LZS:PT5B5R24 | 0.09 | 41H | КОМПЛЕКТНОЕ ВТЫЧНОЕ РЕЛЕ UNIT AC 24V. 4 CO CONTACT СВЕТОДИОДНЫЙ МОДУЛЬ RED SOCKET W. LOGIC ISOLATION SCREW TERMINAL 3.5 MM PINNING | 18.63 |
Plug-in relay coupling links can be ordered complete or as single modules.
Function
The semiconductor couplers have a low power consumption and are therefore particularly well suited for solid-state systems. In the versions equipped with LEDs, these indicate the switching state. In accordance with
The relay couplers LSZ:PT and LZS:MT have a test button. This can be used to force the plug-in relay coupler without electrical control into the tripped state and to lock it. This is indicated by a raised petrol-colored lever.
Control with solid-state output
In the case of solid-state outputs (e. g. proximity switch) with overload and short-circuit protection, you must make allowance during configuration for the temporarily flowing capacitor charging currents! This is possible, for example, by using a suitable LZS plug-in relay coupler.
Surge suppression
The 24 V DC relays LZX:RT and LZX: PT with LEDs can be supplied with, all others without integral surge suppression (freewheel diode connected in parallel with A1/A2). The positive control supply voltage must be connected to coil terminal A1.
Mounting
The relays are plugged into the base and this is snapped onto a TH 35 standard mounting rail according to IEC 60715.
A retaining bracket can be ordered for the MT series that additionally fixes the relay into a plug-in base (under conditions of increased mechanical stress). For the RT and PT series, a combined fixing and ejection bracket is available which can be used to disassemble the relay where access is difficult, for example, when relays are mounted side-by-side.
They can be mounted as required.
Logical disconnection
The terminals for the contacts and the terminals for the coil are arranged on separate levels, e. g. above for contacts and below for coil. Logical isolation is not necessarily safe isolation.
Protective separation
For safe isolation, transfer of the voltage of one circuit to another circuit is prevented to a suitable degree of safety (requirements and tests are described in IEC 60947-1 in Appendix N).
Notes on the previous LZX series
The complete units and accessory parts in the LZX series are no longer listed in this catalog. Complete units in the LZS series are fully compatible with the corresponding units in the LZX series. At the same time prices for the LZS series are lower than for the previous LZX series.
The LZX series plug-in relays are still available, and are used accordingly in both the LZS and the LZX series.
Note:
Due to differences in geometry the LED modules, plug-in bases, retaining brackets and labels can be combined and/or used in only the respective series, LZS or LZX.
The LZS series offers not only service-proven screw connections but also versions with plug-in terminals.