SIWAREX WL230 SB-S CA
Possible applications
Model
Loads
Minimum initial loading Emin
0 kg
Max. working load Lu
150% Emax.
Break load Ld
300% Emax.
Safe lateral load LIq
100% Emax
Accuracy class OIML R60
OIML C3
OIML C4
OIML C5
Rated load/maximum load Emax.
100 kg, 250 kg, 500 kg, 1 000 kg, 2 000 kg, 3 000 kg 5 000 kg, 10 000 kg
(220.46 lb, 551.16 lb, 1 102.31 lb, 2 204.62 lb, 4 409.25 lb, 6 613.87 lb, 11 023.11 lb, 22 046.23 lb)
100 kg, 250 kg, 500 kg, 1 000 kg, 2 000 kg
(220.46 lb, 551.16 lb, 1 102.31 lb, 2 204.62 lb, 4 409.25 lb)
3 000 kg, 5 000 kg, 10 000 kg
(6 613.87 lb, 11 023.11 lb, 22 046.23 lb)
Max. load cell verification intervals nLC
3 000
4 000
5 000
Min. load cell verification intervals Vmin
Emax/10 000
Emax/15 000
Emax/20 000
Emax/18 000
Measurement characteristic values
Combined error Fcomb
? ± 0.023% Cn
? ± 0.018% Cn
? ± 0.014% Cn
Recommended supply voltage
5 ... 12 V DC
Maximum supply voltage
18 V DC
Rated characteristic value Cn
3.0 ± 0.003 mV/V
Tolerance Do of zero signal
? ± 1.0% Cn
Creep error 30 min Fcr
? ± 0.015% Cn
Electrical characteristic values
Input resistance Re
350 ± 3.5 ?
Output resistance Ra
Insulation resistance Ris
? 5 000 M? at 50 V DC
Connection and ambient conditions
Rated temperature range Btn
-10 ... +40 °C (14 ... 104 °F)
Operating temperature range Btu
-35 ... +65 °C (-31 ... 149 °F)
Storage temperature range Bts
-40 ... +80 °C (-40 ... 176 °F)
Sensor material (DIN)
Steel, nickel-plated
Degree of protection acc. to EN 60529
IP67
Rated measuring path n at Emax
Recommended tightening torque of the fixing screws
Length of the connecting cable (four-core)
Diameter of the connecting cable
5 mm
Color coding of the connecting cable
Color
ATEX
-