Weighing modes | - Non-automatic scales (filling + removal) (in accordance with OIML R-76)
- Automatic scales for single weighing (filling + removal) (in accordance with OIML R-51)
- Automatic scales for batching (in accordance with OIML R-61)
|
Integration in automation systems | |
S7-1200 | SIMATIC S7-1200 system bus |
Operator panel and/or automation systems from other vendors | Via Ethernet (Modbus TCP/IP) or RS 485 (Modbus RTU) |
Ports | - 1 x SIMATIC S7-1200 system bus
- 1 x Ethernet (SIWATOOL and Modbus TCP/IP)
- 1 x RS 485 (Modbus RTU or remote display)
- 1 x analog output (0/4 ... 20 mA)
- 4 x digital inputs (24 V DC, floating)
- 4 x digital outputs (24 V DC, floating, short-circuit proof)
|
Functions | - 3 limits
- Tare
- Tare specification
- Set to zero
- Zero adjustment
- Statistics
- Automatic correction of the shut-off points
- Internal protocol memory for 550 000 entries
- Trace function for signal analysis
- Internal restore point
- Stand-alone mode or SIMATIC S7-1200 integrated
|
Parameter assignment | - Full access using function block in SIMATIC S7-1200
- Full access using Modbus TCP/IP
- Full access using Modbus RTU
|
Remote display | |
Connection | via RS 485 |
Setting the scales | PC software SIWATOOL (Ethernet), S7-1200 function block and touch panel or directly connected operator panel (Modbus) |
Measuring accuracy | |
Error limit according to DIN 1319-1 of full-scale value at 20 °C ± 10 K (68 °F ± 10 K) | 0.05% |
Internal resolution | Up to ±4 million parts |
Number of measurements/second | 100 or 120 (selectable) |
Filter | - Low-pass filter 0.1 ... 50 Hz
- Average value filter
|
Load cells | Full-bridge strain gauges in 4-wire or 6-wire system |
Load cell powering | |
Supply voltage (regulated via feedback) | 4.85 V DC |
Permissible load resistance | |
| > 40 ? |
| < 4 100 ? |
With SIWAREX IS Ex interface | |
| > 50 ? |
| < 4 100 ? |
Load cell characteristic | 1 … 4 mV/V |
Permissible range of the measurement signal (with 4 mV/V sensors) | -21.3 ... +21.3 mV |
Max. distance of load cells | 500 m (229.66 ft) |
Connection to load cells in Ex zone 1 | Optionally via SIWAREX IS Ex interface |
Certificates | |
Auxiliary power supply | |
Rated voltage | 24 V DC |
Max. power consumption | 200 mA |
Max. power consumption SIMATIC Bus | 3 mA |
IP degree of protection according to DIN EN 60529; IEC 60529 | IP20 |
Climatic requirements Tmin(IND) ... Tmax(IND) (operating temperature) | |
| -10 ... +40 °C (14 ... 104 °F) |
| -10 ... +55 °C (14 ... 131 °F) |
EMC requirements | according to EN 45501 |
Dimensions | 70 x 75 x 100 mm (2.76 x 2.95 x 3.94 in) |