Mechanical specifications |
Vibratory load | |
- Transport acc. to EN 60721?3?2 1)
| Class 1M2 |
- Operation acc. to EN 60721?3?3
| Class 3M3 |
Shock load | |
- Transport acc. to EN 60721?3?2 1)
| Class 1M2 |
- Operation acc. to EN 60721?3?3
| Class 3M3 |
Ambient conditions | |
Protection class according to EN 61800?5?1 | Class III (PELV) |
Touch protection according to EN 61800?5?1 | Class I (with protective conductor system) |
Permissible ambient and coolant temperature (air) during operation for Power Modules | -10 ... +40 ? (14 ... 104 °F) without derating >40 ... 55 ? (104 ... 131 °F) see derating characteristics |
Permissible ambient and coolant temperature (air) during operation for Control Units | -10 ... +55 °C (14 ... 131 °F) without derating |
Humidity, max. | 95 % at 40 °C (104 °F) |
Ambient temperature | |
- Storage 1) acc. to EN 60068?2?1
| -40 ... +70 °C (-40 ... +158 °F) |
- Transport 1) acc. to EN 60068?2?1
| -40 ... +70 °C (-40 ... +158 °F) |
- Operation acc. to EN 60068?2?2
| -10 ... +40 ? (14 ... 104 °F) without derating |
Environmental class/harmful chemical substances | |
Operation acc. to EN 60721?3?3 | Class 3C2 |
Degree of pollution acc. to EN 61800?5?1 | 2 |
Certification for fail-safe versions |
| SIL 2 |
- According to EN ISO 13849?1
| PL d and Category 3 |
Standards |
Compliance with standards | UL, cUL, CE, C-Tick (RCM) |
CE marking, according to | Low-Voltage Directive 2006/95/EC |
EMC Directive 2) | |
- Frame sizes FSA to FSC with integrated line filter class A
| Category C2 3) according to EN 61800?3 |
| | Note: The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter. The frequency inverters on their own do not generally require identification according to the EMC Directive. |