer diameter of cable sheath - Note |
- |
- |
- |
Material |
|||
|
PP |
PE |
PP |
|
FRNC |
FRNC |
FRNC |
|
FRNC |
PE |
FRNC |
|
- |
- |
- |
Color |
|||
|
white / yellow / blue / orange |
white / yellow / blue / orange |
white / yellow / blue / orange |
|
Green |
Black |
Green |
Bending radius |
|||
|
39 mm |
20 mm |
39 mm |
|
97.5 mm |
49 mm |
97.5 mm |
|
- |
- |
- |
Number of bending cycles |
- |
- |
- |
|
- |
- |
- |
Number of torsion cycles with torsion by ± 180° on 1 m cable length |
- |
- |
- |
Maximum tensile load |
150 N |
150 N |
150 N |
Weight per length |
68 kg/km |
55 kg/km |
68 kg/km |
Permitted ambient conditions |
|||
Ambient temperature |
|||
|
-25 … +70 °C |
-40 … +75 °C |
-25 … +70 °C |
|
-40 … +75 °C |
-50 … +75 °C |
-40 … +70 °C |
|
-40 … +75 °C |
-50 … +75 °C |
-40 … +70 °C |
|
0 … 50 °C |
-20 … +60 °C |
0 … 50 °C |
Ambient conditions for operation |
- |
- |
- |
IP degree of protection |
- |
- |
- |
Behavior in fire |
Flame-retardant in accordance with IEC 60332-3-22 (Category A/F) |
Flammable |
Flame-retardant in accordance with IEC 60332-3-22 (Category A/F) |
Chemical resistance |
|||
|
Limited resistance |
Limited resistance |
Limited resistance |
|
Limited resistance |
Limited resistance |
Limited resistance |
|
- |
- |
- |
Radiological resistance to UV radiation |
resistant |
resistant |
resistant |
Product properties, functions, components General |
|||
Product property |
|||
|
Yes |
Yes |
Yes |
|
Yes |
Yes |
Yes |
Cable length for 100BaseTX with Industrial Ethernet |
85 m |
85 m |
85 m |
Standards, specifications, approvals |
|||
UL listing at 300 V rating |
Yes: CMG / PLTC / Sun Res |
No |
No |
UL-Style at 600 V rating |
No |
No |
Yes: CM / CMG / PLTC / Sun Res |
Certificate of suitability |
- |
- |
- |
|
Yes |
Yes |
Yes |
Standard for structured cabling |
Cat5e |
Cat5e |
Cat5e |
Marine classification corporation |
|||
|
No |
No |
Yes |
|
No |
No |
Yes |
|
No |
No |
Yes |
|
No |
No |
Yes |
|
No |
No |
Yes |