Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2012
архивный
(4872) 700-366
skenergo@mail.ru
SCALANCE X-400 managed (Layer 3)

Order No.

6GK5 408-2FD00-2AA2

6GK5 414-3FC00-2AA2

Product type designation

SCALANCE X408-2

SCALANCE X414-3E

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

Transfer rate 3

1 000 Mbit/s

1 000 Mbit/s

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

12

26

Number of electrical connections for operator console

1

1

Design of electrical connection for operator console

RS232 port

RS232 port

Number of electrical connections

  • for network components and terminal equipment

8

14

  • for network components and terminal equipment with extender modules

-

8

  • for alarm contact

1

1

  • for media module

2

3

  • for power supply

1

1

  • for redundant power supply

1

1

Design of electrical connection

  • for network components and terminal equipment

RJ45 port (4 x 1GE, 4 x FE)

RJ45 port (2 x 1GE, 12 x FE)

  • for network components and terminal equipment with extender modules

-

RJ45 port via EM495-8

  • for signaling contact

4-pole terminal block

4-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

4

4

  • at 1000 Mbit/s

4

2

  • with extender modules

-

8

Design of optical interface for optical waveguide

  • at 100 Mbit/s

BFOC or SC ports via media modules MM491-2, MM491-2LD, MM491-2LH+

BFOC or SC ports via media modules MM491-2, MM491-2LD, MM491-2LH+

  • at 1000 Mbit/s

SC ports via media modules MM492-2, MM492-2LD, MM492-2LH, MM492-2LH+

SC ports via media modules MM492-2, MM492-2LD, MM492-2LH, MM492-2LH+

  • with extender modules

-

BFOC or SC ports via media modules MM491-2, MM491-2LD, MM491-2LH+, MM492-2, MM492-2LD, MM492-2LH, MM492-2LH+

Connectable optical power relative to 1 mW

  • of the transmitter output

- -

- -

  • of the receiver input maximum

-

-

Optical sensitivity relative to 1 mW of the receiver input minimum

-

-

Attenuation of fiber-optic cable transmission link minimum necessary

-

-

Range at the optical interface depending on the optical fiber used

- -

- -

Number of extender expansion interfaces

-

1

design of the extender extension interface

-

EM495-8 or EM496-4

design of the removable storage C-PLUG

Yes

Yes

Inputs/outputs

Operating current of signaling contacts at AC maximum

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

Number of digital inputs

-

2

Number of electrical connections for digital input signals

-

2

Design of electrical connection for digital input signals

-

5-pole terminal block

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

Supply voltage external

24 V

24 V

  • minimum

20.4 V

20.4 V

  • maximum

28.8 V

28.8 V

Product component fusing at power supply input

Yes

Yes

Type of fusing at input for supply voltage

Consumed current maximum

0.7 A

2 A

Active power loss

  • at 24 V for DC

8 W

15 W

  • maximum

48 W

48 W

Permitted ambient conditions

Ambient temperature

  • during operating

0 … 60 °C

-40 … +70 °C

  • during storage

-40 … +80 °C

-40 … +80 °C

  • during transport

-40 … +80 °C

-40 … +80 °C

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

Protection class IP

IP20

IP20

Design, dimensions and weight

Design

Modular

Modular

Width

242 mm

344 mm

Height

145 mm

145 mm

Depth

117 mm

117 mm

Net weight

1.9 kg

3.07 kg

Type of mounting

  • 35 mm DIN rail mounting

Yes

Yes

  • wall mounting

No

No

  • S7-300 rail mounting

Yes

Yes

Type of mounting

-

-

Product properties, functions, componentsgeneral

Cascading in the case of a redundant ring at reconfiguration time of <'~0.3'~s

50

50

Cascading in cases of star structuring

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functionsmanagement, configuration

Product function

  • CLI

Yes

Yes

  • web-based management

Yes

Yes

  • MIB support

Yes

Yes

  • TRAPs via email

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

  • RMON

Yes

Yes

  • SMTP server

Yes

Yes

  • Port mirroring

Yes

Yes

  • CoS

Yes

Yes

  • for IRT PROFINET IO switch

-

-

  • PROFINET IO diagnosis

Yes

Yes

  • switch-managed

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

  • HTTP

Yes

Yes

  • HTTPS

Yes

Yes

  • TFTP

Yes

Yes

  • FTP

Yes

Yes

  • BOOTP

Yes

Yes

  • SNMP v1

Yes

Yes

  • SNMP v2

Yes

Yes

  • SNMP v3

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

  • GMRP

Yes

Yes

  • DCP

Yes

Yes

  • LLDP

Yes

Yes

Identification & maintenance

  • I&M0 - device-specific information

Yes

Yes

  • I&M1 - plant identification/location name

Yes

Yes

Product functionsDiagnosis

Product function

  • Port diagnostics

Yes

Yes

  • Statistics Packet Size

Yes

Yes

  • Statistics packet type

Yes

Yes

  • Error statistics

Yes

Yes

  • SysLog

Yes

Yes

Product functionsVLAN

Product function

  • VLAN - port based

Yes

Yes

  • VLAN dynamic

Yes

Yes

Number of VLANs maximum

64

64

Number of VLANs - dynamic maximum

64

64

Protocol is supported GVRP

Yes

Yes

Product functionsDHCP

Product function

  • DHCP client

Yes

Yes

  • DHCP Option 82

Yes

Yes

  • DHCP Option 66

Yes

Yes

  • DHCP Option 67

Yes

Yes

Product functionsRouting

Product function

  • static IP routing

No

Yes

  • dynamic IP routing

No

Yes

Protocol is supported

  • RIPv2

No

Yes

  • OSPFv2

No

Yes

  • VRRP

No

Yes

Product functionsRedundancy

Product function

  • Ring redundancy

Yes

Yes

  • Redundancy manager

Yes

Yes

  • Standby redundancy

Yes

Yes

  • HSR redundancy protocol

Yes

Yes

  • MRP redundancy protocol

Yes

Yes

  • redundancy procedure STP

Yes

Yes

  • RSTP redundancy protocol

Yes

Yes

  • Passive listening

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

  • STP

Yes

Yes

  • RSTP

Yes

Yes

  • RSTP big network support

Yes

Yes

  • LACP

Yes

Yes

Product functionsSecurity

Product function

  • ACL - MAC-based

Yes

Yes

  • ACL - port/MAC-based

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

  • broadcast blocking

Yes

Yes

Protocol is supported SSH

Yes

Yes

Product functionsTime

Product function SICLOCK support

Yes

Yes

Protocol is supported

  • NTP

No

No

  • SNTP

Yes

Yes

Standards, specifications, approvals

Standard

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4 A, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4 A, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

  • for interference immunity

EN 61000-6-2:2001

EN 61000-6-2:2001

Verification of suitability

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

  • CE mark

Yes

Yes

  • C-Tick

Yes

Yes

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

  • Germanische Lloyd (GL)

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes


Order No.

6GK5 492-2AL00-8AA2

6GK5 492-2AM00-8AA2

6GK5 492-2AN00-8AA2

6GK5 492-2AP00-8AA2

6GK5 492-2AQ00-8AA2

Product type designation

MM492-2

MM492-2LD

MM492-2LH

MM492-2LH+

MM492-2ELH

Transmission rate

Transfer rate 1

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

1 000 Mbit/s

Transfer rate 2

-

-

-

-

-

Transfer rate 3

-

-

-

-

-

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

2

2

2

2

2

Number of electrical connections

  • for network components and terminal equipment

-

-

-

-

-

  • for Power-over-Ethernet for network components or terminal equipment

-

-

-

-

-

Design of electrical connection

  • for network components and terminal equipment

-

-

-

-

-

  • for Power-over-Ethernet for network components or terminal equipment

-

-

-

-

-

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

-

-

-

-

-

  • at 1000 Mbit/s

2

2

2

2

2

Design of optical interface for optical waveguide

  • at 100 Mbit/s

-

-

-

-

-

  • at 1000 Mbit/s

SC port (multimode up to 0.75 km)

SC port (singlemode up to 10 km)

SC port (singlemode up to 40 km)

SC port (singlemode up to 70 km)

SC port (singlemode up to 120 km)

design of the optical connection for fibre optic cable at 10 Gbit/s

-

-

-

-

-

Connectable optical power relative to 1 mW

  • of the transmitter output

-9.5 … -4 dB

-9.5 … -3 dB

-6 … +0 dB

0 … 5 dB

0 … 5 dB

  • of the receiver input maximum

-3 dB

-3 dB

-3 dB

-3 dB

-3 dB

Optical sensitivity relative to 1 mW of the receiver input minimum

-17 dB

-21 dB

-23 dB

-23 dB

-30 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

3 dB

8 dB

8 dB

Range at the optical interface depending on the optical fiber used

0 … 0.75 km

0 … 10 km

8 … 40 km

30 … 70 km

37 … 120 km

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

  • during transport

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

95 %

Protection class IP

IP20

IP20

IP20

IP20

IP20

Design, dimensions and weight

Design

Media module

Media module

Media module

Media module

Media module

Width

35 mm

35 mm

35 mm

35 mm

35 mm

Height

145 mm

145 mm

145 mm

145 mm

145 mm

Depth

90 mm

90 mm

90 mm

90 mm

90 mm

Net weight

0.25 kg

0.25 kg

0.25 kg

0.25 kg

0.25 kg

Type of mounting Installation in media module slot

Yes

Yes

Yes

Yes

Yes

Type of mounting

-

-

-

-

-

Standards, specifications, approvals

Standard

  • for EMC

-

-

-

-

-

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

  • for interference immunity

EN 61000-6-2:2001

EN 61000-6-2:2001

EN 61000-6-2:2001

EN 61000-6-2:2001

EN 61000-6-2:2001

Verification of suitability

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

  • CE mark

Yes

Yes

Yes

Yes

-

  • C-Tick

Yes

Yes

Yes

Yes

-

  • IEC 61850-3

-

-

-

-

-

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

Yes

Yes

Yes

  • Germanische Lloyd (GL)

Yes

Yes

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

Yes

Yes


Order No.

6GK5 491-2AB00-8AA2

6GK5 491-2AC00-8AA2

6GK5 491-2AE00-8AA2

Product type designation

MM491-2

MM491-2LD

MM491-2LH+

Transmission rate

Transfer rate 1

100 Mbit/s

100 Mbit/s

100 Mbit/s

Transfer rate 2

-

-

-

Transfer rate 3

-

-

-

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

2

2

2

Number of electrical connections

  • for network components and terminal equipment

-

-

-

  • for Power-over-Ethernet for network components or terminal equipment

-

-

-

Design of electrical connection

  • for network components and terminal equipment

-

-

-

  • for Power-over-Ethernet for network components or terminal equipment

-

-

-

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

2

2

2

  • at 1000 Mbit/s

-

-

-

Design of optical interface for optical waveguide

  • at 100 Mbit/s

BFOC sockets (multimode up to 5 km)

BFOC port (singlemode up to 26 km)

SC port (singlemode up to 70 km)

Connectable optical power relative to 1 mW

  • of the transmitter output

-19 … -14 dB

-15 … -8 dB

-5 … +0 dB

  • of the receiver input maximum

-3 dB

-3 dB

-3 dB

  • at 1000 Mbit/s

-

-

-

design of the optical connection for fibre optic cable at 10 Gbit/s

-

-

-

Optical sensitivity relative to 1 mW of the receiver input minimum

-32 dB

-34 dB

-34 dB

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

3 dB

Range at the optical interface depending on the optical fiber used

0 … 5 km

0 … 26 km

12 … 70 km

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

  • during transport

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

Protection class IP

IP20

IP20

IP20

Design, dimensions and weight

Design

Media module

Media module

Media module

Width

35 mm

35 mm

35 mm

Height

145 mm

145 mm

145 mm

Depth

90 mm

90 mm

90 mm

Net weight

0.26 kg

0.26 kg

0.26 kg

Type of mounting Installation in media module slot

Yes

Yes

Yes

Type of mounting

-

-

-

Standards, specifications, approvals

Standard

  • for EMC

-

-

-

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

  • for interference immunity

EN 61000-6-2:2001

EN 61000-6-2:2001

EN 61000-6-2:2001

Verification of suitability

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

  • CE mark

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

  • IEC 61850-3

-

-

-

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

Yes

  • Germanische Lloyd (GL)

Yes

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes


Order No.

6GK5 495-8BA00-8AA2

6GK5 496-4MA00-8AA2

Product type designation

EM495-8

EM496-4

Transmission rate

Transfer rate 1

10 Mbit/s

100 Mbit/s

Transfer rate 2

100 Mbit/s

-

Transfer rate 3

-

-

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

8

8

Number of electrical connections

  • for network components and terminal equipment

8

-

  • for media module

-

4

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

-

Number of optical interfaces for optical waveguide

  • at 100 Mbit/s

-

-

  • at 1000 Mbit/s

-

-

Design of optical interface for optical waveguide

  • at 100 Mbit/s

-

Dependent on selected media modules

  • at 1000 Mbit/s

-

Dependent on selected media modules

Permitted ambient conditions

Ambient temperature

  • during operating

-40 … +70 °C

-40 … +70 °C

  • during storage

-40 … +80 °C

-40 … +80 °C

  • during transport

-40 … +80 °C

-40 … +80 °C

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

Protection class IP

IP20

IP20

Design, dimensions and weight

Design

Extender module

Extender module

Width

112.4 mm

112.4 mm

Height

86 mm

154 mm

Depth

145 mm

145 mm

Net weight

0.56 kg

0.98 kg

Type of mounting

  • 35 mm DIN rail mounting

-

-

  • wall mounting

-

-

  • S7-300 rail mounting

-

-

Type of mounting

-

-

Standards, specifications, approvals

Standard

  • for EMC

-

-

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Division 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1-03

UL 60950-1, CSA C22.2 No. 60950-1-03

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2001 (Class A)

EN 61000-6-4:2001 (Class A)

  • for interference immunity

EN 61000-6-2:2001

EN 61000-6-2:2001

Verification of suitability

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

  • CE mark

Yes

Yes

  • C-Tick

Yes

Yes

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

  • Germanische Lloyd (GL)

Yes

Yes

  • Lloyds Register of Shipping (LRS)

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes
























































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET ECOFAST Введение Industrial Ethernet Введение Передача данных Обзор коммуникаций Топологии Критерии выбора типа сети Сетевые компоненты для Industrial Ethernet Industrial Ethernet коммутаторы Overview Компактные коммутаторы CSM Неуправляемые коммутаторы SCALANCE X-000 Неуправляемые коммутаторы/конверторы SCALANCE X-100 Управляемые коммутаторы SCALANCE X-200 Управляемые коммутаторы SCALANCE X-200IRT Управляемые коммутаторы SCALANCE X-300 Управляемые коммутаторы (Уровень 3) SCALANCE X-400 Модульные коммутаторы SCALANCE X-400 SCALANCE X-500 managed (Layer 3) Модуль ELS для Industrial Ethernet Модули ESM для Industrial Ethernet Активные сетевые компоненты Безопасность передачи данных в промышленных сетях Системные интерфейсы Аксессуары Управление сетью Сетевые переходы Решения партнеров PROFINET PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366
Яндекс.Метрика