8 LEDs to display device operating states and errors – and for basic communication diagnostics.
Communication
2 x M12 [Ethernet 0 / Ethernet 1], 4-pole, D-coded, PROFINET IO with IRT. Integrated 2-port switch to configure a PROFINET line-type topology, e.g. with additional sensors and the SIMOTION control. In addition to real-time data, acyclic data such as sensor parameterization, and TCP/IP data, such as the signal trace, are also transferred via this interface. Matching M12 PROFINET prefabricated cables are available, or users can assemble them themselves (see PROFINET).
I/O devices
2 x fiber-optic cable connection, 3-pole, optical.
Plug-in screw connection for the fiber-optic cable, which is available in 2 lengths.
Power supply
1 x M12 plug connector for the 24 V DC electronics power supply
1 x M12 socket connector to loop through the electronics power supply
Option module
SIMOTION TRC3000 is available in two versions:
With one fiber-optic cable connection for single-sided measurement of wedge-shaped/block-shaped register marks on material webs
With two fiber-optic cable connections, for single-sided, two-sided and two-web measurement of wedge-shaped/block-shaped register marks and for horizontal mark arrangement on material webs. Note: The TRC3000 version with 2 fiber-optic cable connections can only be operated in mode 3 (where a maximum of 3 marks is measured). When using this version and carrying out a measurement with both fiber-optic cables, 1 gate is set, and both marks are expected within this gate.