General information | |
Product brand name | SIPLUS |
Product designation | IFN VIB-ACC |
Product description | Six IEPE sensor signals or five IEPE sensor signals and one analog input signal (e.g. for speed) are measured with the IFN VIB-A. |
Installation type/mounting | |
Mounting type | standard rail |
Mounting accessories | Mounting bracket, can be ordered as option |
Required clearance | |
| 25 mm |
| 80 mm |
| 25 mm |
Supply voltage | |
Type of power supply | stabilized |
Supply voltage (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 32 V |
Reverse polarity protection | Yes |
Overvoltage protection | max. 35 V |
Input current | |
from external supply (24 V DC), max. | 0.2 A |
Power | |
Active power input, max. | 4.8 W |
Analog inputs | |
Number of analog inputs | 1 |
Designation of the analog input | CH6 |
Measured variable | Voltage |
Connector type | Connector plug 5-pole (M12) |
Electrical input frequency, min. | 0 Hz |
Electrical input frequency, max. | 1 kHz |
Overvoltage strength, min. | -60 V |
Overvoltage strength, max. | 60 V |
Short-circuit detection | No |
Input ranges (rated values), voltages | |
| -30 V |
Input ranges (rated values), currents | |
| 0.012 mA |
Analog value generation for the inputs | |
Parameterizable down sampling frequencies | 4 / 8 / 16 / 24 / 48 / 64 / 96 kHz |
Sampling frequency, max. | 192 kHz |
Integration and conversion time/resolution per channel | |
| 16 bit |
Sensor input | |
Number of sensor inputs | 6 |
Designation of the sensor inputs | CH1 ... CH6 |
Design of the sensor | IEPE |
Overvoltage strength, min. | -60 V |
Overvoltage strength, max. | 60 V |
Short-circuit detection | Yes |
Encoder signals, IEPE | |
| 0.1 Hz |
| 40 kHz |
| 0.014 / 0,33 / 4 / 8 / 16 / 24 / 48 / 64 / 96 kHz |
| 16 bit |
Errors/accuracies | |
Relative measuring accuracy for analog input signals, min. | -1 % |
Relative measuring accuracy for analog input signals, max. | 1 % |
Relative measuring accuracy for IEPE signals, min. | -0.7 % |
Relative measuring accuracy for IEPE signals, max. | 0.7 % |
Crosstalk attenuation between analog input signals at 1 kHz | -78 dB |
Crosstalk attenuation between sensor channels CH 1 and CH 2 at 1 kHz | -69 dB |
Crosstalk attenuation between sensor channels CH 3 ... CH 6 at 1 kHz | -73 dB |
Signal-to-noise ratio for analog input signals | -69 dB |
Signal-to-noise ratio between sensor channels CH 1 and CH 2 for IEPE signals | -57 dB |
Signal-to-noise ratio between sensor channels CH 3 ... CH 6 for IEPE signals | -70 dB |
Interfaces | |
Number of interfaces | 3 |
Transmission rate | 400 Mbit/s |
Protocols | |
Protocol | IEEE 1394a/b |
Potential separation | |
Potential separation analog inputs | |
| No |
Galvanic isolation at sensor input | |
| No |
Degree and class of protection | |
IP degree of protection | IP67 |
Standards, approvals, certificates | |
Certificate of suitability | CE |
Ambient conditions | |
Ambient temperature during operation | |
| -40 °C |
| 65 °C |
Ambient temperature during storage/transportation | |
| -40 °C |
| 85 °C |
| -40 °C |
| 85 °C |
Connection method | |
Design of electrical connection for the PE conductor | M4 screw with contact washer |
| 2.5 mm? |
Design of plug-in connection | Connector plug 8-pole (M12) |
Design of the pin assignment of the inputs | Male connector 5-pole (M12) |
Mechanics/material | |
Material of housing | aluminum |
Dimensions | |
Width | 86 mm |
Height | 210 mm |
Depth | 87 mm |
Width when mounted on DIN rail | 86 mm |
Height when mounted on DIN rail | 210 mm |
Depth when mounted on DIN rail | 96 mm |
Weights | |
Weight (without packaging) | 1.24 kg |