General information | |
Weight | Max. 5.2 kg (standard version) |
Measuring ranges | |
Number of measuring ranges | Max. 4; parameters can be assigned freely |
Parameters can be assigned in the measuring ranges | |
| CO: 0 ... 10 vpm CO2: 0 ... 5 vpm CH4: 0 ... 50 vpm C2H4: 0 ... 300 vpm SO2: 0 ... 50 vpm NO: 0 ... 100 vpm N2O: 0 ... 50 vpm NH3: 0 ... 100 vpm |
- Largest possible measuring span
| CO: 0 to 100% CO2: 0 to 100% CH4: 0 to 100% C2H4: 0 to 100% SO2: 0 ... 100% NO: 0 ... 30 000 vpm N2O: 0 to 100% NH3: 0 to 100% |
Gas inlet conditions | |
Sample gas pressure | |
- Standard pressure (atmospheric pressure compensation)
| 500 to 1 500 hPa (absolute) |
Pressure drop between sample gas inlet and sample gas outlet | < 10 hPa at 1.5 l/min |
Sample gas flow | 18 … 90 l/h (0.3 … 1.5 l/min) |
Sample gas temperature | 0 to 50 °C |
Sample gas humidity (rel. humidity) | < 90% (condensation inside the gas path is to be avoided) |
Dynamic response | |
Warm-up period at room temperature | < 2 h |
Response characteristics | |
| Application-specific (max. 3.6 s) |
- Signal rise time (Tr) or fall time (Tf) with application-specific electronic damping of 10 s
| Application specific < 14 s |
- Time for device-internal signal processing Tv
| Approx. 1 s |
| Rule: T90 < T10 + Tr/f + Tv |
Measuring response | |
Output signal fluctuation | ? ± 1% of smallest measuring range acc. to nameplate |
Zero point drift | < ± 1 %/week of smallest measuring range acc. to nameplate |
Measured-value drift | ? 1% of the current measuring range per week |
Repeatability | ? ± 1% of the current full-scale value |
Linearity error | < ± 0.5% of the current full-scale value |
Influencing variables | |
Ambient temperature | |
| ? 1% of the current measuring range/10 K (at constant receiver cell temperature) |
Sample gas pressure | |
- Without pressure compensation
| < 1.5% of the current measuring range/1% pressure variation |
- With pressure compensation switched on
| < 0.15% of the current measuring range/1% pressure variation |
Sample gas flow | ? 1% of the current full-scale value/0.1 l/min change in flow |
Supply voltage | ? 0.1% of the current measuring range (with the nominal range of use) |
Electrical outputs | |
Analog and digital interfaces | See base unit |
Climatic conditions | |
Storage and transport | -30 to 70 °C |
Permissible ambient temperature (during operation in base unit)1) | 5 to 45 °C |
Relative humidity (RH) during storage, transport or operation | < 90% (condensation from the installed components is to be avoided) |
Gas connections | |
Connection fittings | Pipe connection with 6 mm outer diameter |
Materials of wetted parts | |
Bushing | Stainless steel, mat. no. 1.4571 |
Pipe | Stainless steel, mat. no. 1.4571, O-ring: FKM (e.g. Viton) or FFKM (Kalrez) |
Sample chamber | |
| Aluminum |
| Aluminum |
| CaF2, adhesive: E353, O-ring: FKM (e.g. Viton) |