Possible applications | |
| | |
| | |
Model | Platform load cell |
Loads | |
Rated load Emax | |
| | |
| | |
| | |
| | |
Minimum initial loading Emin | 0% Emax |
Maximum working load Lu | 150 % Emax |
Ultimate load Ld | 300% Emax |
Maximum lateral load Llq | 100% Emax |
Measurement characteristic values | |
Rated measuring path hn with | |
| 0.24 ± 0.02 mm (0.009 ± 0.0008 in) |
| 0.19 ± 0.01 mm (0.008 ± 0.0004 in) |
| 0.15 ± 0.01 mm (0.006 ± 0.0004 in) |
| 0.22 ± 0.03 mm (0.009 ± 0.0011 in) |
Rated characteristic value Cn | 2.0 ± 0.2 mV/V |
Tolerance DO of zero signal | < ± 2.0% Cn |
Maximum scale interval nlc | 3 000 |
Min. interval Vmin with | |
- Emax = 6, 12, 30, 60 kg (13.23, 26.46, 66.14, 132.28 lb)
| Emax/15 000 |
Combined error Fcomb | ? ± 0.02% Cn |
Repeatability Fv | ? ± 0.02% Cn |
Creep error Fcr | |
30 min | ? ± 0.025% Cn |
Temperature coefficient | |
| 0.009% Cn/10 °C (50 °F) |
| 0.009% Cn/10 °C (50 °F) |
Electrical characteristic values | |
Recommended reference voltage Uref | 5 … 12 V DC |
Input resistance Re | 400 ? ± 20 ? |
Output resistance Ra | 350 ? ± 3.5 ? |
Insulation resistance Ris | 5 000 M? at 50 V DC |
Connection and environmental conditions | |
Sensor material (DIN) | Stainless steel |
Maximum tightening torque of the fixing screws | 10 Nm |
Cable connection | |
Function | Color |
| green |
| black |
- SIG + (measured signal +)
| white |
- SIG – (measured signal -)
| red |
| yellow |
| blue |
- Shield (not connected to housing)
| transparent |
Rated temperature range Btn | -10 ... +40 °C (14 ... 104 °F) |
Operating temperature range Btu | -35 … +65 °C (-31 ... +149 °F) |
Storage temperature range Bts | -35 … +65 °C (-31 ... +149 °F) |
Degree of protection according to EN 60529; IEC 60529 | IP68 |
Certificates and approvals | |
Accuracy class according to OIML R60 | C3 |