Harbor cranesApplication range |
|---|
 | Container cranes | - STS (ship?to?shore) cranes
| Grab cranes | - GSU (grab ship unloader) cranes
| Stacking cranes | - ASC (automated stacking cranes)
| - RTG (rubber tired gantry) cranes
| - RMG (rail mounted gantry) cranes
|
Example: STS crane, lifting capacity up to 120 t, trolley speed up to 250 m/min Crane topology |
|---|
 | Drive system: SINAMICS S120 | Controller: SIMOTION D | SIMATIC S7 I/O: PROFIBUS/PROFINET | HMI/diagnostics: SIMOCRANE CMS with SIMATIC WinCC |
Drive systems |
|---|
| SINAMICS S120 high?performance multi?axis drive system |
|---|
 | Built?in units | - Infeed/regenerative feedback modules from 16 to 900 kW (up to 3420 kW through parallel connection)
| - Motor Modules for the operation of three?phase induction motors from 1.6 to 800 kW
| Cabinet units | - Line Connection Modules for connecting line?side components to the supply system
| - Active Line Modules for the infeed/regenerative feedback of 300 to 900 kW (up to 3420 kW through parallel connection)
| - Motor Modules for the operation of three?phase induction motors from 110 to 800 kW
| - Switch?Over Modules for connecting Motor Modules to motors for optimal utilization and/or redundancy of the drive components
| - Motor Multi Connection Modules for connecting several motors to a common Motor Module in multiple?motor applications for gantries
| - Motor Double Choke Modules for interconnecting motor reactors in applications with long motor cables, e.g. gantries
|
SIMOTICS motors |
|---|
| Three?phase induction motors for use with SINAMICS S120 |
|---|
 | Hoist motors | - SIMOTICS M?1PH8,
IP23/IP55, S1, 2.8 to 1340 kW, 13 to 12451 Nm
| - SIMOTICS SD 1LE1,
IP55, S1, 1.75 to 200 kW, 15 to 1546 Nm
| - SIMOTICS SD 1LG4/1LG6,
IP55, S1, 1.75 to 332 kW, 15 to 2323 Nm
| Gantry motors | - SIMOTICS SD 1LP4/1LP6, with a spring?operated brake,
IP55, S3?25 %, 3 to 132 kW, 30 to 873 Nm
|
|
|