Mode of operation |
|
---|---|
Measuring principle |
Ultrasonic level measurement |
Measuring range |
0.3 to 15 m (1 to 50 ft) |
Measuring points |
1 or 2 |
Output |
|
Ultrasonic transducer |
44 kHz |
Relays |
5 relays, rated 5 A at 250 V AC, non-inductive
|
Accuracy |
|
Error in measurement |
0.25% of range or 6 mm (0.24"), whichever is greater |
Resolution |
0.1% of measuring range or 2 mm (0.08"), whichever is greater1) |
Temperature compensation |
-50 to +150 °C (-58 to +302 °F)
|
Rated operating conditions |
|
Ambient conditions |
|
Ambient temperature for enclosure |
-20 to +50°C (-4 to +122 °F) |
Design |
|
|
DIN 3 HU/21 pitch, 4-rail plug-in unit suitable for standard 3 HU/84 pitch (19") rack |
|
Suitable for standard panel cutout DIN 43700 72 x 144 mm, |
Weight (rack and panel mount) |
1.5 kg (3.3 lbs) |
Weight (wall mount) |
2.5 kg (5.5 lbs) |
Communications |
|
|
Siemens Dolphin protocol, Modbus RTU and ASCII |
|
SmartLinx compatible, RS-485 |
Power supply |
100 to 230 V AC ± 15%, 50/60 Hz, 36 VA (17 W) or 12 to 30 V DC, 20 W |
Ultrasonic transducer |
Compatible transducers: ST-H and Echomax® series |
mA output signal |
2-core copper conductor, twisted, shielded, 0.5 to 0.75 mm (22 to 18 AWG), Belden® 8760 or equivalent is acceptable |
Displays and controls |
|
|
75 x 20 mm (3 x 0.8") LCD (selectable backlighting) |
|
100 x 40 mm (4 x 1.5") multfield LCD, backlit |
Programming |
Using removable handheld programmer (ordered separately) or Dolphin Plus software (option) |
Memory |
1 Mbyte RAM (static) with battery, 1 Mbyte flash EPROM |
Certificates and approvals |
CE, FM, CSA |
1) The measuring range corresponds to the distance from the zero point to the sensor face, plus any range extension (P801)