| | IPC547E (enclosure depth 356 mm) | IPC547E (enclosure depth 446 mm) |
General features | | |
Design | 19" rack PC, 4 U |
Processors | - Intel Pentium Dual Core G3420
(2C/2T, 3.2 GHz, 3 MB cache) - Intel Celeron G1820
(2C/2T, 2.7 GHz, 2 MB cache)
| - Intel Core i7-4770S
(4C/8T, 3.1 (3.9) GHz, 8 MB cache, iAMT) - Intel Core i5-4570S
(4C/4T, 2.9 (3.6) GHz, 6 MB cache, iAMT) - Intel Pentium Dual Core G3420
(2C/2T, 3.2 GHz, 3 MB cache)
|
Chipset | | |
Main memory | - From 2 GB DDR3-1600 SDRAM
- Dual channel support
- 2 DIMM base
- Expandable up to 16 GB 1)
| - From 2 GB DDR3-1600 SDRAM
- Dual channel support
- 4 DIMM base
- Expandable up to 32 GB 1)
|
Spare slots for expansions (all long) | - 1 x PCI Express x16
- 1 x PCI-Express x16 (2 lanes)
- 1 x PCI-Express x8 (1 lane)
- 4 x PCI
| - 1 x PCI Express x16
- 1 x PCI-Express x16 (4 lanes)
- 1 x PCI-Express x8 (1 lane)
- 4 x PCI
|
Graphics | - Onboard Intel HD / Intel HD Graphics 4600 graphics controller integrated into the processor
Dynamic video memory up to 1.7 GB; up to 3840 x 2160 pixels at 60 Hz image refresh rate and 32-bit colors - PCI Express graphics card (Dual Head: 2 x VGA or 2 x DVI-D) in the PCIe x16 slot (optional), 512 MB;
up to 2048 x 1536 pixels at 60 Hz image refresh rate and 32-bit colors
|
Operating systems | Preinstalled and activated (supplied on restore DVD): - Windows 7 Ultimate MUI (32/64-bit)
MUI (Multi-Language User Interface, 5 languages): English, German, French, Italian, Spanish Project-specific on request: | Preinstalled and activated (supplied on restore DVD): - Windows 7 Ultimate MUI (32/64-bit)
- Windows Server 2008 R2 incl. 5 Client MUI (64-bit)
- Windows Server 2012 R2 incl. 5 Client MUI (64 bit)
MUI (Multi-Language User Interface, 5 languages): English, German, French, Italian, Spanish Project-specific on request: |
Power supplies | - 100 ... 240 V AC, 50 ... 60 Hz, with bridging of short-term power failures: max. 20 ms at 0.85 % rated voltage
| - 100 ... 240 V AC, 50 ... 60 Hz, with bridging of short-term power failures: max. 20 ms at 0.85 % rated voltage
- Redundant 2 x 100 ... 240 V AC, 50 ... 60 Hz
|
Drives | | |
Hard disks, SATA 3.5" with NCQ technology Solid-state drives, SATA 2.5" with MLC technology | Internal installation - 1 x 500 GB HDD
- 1 x 1 TB HDD
- 2 x 1 TB HDD
| Internal installation - 1 x 500 GB HDD
- 1 x 1 TB HDD
- 2 x 1 TB HDD
- 1 x 240 GB SSD
- RAID1, 1 TB (2 x 1 TB HDD, mirror disks) 3)
Installation at the front in removable drive bay (low-profile) - 1 x 500 GB HDD
- 1 x 1 TB HDD
- 2 x 1 TB HDD
- 1 x 240 GB SSD
- RAID1, 1 TB (2 x 1 TB HDD, mirror disks), "hot swap" 3)
- RAID1, 1 TB (2 x 1 TB HDD, mirror disks), "hot swap" 3)
+ 1 x 1 TB HDD as hot spare - RAID1, 1 TB (2 x 1 TB HDD, mirror disks), "hot swap" 3)
+ 1 x 240 GB SSD (operating system installed on SSD if configured) - RAID5, 2 TB (3 x 1 TB HDD, striping with parity), "hot swap" 3)
- RAID5, 2 TB (3 x 1 TB HDD, striping with parity), "hot swap" 3)
+ 1 x 1 TB HDD as hot spare
|
DVD±R/RW, 5.25" (slim), SATA | - | - 8 x 8 x 6 x (DVD media)
- 24 x 10 x 16 x (CD media)
|
Slots for drives | Internal: | Front: - 3 x 5.25" / 4 x low-profile removable drive bay
- 1 x 5.25" (slimline)
Internal: |
Interfaces | | |
Ethernet | 1 x Intel Gigabit Ethernet (RJ45) | 2 x Intel Gigabit Ethernet (RJ45, teaming-capable) |
USB 3.0 | | - 2 x front (high current)
- 2 x rear (high current)
|
USB 2.0 | | - 6 x rear (high current)
- 1 x internal (high current), e.g. for USB dongle with optional interlocking
|
Serial | 9-pin COM2 (V.24) (optional) | 9-pole COM1 (V.24); COM2 (V.24) (optional) |
Parallel | LPT (optional) |
VGA | Optionally via adapter cable |
DVI-I | 1 x |
DisplayPort V1.2 | 1 x | 2 x |
PS/2 | 2 x (keyboard, mouse) |
Audio | 1 x line in; 1 x line out; 1 x mic. |
Monitoring functions | |
Basic functionality | Message locally via DiagBase software |
Temperature | When permitted operating temperature range is exceeded |
Fans | Speed monitoring - 1 x front fan
- 1 x CPU fan
- 1 x power supply fan
|
Watchdog | - Monitoring of program execution
- Monitoring time can be parameterized in software
|
Monitoring functions via the network | SIMATIC IPC DiagMonitor Version V4.4.x.x or higher (optional) Remote monitoring capability for: - Watchdog
- Temperature
- Fan speed
- Battery
- Hard disks (SMART)
- System/Ethernet
Communication: - Ethernet interface (SNMP protocol)
- OPC for integration in SIMATIC software
- Client server architectures
- Structure of log files
|
Front LEDs | - POWER (PC switched on)
- HDD (access to hard disk)
- TEMP (temperature monitoring)
- FAN (fan monitoring)
|
Environmental conditions | |
Degree of protection | IP30 front, IP20 rear according to EN 60529 |
Dust protection | With the front door closed according to IEC 60529 filter class G2 EN 779, 99% of particles > 0.5 mm are filtered |
Protection class | Protection class I compliant with IEC 61140 |
Vibration load during operation 4) | IEC 60068-2-6, 10 cycles - 20 ... 58 Hz: 0.015 mm
- 58 ... 200 Hz: 2 m/s2 (approx. 0.2 g)
|
Shock load in operation 4) | IEC 60068-2-27 - Half sine: 9.8 m/s2, 20 ms (approx. 1 g), 100 shocks per axis
|
Electromagnetic compatibility (EMC) | |
Emitted interference | EN 61000-6-3; EN 61000-6-4; CISPR 22 / EN 55022 Class B; FCC Class A; EN 61000-3-2 Class D; EN 61000-3-3 |
Immunity to conducted interference on supply lines | - ±2 kV (IEC 61000-4-4, burst)
- ±1 kV (IEC 61000-4-5, symm. surge)
- ±2 kV (IEC 61000-4-5, asymm. surge)
|
Noise immunity on signal lines | - ±2 kV (IEC 61000-4-4, burst, length > 30 m)
- ±1 kV (IEC 61000-4-4, burst, length < 30 m)
- ±2 kV (IEC 61000-4-5, surge, length > 30 m)
|
Immunity to static discharge | - ±4 kV, contact discharge (IEC 61000-4-2)
- ±8 kV, air discharge (IEC 61000-4-2)
|
Immunity to high-frequency radiation | - 10 V/m; 80 to 1000 MHz, 80 % AM (IEC 61000-4-3)
- 3 V/m; 1.4 to 2 GHz, 80 % AM (IEC 61000-4-3)
- 1 V/m, 2 to 2.7 GHz, 80 % AM (IEC 61000-4-3)
- 10 V, 150 kHz to 80 MHz, 80 % AM (IEC 61000-4-6)
|
Immunity to magnetic fields | 30 A/m, 50/60 Hz (IEC 61000-4-8) |
Ambient temperature during operation | 5 ... 40 °C | 5 ... 40 °C Note: Limitations for operation of DVD±R/RW |
Humidity during operation | 5 ... 80 % at 25 °C (no condensation) |
Approvals and safety regulations | |
Safety directives | IEC 60950-1; UL60950; CSA |
Approvals | cULus 60950 |
CE marking | For use in industrial areas as well as domestic, business and commercial environments: - Emitted interference: EN 61000-6-3:2007
- Noise immunity: EN 61000-6-2:2005
|
Dimensions and weights | |
Installation dimensions (W x H x D) in mm | 434 x 177 x 356 | 434 x 177 x 446 |
Weight, approx. | 15 kg | 19 kg |