Central Interface Module (CIM)CommunicationPROFINET - Import of parameter settings from the higher-level control system
- Transfer of diagnostic information to the higher-level control system
Serial bus (internal) - Control and monitoring of up to 54 power channels
Performance features- Calculation of manipulated variables of power channels
- Setpoints can be adjusted from 0% to 100% in increments of 1%
- Even load distribution over all power channels and over all SIPLUS HCS4300 heating control systems operated as an integrated group
- Simple adaptation to any production process through the selection of operating modes
- Diagnostics functions
- Evaluation of diagnostics information from connected power output modules
- Phase-sequence detection indicating whether phases L1, L2, and L3 are correctly connected
- Automatic detection of the line frequency
|
|