Mode of operation
Measuring principle
Ultrasonic level measurement
Input
Measuring range
0.25 ... 5 m (0.8 ... 16.4 ft)
Frequency
54 kHz
Output
mA
4 ... 20 mA
Proportional/ inversely proportional
600 ? in the loop at 24 V DC
Power supply
Supply voltage
12 ... 30 V DC, 0.1 A surge
Max. power consumption
0.75 W (25 mA at 24 V DC)
Certificates and approvals
CSA:
IS/ Class I, II, III, Div. 1, Groups: A, B, C, D, E, F, G T4
FM:
ATEX:
II 1G Ex ia IIC T4 Ga IECEx Ex ia IIC T4 GaNEPSI Ex ia IIC T4 Ga
Accuracy
Error in measurement
0.25 % of measuring range (in air)
Resolution
3 mm (0.125 inch)
Temperature compensation
Built in
Echo processing
Sonic Intelligence
Rated operation conditions
Beam angle
12°
Ambient temperature
-40 ... +60 °C (-40 ... +140 °F)
-20 ... +60 °C (-4 ... +140 °F)
Max. static operating pressure
Normal atmospheric pressure
Design
Weight
1.3 kg (2.9 lb)
Material
PBT
PVDF copolymer
Degree of protection
IP68 / NEMA 6 / TYPE 6
Process connection
Flange adapter
3" Universal, (fits DN 65, PN 10 and 3" ASME)
Cable inlet
1 inlet for M20, optional 1/2" NPT