SIPLUS SCALANCE X-100 unmanaged

Order No.

6GK5 104-2BB00-2AA3

6GK5 106-1BB00-2AA3

6GK5 108-0BA00-2AA3

6GK5 108-0PA00-2AA3

Product type designation

SCALANCE X104-2

SCALANCE X106-1

SCALANCE X108

SCALANCE X108PoE

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

100 Mbit/s

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

6

7

8

8

Number of electrical connections

  • for network components and terminal equipment

4

6

8

6

  • for Power-over-Ethernet for network components or terminal equipment

-

-

-

2

  • for alarm contact

1

1

1

1

  • for power supply

1

1

1

1

  • for redundant power supply

1

1

1

1

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

  • for Power-over-Ethernet for network components or terminal equipment

-

-

-

RJ45 port

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

  • at 10 Mbit/s

-

-

-

-

  • at 100 Mbit/s

2

1

-

-

Design of optical interface for optical waveguide

  • at 10 Mbit/s

-

-

-

-

  • at 100 Mbit/s

BFOC sockets (multimode up to 5 km)

BFOC sockets (multimode up to 5 km)

-

-

Connectable optical power relative to 1 mW

  • of the transmitter output

-19 … -14 dB

-19 … -14 dB

- -

- -

  • of the receiver input maximum

-14 dB

-14 dB

-

-

Optical sensitivity relative to 1 mW of the receiver input minimum

-32 dB

-32 dB

-

-

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

0 dB

-

-

Range at the optical interface depending on the optical fiber used

0 … 5 km

0 … 5 km

- -

- -

Inputs/outputs

Operating current of signaling contacts at AC maximum

-

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

DC

DC

Supply voltage external

24 V

24 V

24 V

24 V

  • minimum

18 V

18 V

18 V

18 V

  • maximum

32 V

32 V

32 V

32 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Type of fusing at input for supply voltage

4 A / 125 V

Consumed current maximum

0.16 A

0.15 A

0.14 A

1.7 A

Active power loss at 24 V for DC

3.8 W

3.6 W

3.36 W

10 W

Permitted ambient conditions

Ambient temperature

  • during operating

-10 … +60 °C

-10 … +60 °C

-20 … +70 °C

-20 … +60 °C

  • during storage

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

  • during transport

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

95 %

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Compact

Compact

Width

60 mm

60 mm

60 mm

60 mm

Height

125 mm

125 mm

125 mm

125 mm

Depth

124 mm

124 mm

124 mm

124 mm

Net weight

0.78 kg

0.78 kg

0.78 kg

0.9 kg

Type of mounting

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

Type of mounting

-

-

-

-

Product properties, functions, componentsgeneral

Cascading in cases of star structuring

-

-

-

-

Standards, specifications, approvals

Standard

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T..

FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T..

FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T..

FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T..

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T..

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T..

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T..

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T..

  • for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4:2001

  • for interference immunity

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2:2001

Verification of suitability

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2, EN 61000-6-4

EN 61000-6-2:2001, EN 61000-6-4:2001

  • CE mark

Yes

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

-

-

-

-

  • Railway application in accordance with EN 50124-1

-

-

-

-

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

No

  • Bureau Veritas (BV)

Yes

Yes

Yes

No

  • Det Norske Veritas (DNV)

Yes

Yes

Yes

No

  • Germanische Lloyd (GL)

Yes

Yes

Yes

No

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

No

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

No

Marine classification association/ Polski Rejestr Statkow (PRS)

Yes

Yes

Yes

No


Order No.

6GK5 112-2BB00-2AA3

6GK5 116-0BA00-2AA3

6GK5 124-0BA00-2AA3

Product type designation

SCALANCE X112-2

SCALANCE X116

SCALANCE X124

Transmission rate

Transfer rate 1

10 Mbit/s

10 Mbit/s

10 Mbit/s

Transfer rate 2

100 Mbit/s

100 Mbit/s

100 Mbit/s

Interfaces

Number of electrical/optical connections for network components or terminal equipment maximum

14

16

24

Number of electrical connections

  • for network components and terminal equipment

12

16

24

  • for Power-over-Ethernet for network components or terminal equipment

-

-

-

  • for alarm contact

1

1

1

  • for power supply

1

1

1

  • for redundant power supply

1

1

1

Design of electrical connection

  • for network components and terminal equipment

RJ45 port

RJ45 port

RJ45 port

  • for Power-over-Ethernet for network components or terminal equipment

-

-

-

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

Number of optical interfaces for optical waveguide

  • at 10 Mbit/s

-

-

-

  • at 100 Mbit/s

2

-

-

Design of optical interface for optical waveguide

  • at 10 Mbit/s

-

-

-

  • at 100 Mbit/s

BFOC sockets (multimode up to 5 km)

-

-

Connectable optical power relative to 1 mW

  • of the transmitter output

-19 … -14 dB

- -

- -

  • of the receiver input maximum

-14 dB

-

-

Optical sensitivity relative to 1 mW of the receiver input minimum

-32 dB

-

-

Attenuation of fiber-optic cable transmission link minimum necessary

0 dB

-

-

Range at the optical interface depending on the optical fiber used

0 … 5 km

- -

- -

Inputs/outputs

Operating current of signaling contacts at AC maximum

-

-

-

Operating voltage of signaling contacts at DC rated value

24 V

24 V

24 V

Operating current of signaling contacts at DC maximum

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

Type of voltage of supply voltage

DC

DC

DC

Supply voltage external

24 V

24 V

24 V

  • minimum

18 V

18 V

18 V

  • maximum

32 V

32 V

32 V

Product component fusing at power supply input

No

No

No

Type of fusing at input for supply voltage

-

-

-

Consumed current maximum

0.45 A

0.3 A

0.45 A

Active power loss at 24 V for DC

5.16 W

4.4 W

4.8 W

Permitted ambient conditions

Ambient temperature

  • during operating

-10 … +70 °C

-20 … +70 °C

-20 … +70 °C

  • during storage

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

  • during transport

-40 … +80 °C

-40 … +80 °C

-40 … +80 °C

Relative humidity at 25 °C without condensation during operating maximum

95 %

95 %

95 %

Protection class IP

IP30

IP30

IP30

Design, dimensions and weight

Design

Compact

Compact

Compact

Width

120 mm

120 mm

180 mm

Height

125 mm

125 mm

125 mm

Depth

124 mm

124 mm

124 mm

Net weight

1.1 kg

1.1 kg

1.5 kg

Type of mounting

  • 35 mm DIN rail mounting

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Type of mounting

-

-

-

Product properties, functions, componentsgeneral

Cascading in cases of star structuring

-

-

-

Standards, specifications, approvals

Standard

  • for EMC from FM

FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T..

FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T..

FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T..

  • for hazardous zone

EN 60079-0:2006, EN60079-15:2005, II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X

EN 60079-0:2006, EN60079-15:2005, II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X

EN 60079-0:2006, EN60079-15:2005, II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X

  • for safety of CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous area of CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T..

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T..

UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T..

  • for emitted interference

EN 61000-6-4:2001

EN 61000-6-4:2001

EN 61000-6-4:2001

  • for interference immunity

EN 61000-6-2:2001

EN 61000-6-2:2001

EN 61000-6-2:2001

Verification of suitability

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

EN 61000-6-2:2001, EN 61000-6-4:2001

  • CE mark

Yes

Yes

Yes

  • C-Tick

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

-

-

-

  • Railway application in accordance with EN 50124-1

-

-

-

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

No

No

No

  • Germanische Lloyd (GL)

No

No

No

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

Marine classification association/ Polski Rejestr Statkow (PRS)

No

No

No
























































Каталог оборудования 2012
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET ECOFAST Введение Industrial Ethernet Введение Передача данных Обзор коммуникаций Топологии Критерии выбора типа сети Сетевые компоненты для Industrial Ethernet Industrial Ethernet коммутаторы Overview Компактные коммутаторы CSM Неуправляемые коммутаторы SCALANCE X-000 Неуправляемые коммутаторы/конверторы SCALANCE X-100 Неуправляемые коммутаторы SCALANCE X-100 Неуправляемые коммутаторы SIPLUS SCALANCE X-100 Неуправляемые конверторы серии SCALANCE X-100 Конверторы SIPLUS SCALANCE X-100 Управляемые коммутаторы SCALANCE X-200 Управляемые коммутаторы SCALANCE X-200IRT Управляемые коммутаторы SCALANCE X-300 Управляемые коммутаторы (Уровень 3) SCALANCE X-400 SCALANCE X-500 managed (Layer 3) Модуль ELS для Industrial Ethernet Модули ESM для Industrial Ethernet Активные сетевые компоненты Безопасность передачи данных в промышленных сетях Системные интерфейсы Аксессуары Управление сетью Сетевые переходы Решения партнеров PROFINET PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо