Up to 1000 m above sea level without power derating
Maximum noise level
72 dB
Thermal class
F
Vibration severity grade
1PH11..-1.F
Grade B is maintained up to 1800 rpm Grade S is maintained from 1800 rpm to 10000 rpm
1PH11..-1.D
Grade B is maintained up to 1800 rpm Grade R is maintained from 1800 rpm to 6000 rpm
Shock resistance
2.25 m/s2 (continuous in axial direction); 10 m/s2 (continuous in radial direction)
Static bearing lifetime
> 20000 h1)
Oil seal lifetime
> 20000 h
Encoder lifetime
> 20000 h
Motor lifetime
20000 h
Degree of protection
IP54 (dust-tight and splash-proof during motor operation)
Type of construction
IM B5, IM B3, IM V1, and IM V5
Paint finish
Anthracite
Certificate of suitability
CE, EAC
1) This lifetime is only for reference. When a motor keeps running at rated speed under rated load, replace its bearing after 20000 hours to 30000 hours of service time. Even if the time is not reached, the bearing must be replaced when unusual noise, vibration, or faults are found.