General information | |
Product type designation | SIPLUS HMI KP8 PN |
Control elements | |
With parameterizable keys | Yes |
Keyboard fonts | |
| |
| Yes |
| |
| 8 |
| |
| 8 |
Expansions for operator control of the process | |
| 8; Adjustable brightness |
| 5; Red, green, blue, yellow, white |
| 8 |
Installation type/mounting | |
Mounting type | Clamp terminals |
Mounting position | vertical |
Rack mounting | No |
Front mounting | Yes; Compatible with extension unit dimensions |
Rail mounting | No |
Wall mounting/direct mounting | No |
Mounting in portrait format possible | Yes |
Mounting in landscape format possible | Yes |
maximum permissible angle of inclination without external ventilation | 30°; To the front/rear |
Number of slots for command devices and signaling units | 0 |
Supply voltage | |
Type of supply voltage | DC |
Rated value (DC) | 24 V; 24 V looped through at connector, no interruption on pulling |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Type of output | |
LED colors | |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Digital inputs | |
Number of digital inputs | 8; Max. 8 inputs and outputs (total) |
Input voltage | |
| 24 V |
Digital outputs | |
Number of digital outputs | 8; Max. 8 inputs and outputs (total) |
Short-circuit protection | Yes |
Switching capacity of the outputs | |
| 100 mA |
Output voltage | |
| 24 V; Non-isolated |
Total current of the outputs | |
| 100 mA |
| 800 mA |
Interfaces | |
Number of industrial Ethernet interfaces | 2; For the construction of lines and rings without external switch |
Number of PROFINET interfaces | 2; Incl. switch |
Industrial Ethernet | |
| 2; Per port |
| 2; Per port |
Protocols | |
PROFINET | Yes; also 3rd party PLC |
PROFINET CBA | No |
IRT | Yes |
MRP | Yes |
PROFIsafe | No |
PROFIBUS | No |
Test commissioning functions | |
Illuminant test | Yes; During switch on |
Key and signal lamp test | Yes; Automatically when switching on |
EMC | |
Emission of radio interference acc. to EN 55 011 | |
| Yes; Group 1, measured at a distance of 10 m |
| No |
Degree and class of protection | |
IP (at the front) | IP65 |
Enclosure Type 4 at the front | No |
Enclosure Type 4x at the front | Yes; Incl. NEMA12 |
IP (rear) | IP20 |
Standards, approvals, certificates | |
CE mark | Yes |
KC approval | Yes |
Suitable for safety functions | No |
Marine approval | |
| No |
| No |
| No |
| No |
| No |
| No |
| No |
Ambient conditions | |
Ambient temperature during operation | |
| -40 °C; = Tmin; Startup @ -25 °C |
| 60 °C; = Tmax |
| |
| -40 °C; = Tmin; Startup @ -25 °C |
| 60 °C; = Tmax |
| |
| -40 °C; = Tmin; Startup @ -25 °C |
| 45 °C; = Tmax |
| |
| -40 °C; = Tmin; Startup @ -25 °C |
| 60 °C; = Tmax |
| |
| -40 °C; = Tmin; Startup @ -25 °C |
| 45 °C; = Tmax |
Ambient temperature during storage/transportation | |
| -25 °C |
| 80 °C |
Extended ambient conditions | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | |
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Resistance | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Configuration | |
Configuration software | |
| Yes |
| Yes |
Functionality under WinCC (TIA Portal) | |
Process coupling | |
| Yes; with ET 200pro CPU and ET 200S CPU |
| Yes |
| No |
| Yes; STEP 7 or SIMATIC STEP 7 Basic V11 or higher |
| No |
| Yes |
| No |
| No |
| No |
| No |
| No |
| No |
| No |
| No |
| No |
Mechanics/material | |
Enclosure material (front) | |
| Yes |
| No |
Service life | |
| 1 500 000 |
| 100 % |
Dimensions | |
Width of the housing front | 98 mm |
Height of housing front | 155 mm |
Mounting cutout, width | 68 mm; Max. thickness of mounting plate 2 - 6 mm |
Mounting cutout, height | 129 mm |
Overall depth | 49 mm; Incl. angled SIMATIC Ethernet connector |
Weights | |
Weight without packaging | 270 g |