Process media | - Fluid Group 1 (suitable for dangerous fluids)
|
- Aggregate state: Paste/light slurry, liquid and gas
|
Number of process variables | 7 |
Measurement of | |
|
|
- Process media temperature
|
|
|
|
|
|
|
Current output | |
Current | 0 … 20 mA or 4 … 20 mA (Channel 1 only 4 … 20 mA) |
Load | < 500 ? per channel |
Time constant | 0 … 100 s adjustable |
Digital output1) | |
Pulse | 41.6 ?s … 5 s pulse duration |
Frequency | 0 … 10 kHz, 50 % duty cycle, 120 % overscale provision |
Time constant | 0 … 100 s adjustable |
Active | 0 … 24 V DC, 110 mA, short-circuit-protected |
Passive | 3 … 30 V DC, max. 110 mA |
Relay | |
Type | Change-over voltage-free relay contact |
Load | 30 V AC/100 mA |
Functions | Alarm level, alarm number, limit, flow direction |
Digital input | |
Voltage | 15 … 30 V DC (2 … 15 mA) |
Functionality | Start/stop/hold/continue dosing, reset totalizer 1 and 2, force output, freeze output |
Galvanic isolation | All inputs and outputs are galvanically isolated, isolation voltage 500 V. |
Cut-off | |
Low-flow | 0 … 9.9 % of maximum flow |
Limit function | Mass flow, volume flow, fraction, density, sensor temperature |
Totalizer | Three eight-digit counters for forward, net or reverse flow |
Display | - Background illumination with alphanumerical text, 3 x 20 characters to indicate flow rate, totalized values, settings and faults.
|
- Time constant as current output 1
|
- Reverse flow indicated by negative sign
|
Zero point adjustment | Via keypad or remote via digital input |
Ambient temperature | |
Operation | |
| -40 … +60 °C (-40 … +140 °F), (humidity max. 95 %) |
| -20 … +60 °C (-4 … +140 °F) |
Storage | |
| -40 … +70 °C (-40 … +158 °F), (humidity max. 95 %) |
| -20 … +70 °C (-4 … +158 °F) |
Communication | HART 7.2 |
Enclosure | |
Material | Aluminum |
Rating | IP67/NEMA 4X to IEC 529 and DIN 40050 (1 mH2O for 30 min.) |
Mechanical load | 18 … 400 Hz random, 3.17 g RMS, in all directions |
Supply voltage | |
Supply | 20 ... 27 V DC ± 10%; 100 ... 240 V AC ± 10 %, 47 ... 63 Hz |
Fluctuation | No limit |
Power consumption | 7.5 W/15 VA |
EMC performance | |
Emission | EN 55011/CISPR-11 (Class A) |
Immunity | EN/IEC 61326-1 (Industry) |
NAMUR | Within the value limits according to "General requirements" with error criteria A in accordance with NE 21 |
Environment | Within the value limits according to "General requirements" with alarm criteria A in accordance with NE 21 |
Environmental conditions acc. to IEC/EN/UL 61010-1 | |
|
Maintenance | The flowmeter has a built-in error log/pending menu which should be inspected on a regular basis. |
Cable glands | Cable gland are available in Nylon, Nickel plated brass or stainless steel (316L/W1.4404) in the following dimensions: |
|
|
Cable | Standard industrial signal cable up to 200 m long with 2 x screened pairs or 4-wire overall screen can be laid between the sensor and transmitter. Siemens offers cables in a selection of precut lengths and prepared for either gland or plug connection. |
Approvals | |
Hazardous area | ATEX, IECEx, EAC Ex, FM, CSA, NEPSI, INMETRO: |
- Zone 1: Ex d e ia [ia Ga] IIC T6 Gb
|
- Zone 21: Ex tb [ia Da] IIIC T85°C Db
|
FM: |
- Class I+II+III, Div. 1 (US only): Grp. A, B, C, D, E, F, G, H
|
Custody transfer | - OIML R 117 type approval to a wide variety of liquids other than water
|
|
Pressure equipment | |
|
Hygienic applications | - EHEDG for hygienic variant sensors
|
- 3A for hygienic variant sensors
|
- External cleanability satisfies EHEDG and 3A rules
|
Certificates | |
Safety Integration Level (applies only to compact versions) | |
|
- SIL 3 for redundant hardware systems
|
CE mark | |
|
|
|
Regional certifications | - C-TICK (Australia and New Zealand EMC)
|
- EAC (Belarus, Armenia, Kazakhstan, Russia)
|
|