Application | |
Gauge and absolute pressure measurement | Liquids, gases and vapors |
Mode of operation | |
Measuring principle | Piezo-resistive measuring cell (ceramic diaphragm) |
Measured variable | Gauge and absolute pressure |
Input | |
Measuring range | |
| |
| 1 … 60 bar (15 … 870 psi) |
| 15 … 1000 psi |
| |
| 0.6 … 16 bar a (10 … 232 psia) |
| 10 … 300 psia |
Output | |
Current signal | 4 ... 20 mA |
| (UB - 10 V) / 0.02 A |
| 7 ... 33 V DC (10 ... 30 V for Ex) |
Voltage signal | 0 ... 10 V DC |
| ? 10 k? |
| 12 ... 33 V DC |
| < 7 mA at 10 k? |
Radiometric output | 10 ... 90 % |
| ? 10 k? |
| 5 V DC ± 10 % |
| < 7 mA at 10 k? |
Characteristic curve | Linear rising |
Measuring accuracy | |
Error in measurement at limit setting including hysteresis and reproducibility | - Typical: 0.25 % of full-scale value
- Maximum: 0.5 % of full-scale value
|
Step response time T99 | < 5 ms |
Long-term stability | |
- Lower range value and measuring span
| 0.25 % of full-scale value/year |
Effect of ambient temperature | |
- Lower range value and measuring span
| 0.25 %/10 K of full-scale value |
- Influence of power supply
| 0.005 %/V |
Rated conditions | |
Pressure transmitter with gasket made of: | |
| -15 ... +125 °C (5 ... 257 °F) |
| -35 ... +100 °C (-31 ... +212 °F) |
| -20 ... +100 °C (-4 ... +212 °F) |
| -40 ... +145 °C (-40 ... +293 °F), usable for drinking water |
Ambient temperature | -25 ... +85 °C (-13 ... +185 °F) |
Storage temperature | -50 ... +100 °C (-58 ... +212 °F) |
Degree of protection according to IEC 60529 | - IP65 with connector to EN 175301-803-A
- IP67 with M12 connector
- IP67 with cable
- IP67 with cable quick screw connection
|
Electromagnetic compatibility | - according to IEC 61326-1/-2/-3
- according to NAMUR NE21 for ATEX devices only, and with a max. measurement error of ? 1 %
|
Design | |
Weight | Approx. 0.090 kg (0.198 lb) |
Process connections | See dimension drawings |
Electrical connections | - Connector per EN 175301-803-A Form A with cable inlet M16x1.5 or ?-14 NPT or Pg 11
- M12 connector
- 2 or 3-wire (0.5 mm2) cable (? ± 5.4 mm)
- Quickon cable quick screw connection
|
Wetted parts materials | |
| AI2O3 - 96 % |
| Stainless steel, mat. no. 1.4404 (SST 316 L) |
| - FPM (standard)
- Neoprene
- Perbunan
- EPDM
|
Non-wetted parts materials | |
| Stainless steel, mat. no. 1.4404 (SST 316 L) |
| Plastic |
| PVC |
Certificates and approvals | |
Classification according to pressure equipment directive (PED 2014/68/EU) | For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of article 4, paragraph 3 (sound engineering practice) |
Lloyd's Register of Shipping (LR)* | 12/20010 |
Germanischer Lloyd (GL)* | GL19740 11 HH00 |
American Bureau of Shipping (ABS)* | ABS_11_HG 789392_PDA |
Bureau Veritas (BV)* | BV 271007A0 BV |
Det Norske Veritas (DNV)* | A 12553 |
Drinking water approval (ACS)* | ACS 15 ACC NY 360 |
EAC* | № TC RU C-DE.ГБ05.В.00732 OC НАНИО «ЦСВЭ» |
Underwriters Laboratories (UL)* | |
| UL 20110217 - E34453 |
| IEC UL DK 21845 |
Explosion protection | |
Intrinsic safety "i" (only with current output) | Ex II 1/2 G Ex ia IIC T4 Ga/Gb Ex II 1/2 D Ex ia IIIC T125 °C Da/Db |
EC type-examination certificate | SEV 10 ATEX 0146 |
Connection to certified intrinsically-safe resistive circuits with maximum values | Ui ? 30 V DC; Ii = 100 mA; Pi ? 0.75 W |
Effective internal inductance and capacity for versions with plugs per EN 175301-803-A and M12 | Li = 0 nH; Ci = 0 nF |