Possible applications | Platform scales, hopper scales, vehicle scales |
Model | Double shear beam |
Rated load/maximum load Emax. | - 13.6 t (13.39 tn. l.)
- 18.1 t (17.81 tn. l.)
- 22.6 t (22.24 tn. l.)
- 27.2 t (26.77 tn. l.)
- 34 t (33.46 tn. l.)
|
Accuracy class according to OIML R60 | C3 |
Max. load cell verification intervals nLC | 3 000 |
Min. scale interval Vmin | Emax/10 000 |
Combined error Fcomb | ? ± 0.023 % Cn |
Min. dead load Emin | 0 kg |
Safe load limit Lu | 150 % Emax |
Ultimate load Ld | 300 % Emax |
Recommended supply voltage | 5 … 12 V DC |
Maximum supply voltage | 18 V DC |
Rated characteristic value Cn | 3.0 ± 0.008 mV/V |
Tolerance Do of zero signal | ? ± 1.0 % Cn |
Creep error 30 min Fcr | ? ± 0.015 % Cn |
Input resistance Re | 700 ± 7 ? |
Output resistance Ra | 703 ? ± 4 ? |
Insulation resistance Ris | ? 5 000 M? at 50 V DC |
Rated temperature range Btn | -10 … +40 °C (14 ... 104 °F) |
Operating temperature range Btu | -35 … +60 °C (-31 ... 140 °F) |
Storage temperature range Bts | -40 … +80 °C (-40 ... 176 °F) |
Sensor material (DIN) | Steel, nickel-plated |
Degree of protection according to EN 60529; IEC 60529 | IP67 |
Cable connection | |
Length of the connecting cable (four-core) | 9 m (30 ft) |
Diameter of the connecting cable | 8 mm |
Color coding of the connecting cable | Color |
| Red |
| Black |
| Green |
| White |
- Shield (not connected to the load cell body)
| Transparent |
ATEX | - |