General information | |
Product type designation | SM 1221 DI 8x24 VDC |
Supply voltage | |
Rated value (DC) | |
| Yes |
Input current | |
from backplane bus 5 V DC, max. | 105 mA |
Digital inputs | |
| 4 mA; per channel |
Output voltage | |
Power supply to the transmitters | |
| Yes |
Power loss | |
Power loss, typ. | 1.5 W |
Digital inputs | |
Number of digital inputs | 8 |
| 2 |
Input characteristic curve in accordance with IEC 61131, type 1 | Yes |
Number of simultaneously controllable inputs | |
all mounting positions | |
| 8 |
horizontal installation | |
| 8 |
| 8 |
vertical installation | |
| 8 |
Input voltage | |
| DC |
| 24 V |
| 5 V DC at 1 mA |
| 15 V DC at 2.5 mA |
Input current | |
| 1 mA |
| 2.5 mA |
| 4 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
| Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
for interrupt inputs | |
| Yes |
Cable length | |
| 500 m |
| 300 m |
Interrupts/diagnostics/status information | |
Alarms | Yes |
Diagnostic functions | Yes |
Alarms | |
| Yes |
Diagnostic messages | |
| Yes |
Diagnostics indication LED | |
| Yes |
| Yes |
Potential separation | |
Potential separation digital inputs | |
| 2 |
Isolation | |
Isolation tested with | According to EN 50155 (routine test) |
Degree and class of protection | |
Degree of protection acc. to EN 60529 | |
| Yes |
Standards, approvals, certificates | |
Railway application | |
| Yes; EMC for rail vehicles |
| Yes; EMC for signal and telecommunications systems |
| Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC |
| Yes; Rail vehicles - see ambient conditions |
| Yes; Stationary electrical equipment - see ambient conditions |
| Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) |
| Yes; Rail vehicles - temperature class T1, horizontal mounting position, salt spray Class ST2 |
| Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
| Yes; Rail vehicles - verification on request |
Ambient conditions | |
Free fall | |
| 0.3 m; five times, in product package |
Ambient temperature during operation | |
| -25 °C; = Tmin; Startup @ -25 °C |
| 60 °C; = Tmax; +70 °C for 10 minutes (T1 acc. to EN 50155) for horizontal mounting position |
Extended ambient conditions | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) |
Relative humidity | |
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 5B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation! |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 5C3 (RH < 75%) including salt spray according to EN 50155 (ST2). The supplied plug covers must remain in place over the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 5S3 including sand and dust. The supplied plug covers must remain in place over the unused interfaces during operation! |
Connection method | |
required front connector | Yes |
Mechanics/material | |
Enclosure material (front) | |
| Yes |
Dimensions | |
Width | 45 mm |
Height | 100 mm |
Depth | 75 mm |
Weights | |
Weight, approx. | 170 g |
Other | |
Note: | For use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A Online Support article 109736776 |