General features | |
Design | Panel PC built-in unit, protective enclosure available as an option |
Front | 15" and 19", optional 15" sunlight-readable displays |
Operation | Touch with 8 function keys |
Processor | Intel Atom E3845 with 1.91 GHz |
Main memory | 4 GB DDR2 SDRAM |
Operating system, preinstalled and configured | Windows 7 MUI, Windows 7 Ultimate, WES7 E |
Mass storage | 32 GB SSD, 128 GB SSD |
Power supply | 24 V DC, max. 2.1 A (19") |
Interfaces | |
Ethernet | 10/100 Mbit Ex e, or fiber-optics 100 Mbit (SC) Ex op is |
USB 2.0 | 2 x Ex i, 2 x Ex e (Zone 1) or 2 x Ex nA (Zone 2) |
Serial | 1 x RS232 or 1 x RS422/485 |
Ambient conditions | |
Degree of protection | IP66 at front, IP65 at rear, IP66 in protective enclosure |
Ambient temperature during operation | - 20 °C ... + 50 °C (cold start -10 °C) with optional auxiliary heater down to - 30 °C |
Relative humidity during operation | 90 % at + 40 °C, no condensation |
Approvals/directives | |
Devices in version "Zone 1" | |
ATEX directive 94/9/EC | |
| II 2 (2) G Ex d e ia ib mb [ia ib] IIC T4 Gb II 2 (2) D Ex ia tb [ia ib] IIIC T80°C Db IP66 |
| II 2 (2) G Ex d e ia ib mb [ia ib op is] IIC T4 Gb II 2 (2) D Ex ia tb [ia ib op is] IIIC T80°C Db IP66 |
IECEx | |
| Ex d e ia ib mb [ia ib] IIC T4 Gb Ex ia tb [ia ib] IIIC T80°C Db IP66 |
| Ex d e ia ib mb [ia ib op is] IIC T4 Gb Ex ia tb [ia ib op is] IIIC T80°C Db IP66 |
GOST-R | |
| 2 Ex d e ia ib mb [iaib] IIC T4 DIP A21 TA80°C, IP66 |
| 2 Ex d e ia ib mb [iaibopis] IIC T4 DIP A21 TA80°C, IP66 |
CSA | Ex d e ia ib mb [ia ib] IIC T4 Gb, Type 4X, IP66 Class II, Division 1, Groups E, F, G, T80°C Ex ia tb [ia ib] IIIC T80°C Db, IP66 |
KGS | Ex d e ia ib mb [ia ib] IIC T4 Ex ia tb [ia ib] IIIC T80°C Db IP66 |
InMetro | |
| Ex d e ia ib mb [ia ib] IIC T4 Gb Ex ia tb [ia ib] IIIC T80°C Db IP66 |
| Ex d e ia ib mb [ia ib op is] IIC T4 Gb Ex ia tb [ia ib op is] IIIC T80°C Db IP66 |
Device version "UL Class 1, Division 2" | Class 1, Division 2, Groups A, B, C, D Class 2, Division 2, Groups F, G Class 3, Hazardous Locations |
Devices in version "Zone 2" | |
ATEX directive 94/9/EC | |
| II 3 (2/3) G Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc II3 (2/3) D Ex ia tc [ib Db] [ic] IIIC T80°C Dc IP66 |
| II 3 (2/3) G Ex d e ia ib mb nA [ib op is Gb] [ic] IIC T4 Gc II 3 (2/3) D Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66 |
IECEx | |
| Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc Ex ia tc [ib Db] [ic] IIIC T80°C Dc IP66 |
| Ex d e ia ib mb nA [ib op is Gb] [ic] IIC T4 Gc Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66 |
GOST-R | |
| 2 Ex d e ia ib mb nA [ib][ic] IIC T4 DIP A21 TA80°C, IP66 |
| 2 Ex d e ia ib mb nA [ib opis][ic] IIC T4 DIP A21 TA80°C, IP66 |
CSA | Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc, Type 4X, IP66 Class II, Division 2, Groups E, F, G, T80°C; Ex ia tc [ib ic] IIIC T80°C Dc, IP66 |
InMetro | |
| Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc Ex ia tc [ib Db] [ic] IIIC T80°C Dc IP66 |
| Ex d e ia ib mb nA [ib op is Gb] IIC T4 Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66 |
Device version "UL Class 1, Division 2" | Class 1, Division 2, Groups A, B, C, D Class 2, Division 2, Groups F, G Class 3, Hazardous Locations |
Dimensions | |
Mounting dimensions (W x H x D) | 15": 427.5 mm x 327.5 mm x 165 mm 19": 522.5 mm x 412.5 mm x 165 mm |
Front dimensions (W x H) | 15": 440 mm x 340 mm 19": 535 mm x 425 mm |
Weight | 15": 15 kg 19": 23 kg |