Siemens
ÑÐÅÄÑÒÂÀ ÏÐÎÌÛØËÅÍÍÎÉ ÀÂÒÎÌÀÒÈÇÀÖÈÈ
îôèöèàëüíûé ïàðòíåð Ñèìåíñ
Êàòàëîã ÑÀ01 2017
àðõèâíûé
(4872) 700-366
skenergo@mail.ru

Supplementary system components
Intelligent Operator Panel IOP Handheld

IOP Handheld for mobile use

The Intelligent Operator Panel IOP Handheld is a very user-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G110D, SINAMICS G120D and SINAMICS G110M distributed inverters.

The IOP supports both entry-level personnel and drive experts. Thanks to the large plain text display, the menu-based operation and the application wizards, it is easy to commission standard drives. A drive can be essentially commissioned without having to use a printed parameter list – as the parameters are displayed in plain text, and explanatory help texts and a parameter filtering function are provided.

Application wizards interactively guide you when commissioning important applications such as conveyor technology, pumps, fans and compressors.

There is a basic commissioning wizard for general commissioning.

The drives are easily controlled manually using directly assigned buttons and the navigation wheel. The IOP Handheld has a dedicated switchover button to switch over from automatic to manual mode.

The inverter can be diagnosed in a user-friendly fashion using the plain text display of faults and alarms. Help texts can be obtained by pressing the INFO button.

Up to two process values can be graphically visualized and up to four process values can be numerically visualized on the status screen/display.

Process values can also be displayed in technological units.

The IOP Handheld supports standard commissioning of identical drives. For this purpose, a parameter list can be copied from an inverter into the IOP Handheld and when required, downloaded into other drive units of the same type.

The IOP supports the following languages 1): German, English, French, Italian, Spanish, Portuguese, Dutch, Swedish, Russian, Czech, Polish, Turkish, Finnish.

In addition to the IOP, the IOP Handheld includes a housing with the rechargeable batteries, charging unit and RS232 connecting cable. The charging unit is supplied with connector adapters for Europe, the US and UK. When the batteries are fully charged, the operating time is up to 8 hours.

To connect the IOP handheld to SINAMICS G110D, SINAMICS G120D and SINAMICS G110M, the RS232 connecting cable with optical interface is required in addition.

Updating the IOP Handheld

The IOP Handheld can be updated and expanded using the integrated USB interface.

Data to support future drive systems can be transferred from the PC to the IOP Handheld via drag & drop. Further, the USB interface allows user languages and wizards that will become available in the future to be subsequently downloaded and the firmware to be updated for the IOP Handheld 1).

1) For additional information, see
https://support.industry.siemens.com/cs/document/67273266

Selection and ordering data

Description

Article No.

IOP Handheld

For use with SINAMICS G120, SINAMICS G120C, SINAMICS G120P, SINAMICS G110D, SINAMICS G120D, SINAMICS G110M and SINAMICS S110

Included in the scope of delivery:

  • IOP
  • Handheld housing
  • Rechargeable batteries (4 ? AA)
  • Charging unit (international)
  • RS232 connecting cable (3 m/9.84 ft long, for use with SINAMICS G120, SINAMICS G120C, SINAMICS G120P and SINAMICS S110)
  • USB cable (1 m/3.28 ft long)

6SL3255-0AA00-4HA0

RS232 connecting cable

With optical interface to connect the SINAMICS G110D, SINAMICS G120D or SINAMICS G110M inverters to the IOP Handheld (2.5 m/8.2 ft long)

3RK1922-2BP00



Memory card

SINAMICS memory card (SD card)

The parameter settings for an inverter can be stored on the SINAMICS SD card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediately ready for use again.

  • Parameter settings can be written from the memory card to the inverter or saved from the inverter to the memory card.
  • Up to 100 parameter sets can be stored.
  • The memory card supports standard commissioning without the use of the Intelligent Operator Panel IOP Handheld or the STARTER and SINAMICS Startdrive commissioning tools.

Note:

The memory card is not required for operation and does not have to remain inserted.

Selection and ordering data

Description

 

Article No.

SINAMICS memory card (SD card)

512 MB

 

6SL3054-4AG00-2AA0

Optional firmware memory card

SINAMICS SD card 512 MB + firmware V4.7

(Multicard V4.7)

NEW

6SL3054-7EH00-2BA0

SINAMICS SD card 512 MB + Firmware V4.7 SP6 HF1

(Multicard V4.7 SP6 HF1)

NEW

6SL3054-7TD00-2BA0



For more information on firmware V4.7:

https://support.industry.siemens.com/cs/document/92554110

Additional information on firmware V4.7 SP6 HF1:

https://support.industry.siemens.com/cs/document/109482094

PC inverter connection kit 2 (mini USB interface cable for communication with a PC)

For controlling and commissioning an inverter directly from a PC via a point-to-point connection if the appropriate software (STARTER commissioning tool1), V4.3 SP3 and higher or SINAMICS Startdrive V13 and higher) has been installed.

Selection and ordering data

Description

Article No.

PC inverter connection kit 2

USB cable (3 m/9.84 ft long) for

  • SINAMICS G120C
  • SINAMICS G120 Control Units
    • CU230P-2
    • CU240B-2
    • CU240E-2
    • CU250S-2
  • SINAMICS G110M Control Units
    • CU240M
  • SINAMICS G120D Control Units
    • CU240D-2
    • CU250D-2

6SL3255-0AA00-2CA0



1) The STARTER commissioning tool is also available on the Internet at
https://support.industry.siemens.com/cs/ww/en/ps/13437/dl

Wall mounting kit

SINAMICS G110M wall mounting kit

A wall mounting kit is available if SINAMICS G110M should not be mounted on a (geared) motor. With the wall mounting kit the SINAMCS G110M frequency inverter can be mounted close to the motor in the application and can thus be used flexibly, adapted to the conditions of the application.

The wall mounting kit contains a metal cable gland for connecting the motor cable (max. 5 m/16.41 ft shielded) and a fan including connecting cable for cooling the Power Module.

Note:

Only one of the CU240M Control Units for motor frame size 71 can be fitted onto a wall mounting kit.
The degree of protection with a wall mounting kit is IP66/UL Type 12.

Compatible CU240M Control Units

Control Unit

Communications via

Connection system

Control Unit for motor frame size 71

CU240M

USS, Modbus RTU

Screw-type version

6SL3544-0LB02-1BA0

CU240M AS-i

AS-Interface

Screw-type version

6SL3544-0LB02-1MA0

Plug-in version

6SL3544-0TB02-1MA0

CU240M DP

PROFIBUS

Screw-type version

6SL3544-0LB02-1PA0

Plug-in version

6SL3544-0TB02-1PA0

CU240M PN

PROFINET, EtherNet/IP

Screw-type version

6SL3544-0LB02-1FA0

Plug-in version

6SL3544-0TB02-1FA0



Selection and ordering data

Description

 

Article No.

Wall mounting kit

NEW

6SL3566-1GA00-0GA0

Spare part

Replacement fan

for wall mounting kit
(includes fan, connecting cable and cable gland)

NEW

6SL3500-0TF02-0AA0



Dimensional drawings

SINAMICS G110M wall mounting kit

Installation kits

Different installation kits can be ordered as accessories for the Control Units with plug-in connections and Control Units with cable gland connections.

These kits include covers or cable glands for protecting or connecting the 400 V 3 AC supply, the 24 V DC supply and the mechanical motor brake.

Selection and ordering data

Description

Article No.

Installation kit for Control Units with cable gland connections

Includes cable glands for connecting the 400 V 3 AC supply, the 24 V DC supply and the mechanical motor brake

6SL3566-2VA00-0GA0

Installation kit for Control Units with plug-in connections

Includes covers for protecting the 400 V 3 AC and 24 V DC input connectors and a cable gland for connecting the mechanical motor holding brake

6SL3566-2LA00-0GA0



STARTER commissioning tool

The STARTER commissioning tool (V4.3 SP3 and higher) supports the commissioning and maintenance of SINAMICS G110M inverters. The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily.

Selection and ordering data

Description

Article No.

STARTER commissioning tool 1)

on DVD?ROM

6SL3072-0AA00-0AG0



1) The STARTER commissioning tool is also available on the Internet at https://support.industry.siemens.com/cs/ww/en/ps/13437/dl

SINAMICS Startdrive commissioning tool

The SINAMICS Startdrive commissioning tool (V13 and higher) supports the commissioning and maintenance of SINAMICS G110M inverters. SINAMICS Startdrive is part of the TIA Portal engineering platform. It supports the intuitive integration of SINAMICS drives in automation. The same operator control concept, the elimination of interfaces and a high degree of user-friendliness make it possible to quickly integrate SINAMICS into an automation process and start it up with the TIA Portal. The TIA Portal with SINAMICS Startdrive offers you a totally integrated engineering platform for the complete application from the project engineering phase through to commissioning and diagnostics.

Selection and ordering data

Description

Article No.

SINAMICS Startdrive commissioning tool 1)

on DVD?ROM

6SL3072-4DA02-0XG0



1) The SINAMICS Startdrive commissioning tool is also available on the Internet at https://support.industry.siemens.com/cs/document/68034568

 

An overview of all available accessories (e.g. connectors and cables) can be found under the following link:
http://www.siemens.com/distributeddrives-supplementaryproducts

Connecting cables for the Control Unit

PROFINET connecting cable

Flexible plug-in cables and plug-in connectors that can be assembled in the field for transmission of data (up to 100 Mbit/s) between Industrial Ethernet stations with IP65 degree of protection.

Selection and ordering data

Description

Article No.

IE connecting cable M12?180/M12?180, axial outlet

Pre-assembled IE FC TP trailing cable GP 2 x 2 PROFINET type C with two 4-pole M12 plugs (4-pole, D-coded), IP65/IP67 degree of protection, UL, plug/plug connector (IN/OUT)
Length:

 

  • 0.3 m (0.98 ft)

6XV1870-8AE30

  • 0.5 m (1.64 ft)

6XV1870-8AE50

  • 1 m (3.28  ft)

6XV1870-8AH10

  • 1.5 m (4.92 ft)

6XV1870-8AH15

  • 2 m (6.56 ft)

6XV1870-8AH20

  • 3 m (9.84 ft)

6XV1870-8AH30

  • 5 m (16.41 ft)

6XV1870-8AH50

  • 10 m (32.81 ft)

6XV1870-8AN10

  • 15 m (49 ft)

6XV1870-8AN15

IE connecting cable M12-180/IE FC RJ45 Plug 145 axial outlet

Pre-assembled IE FC TP Trailing Cable GP 2 x 2 (PROFINET Type C) with M12 plugs (D-coded) and IE FC RJ45 plug, IP65/IP67 degree of protection

Length:

 
  • 2 m (6.56 ft)

6XV1871-5TH20

  • 3 m (9.84 ft)

6XV1871-5TH30

  • 5 m (16.41 ft)

6XV1871-5TH50

  • 10 m (32.81 ft)

6XV1871-5TN10

  • 15 m (49 ft)

6XV1871-5TN15

IE M12 Plug PRO axial outlet

For assembly in the field, M12 plug-in connector (D-coded), metal enclosure, UL, fast connection method, plug connector

 

  • 1 unit

6GK1901-0DB20-6AA0

  • 8 units

6GK1901-0DB20-6AA8



PROFIBUS connecting cable

Flexible plug-in cables/connectors for transmission of data (up to 12 Mbit/s) from PROFIBUS stations.

Selection and ordering data

Description

Article No.

PROFIBUS M12 plug-in cable axial outlet

Pre-assembled with two 5-pole M12 plug/socket connectors, UL
Length:

 

  • 0.3 m (0.98 ft)

6XV1830-3DE30

  • 0.5 m (1.64 ft)

6XV1830-3DE50

  • 1 m (3.28  ft)

6XV1830-3DH10

  • 1.5 m (4.92 ft)

6XV1830-3DH15

  • 2 m (6.56 ft)

6XV1830-3DH20

  • 3 m (9.84 ft)

6XV1830-3DH30

  • 5 m (16.41 ft)

6XV1830-3DH50

  • 10 m (32.81 ft)

6XV1830-3DN10

  • 15 m (49 ft)

6XV1830-3DN15

PROFIBUS M12 plug connector axial outlet

5-pole, B-coded, metal enclosure, 1 package = 5 units

 

  • Pin insert

6GK1905-0EA00

  • Female contact insert

6GK1905-0EB00



AS-Interface connecting cables

Selection and ordering data

Description

Article No.

AS-Interface M12 branch

To connect the AS-Interface and the UAux cable to an M12 socket, UL

 

  • 1 m (3.28 ft)

3RK1901-1NR21

  • 2 m (6.56 ft)

3RK1901-1NR22



Connecting cables/connectors for supplying the Control Unit with power

Selection and ordering data

Description

Article No.

7/8" plug-in cable, axial outlet

For 24 V switched and unswitched,
pre-assembled with 2 ? 7/8" at both ends (axial),
5 ? 1.5 mm2, 5-pole plug/socket connectors
Length:

 

  • 0.3 m (0.98 ft)

6XV1822-5BE30

  • 0.5 m (1.64 ft)

6XV1822-5BE50

  • 1 m (3.28  ft)

6XV1822-5BH10

  • 1.5 m (4.92 ft)

6XV1822-5BH15

  • 2 m (6.56 ft)

6XV1822-5BH20

  • 3 m (9.84 ft)

6XV1822-5BH30

  • 5 m (16.41 ft)

6XV1822-5BH50

  • 10 m (32.81 ft)

6XV1822-5BN10

  • 15 m (49 ft)

6XV1822-5BN15

7/8" power cable, angled outlet, pre-assembled at one end

For 24 V switched and unswitched,
pre-assembled with 1 ? 7/8" angled at one end,
5 ? 1.5 mm2 5-pole socket connector
Length:

 

  • 3 m (9.84 ft)

3RK1902-3GB30

  • 5 m (16.41 ft)

3RK1902-3GB50

  • 10 m (32.81 ft)

3RK1902-3GC10

7/8" power cable, angled outlet

For 24 V switched and unswitched,
pre-assembled with 2 ? 7/8" angled at both ends,
5 ? 1.5 mm2, 5-pole plug/socket connectors
Length:

 

  • 3 m (9.84 ft)

3RK1902-3NB30

  • 5 m (16.41 ft)

3RK1902-3NB50

  • 10 m (32.81 ft)

3RK1902-3NC10

7/8" plug-in connector, axial outlet

5-pole, B-coded, plastic enclosure, 1 package = 5 units

 

  • Pin insert (OUT)

6GK1905-0FA00

  • Female contact insert (IN)

6GK1905-0FB00

7/8" plug-in connector, angled outlet

5-pole, B-coded, plastic enclosure, 1 package = 5 units

 

  • Pin insert (OUT)

3RK1902-3BA00

  • Female contact insert (IN)

3RK1902-3DA00



Connecting cables and connectors for digital inputs and outputs

Selection and ordering data

Description

Article No.

M12 plug-in cable pre-assembled at both ends, axial outlet

M12 straight plug, M12 straight socket, screw mounting, 3-pole,
3 x 0.34 mm?, A-coded, black PUR sheath, max. 4 A
Length:

 

  • 1.5 m (4.92 ft)

3RK1902-4PB15-3AA0

M12 connector

Y cable for distributed I/Os for dual connection of I/Os using single 5?pole M12 cables, 200 mm (7.87 in)

 
  • Straight

6ES7194-6KA00-0XA0



Connecting cables and connectors for analog inputs

Selection and ordering data

Description

Article No.

M12 cable connector

8-pole plug connector

 
  • Straight cable outlet

Ordered from and supplied by KnorrTec

T distribution piece

To connect two analog inputs

8?pole M12 male connector to 2 ? 4-pole M12 socket, angled

Ordered from and supplied by KnorrTec



Connecting cables for Power Modules

Connecting cables pre-assembled at one end and connector sets to connect to the line supply

Selection and ordering data

Description

Article No.

Connecting cable pre-assembled at one end

Power supply cable, open at one end, for HAN Q4/2, angled, 4 ? 4 mm2

 

  • 1.5 m (4.92 ft) long

3RK1911-0DB13

  • 5 m (16.41 ft) long

3RK1911-0DB33

Connector set for the power supply

Female contact insert HAN Q4/2, 5 socket contacts, grommet housing, angled outlet including screw connection

 

  • 2.5 mm2

3RK1911-2BE50

  • 4 mm2

3RK1911-2BE10

  • 6 mm2

3RK1911-2BE30



Connector insert for power loop-through

Selection and ordering data

Description

Article No.

Connector set for power loop-through

Plug insert HAN Q4/2,
4 socket contacts, grommet housing, angled outlet including screw connection

 
  • 2.5 mm2

3RK1911-2BF50

  • 4 mm2

3RK1911-2BF10



Power bus distribution 400 V in IP65 degree of protection

Selection and ordering data

Not essential (daisy chaining within device); use is optional.

Description

Article No. (Ordering see Solution Partner)

Power T clamp connector for 2.5 ... 6 mm2

With attached 7-pole connector, female contact insert, grommet housing, UL

Seals for various cable cross-sections must be ordered separately

Ordered from and supplied by Harting

T clamp connector

Completely pre-assembled

Ordered from and supplied by KnorrTec

T distributor box, IDC connection power cable

Pre-assembled, UL, uncut power cable, 2.5 ... 6 mm2

Push-in connection: 1.5 ... 6 mm2

Seals for various cable cross-sections must be ordered separately

Ordered from and supplied by Weidmuller

Y distributor

For direct connection of 400 V supply line, HAN Q4/2, conductor cross-section 1.5 ... 4 mm2

Ordered from and supplied by Harting



















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
Êàòàëîã îáîðóäîâàíèÿ 2017
Siemens Industry Catalog Drive Technology Automation Technology Automation Systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial Communication Industrial Controls Industrial Communication AS-Interface Introduction ASIsafe Masters Routers Slaves I/O modules for use in the field, high degree of protection SIPLUS I/O modules for operation in the field, high degree of protect. I/O modules for use in the control cabinet Special integrated solutions Modules with special functions Contactors and contactor assemblies Load feeders for use in the control cabinet Motor starters for use in the field, high degree of protection General Motion Control SINAMICS G110M distributed inverters SINAMICS G110M distributed frequency inverters CU240M Control Units PM240M Power Modules Line-side components DC link components Compatible SIMOGEAR geared motors Supplementary system components Spare parts SINAMICS G110D distributed inverters Services and documentation SIRIUS ACT pushbuttons and indicator lights SIRIUS 3SF5 pushbuttons and indicator lights SIRIUS 8WD4 signaling columns AS-Interface connection for LOGO! Power supply units and data decoupling modules Transmission media System components and accessories Diagnostics Software IO-Link Switching Devices Protection Equipment Load Feeders and Motor Starters Monitoring and Control Devices Safety Technology Position and Safety Switches Commanding and Signaling Devices Parameterization, Configuration and Visualization with SIRIUS SITOP power supplies SIRIUS non-stabilized power supplies Transformers Filters Reactors Manufacturing Execution Systems (MES) SIMATIC IT PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supplies Products for specific requirements Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services ... and everything else you need




  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà